Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} — CEC Inverter Specifications

Manufacturer: Fronius International GmbH Registry: CEC Verified Engineering Specification

Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} outputs 6,000 W AC at 208 V, commercial single-phase (28.8 A continuous, 40 A OCPD), ranking #699 of 2,343 CEC inverters at 97.27% efficiency with a 100-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
6,000 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
97.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} Compare Against Peer CEC Listings?

How Fronius International GmbH Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} compares on 97.27% efficiency, MPPT span, and 120% busbar interconnection.

With a 100-800 V MPPT tracking band and 800 V DC ceiling, Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} handles 6,000 W continuous AC (1,000 W above the 5,000 W 208 V median). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Installers comparing Fronius International GmbH against ABB: PVI-6000-OUTD-US-A {208V} (6,000 W) should verify whether listed since 2019-03-01 grid-support firmware meets local IEEE 1547 utility rules.

Where Does Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} Fall Across Listed CEC Models?

Position of Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} (6,000 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} (6,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFronius Internatio: 6,000 W

What Dataset Percentiles Define Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}?

Percentile placement of Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} across AC power class, conversion efficiency, and backfeed breaker size.

Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} Technical ThresholdsPercentile comparison for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output6,000 WCEC Efficiency97.27%Backfeed Breaker40 A

What Do the Dataset Ranks Show for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}.

Eff #699 / 2,343

97.27% CEC Weighted Efficiency

+0.86 pts vs the 96.41% 208 V median; overall power rank #1,387 (6,000 W, below CEC median; higher than 39.4% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 28.8 A = 36.0 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

100 V - 800 V (Max 800 V DC)

Tracking span of 700.0 V; listed since 2019-03-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 6000.0W / 208 V -> 28.8 A | Breaker >= 1.25 * 28.8 = 36.0 A -> 40 A

CEC Inverters.csv for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}: Paco=6000.0 W, Vac=208 V, Vdcmax=800.0 V, Eff=97.27%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 6,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 9.34561 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.27% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-03-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} (208 V, commercial single-phase)?

Check whether Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} (40 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} (40 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 40 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 40 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 40 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 40 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 40 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}?

Verified cold-weather (-10 C) series module counts matched to Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}'s 800 V DC ceiling.

Sampled CEC PV modules aligned within 100.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 18 panels 7.92 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 17 panels 7.22 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 19 panels 3.8 kW

Which Competing Grid-Support Inverters Compare to Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}?

Alternative CEC inverters comparable to Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}, including ABB: PVI-6000-OUTD-US-A {208V} (6,000 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-6000-OUTD-US-A {208V}
ABB
6,000 W Tie (0 W) 208.0 V 480.0 V 95.73%
ABB: PVI-6000-OUTD-US-Z-A {208V}
ABB
6,000 W Tie (0 W) 208.0 V 480.0 V 95.73%
ABB: PVI-6000-OUTD-US-Z-M-A {208V}
ABB
6,000 W Tie (0 W) 208.0 V 480.0 V 95.73%
ABB: UNO-DM-60-TL-PLUS-US-S-XRA {208V}
ABB
6,000 W Tie (0 W) 208.0 V 480.0 V 96.57%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}?

Check Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} (6,000 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Fronius International GmbH: Fronius Primo 60-1 208-240 {208V}.

Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (28.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.27%) and MPPT window (100-800 V) directly against ABB: PVI-6000-OUTD-US-A {208V} (6,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} by Fronius International GmbH covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} require?

At 6,000 W continuous AC (208 V, commercial single-phase), continuous current is 28.8 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} require?

At 6,000 W AC and 208 V, commercial single-phase, continuous line current is 28.8 A, requiring a 40 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} compare to ABB: PVI-6000-OUTD-US-A {208V}?

Fronius International GmbH: Fronius Primo 60-1 208-240 {208V} delivers 6,000 W AC at 97.27% CEC efficiency with a 800 V DC ceiling, while ABB: PVI-6000-OUTD-US-A {208V} outputs 6,000 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.