Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Fortress Power LLC: FP-Envy Duo 21 {240V} — CEC Inverter Specifications

Manufacturer: Fortress Power LLC Registry: CEC Verified Engineering Specification

Fortress Power LLC: FP-Envy Duo 21 {240V} outputs 16,153 W AC at 240 V (67.3 A continuous, 90 A OCPD), ranking #1,348 of 2,343 CEC inverters at 96.61% efficiency with a 250-440 V MPPT window and 440 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
16,153 W
AC Voltage
240 V
Min PV Breaker
90 A (3 AWG Cu)
CEC Efficiency
96.61%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Fortress Power LLC: FP-Envy Duo 21 {240V} Compare Against Peer CEC Listings?

Breaker sizing (90 A), 3 AWG Cu wire rules, and DC input limits for Fortress Power LLC: FP-Envy Duo 21 {240V}.

For NEC 705.12 solar interconnection, Fortress Power LLC: FP-Envy Duo 21 {240V} outputs 67.3 A continuous AC at 240 V and needs a 90 A backfeed breaker on 3 AWG Cu (75 C). Its 90 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 96.61% (#1,348 of 2,343, -0.21 pts vs overall CEC median).

Where Does Fortress Power LLC: FP-Envy Duo 21 {240V} Fall Across Listed CEC Models?

Output power comparison showing where Fortress Power LLC: FP-Envy Duo 21 {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Fortress Power LLC: FP-Envy Duo 21 {240V} (16,153 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFortress Power LLC: 16,153 W

What Dataset Percentiles Define Fortress Power LLC: FP-Envy Duo 21 {240V}?

Relative ranking of Fortress Power LLC: FP-Envy Duo 21 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Fortress Power LLC: FP-Envy Duo 21 {240V} Technical ThresholdsPercentile comparison for Fortress Power LLC: FP-Envy Duo 21 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output16,153 WCEC Efficiency96.61%Backfeed Breaker90 A

What Do the Dataset Ranks Show for Fortress Power LLC: FP-Envy Duo 21 {240V}?

Snapshot of Fortress Power LLC: FP-Envy Duo 21 {240V} efficiency rank (#1,348), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,348 / 2,343

96.61% CEC Weighted Efficiency

-0.07 pts vs the 96.68% 240 V median; overall power rank #654 (16,153 W, top 28.0%; higher than 72.0% of peers).

NEC 705.12 Check

90 A Required Backfeed OCPD

125% x 67.3 A = 84.1 A -> 90 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

250 V - 440 V (Max 440 V DC)

Tracking span of 190.0 V; listed since 2026-01-12 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 16153.0W / 240 V -> 67.3 A | Breaker >= 1.25 * 67.3 = 84.1 A -> 90 A

CEC Inverters.csv for Fortress Power LLC: FP-Envy Duo 21 {240V}: Paco=16153.0 W, Vac=240 V, Vdcmax=440.0 V, Eff=96.61%.

Result: Min 90 A breaker & 3 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Fortress Power LLC: FP-Envy Duo 21 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Fortress Power LLC: FP-Envy Duo 21 {240V}.

Official California Energy Commission (NREL SAM) test parameters for Fortress Power LLC: FP-Envy Duo 21 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 16,153 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 440 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 250 V - 440 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 46.4447 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.61% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2026-01-12 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Fortress Power LLC: FP-Envy Duo 21 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Fortress Power LLC: FP-Envy Duo 21 {240V} at 240 V.

Evaluates Fortress Power LLC: FP-Envy Duo 21 {240V} (90 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 90 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 90 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 90 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 90 A Needs Derate / Tap 705.11
225A Bus / 200A Main 70 A 90 A Needs Derate / Tap 705.11

Which CEC PV Module Strings Pair With Fortress Power LLC: FP-Envy Duo 21 {240V}?

Minimum and maximum series solar module strings fitting Fortress Power LLC: FP-Envy Duo 21 {240V} MPPT and 440 V limits.

Sampled CEC PV modules aligned within 250.0-440.0 V MPPT and 440.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 9 panels 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 10 panels 2.0 kW

Which Competing Grid-Support Inverters Compare to Fortress Power LLC: FP-Envy Duo 21 {240V}?

Peer 240 V CEC inverters near 16,153 W AC output such as Amensolar Ess Co Ltd: N3H-X16US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X16US {240V}
Amensolar Ess Co Ltd
16,199 W +46 W 240.0 V 430.0 V 96.25%
Amensolar Ess Co Ltd: N3H-X12US {240V}
Amensolar Ess Co Ltd
12,214 W -3939 W 240.0 V 430.0 V 96.17%
Chint Power Systems America: CPS ECH12KTL/US {240V}
Chint Power Systems America
11,990 W -4163 W 240.0 V 480.0 V 96.59%
Delta Electronics: S12_BDI {240V}
Delta Electronics
11,589 W -4564 W 240.0 V 480.0 V 96.99%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Fortress Power LLC: FP-Envy Duo 21 {240V}?

Check Fortress Power LLC: FP-Envy Duo 21 {240V} (16,153 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 90 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 440 V DC on Fortress Power LLC: FP-Envy Duo 21 {240V}.

Fortress Power LLC: FP-Envy Duo 21 {240V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (67.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.61%) and MPPT window (250-440 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Fortress Power LLC: FP-Envy Duo 21 {240V} by Fortress Power LLC covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Fortress Power LLC: FP-Envy Duo 21 {240V} require?

At 16,153 W continuous AC (240 V), continuous current is 67.3 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.

Does Fortress Power LLC: FP-Envy Duo 21 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 90 A at 240 V means Needs Derate / Tap 705.11.

How does Fortress Power LLC: FP-Envy Duo 21 {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?

Fortress Power LLC: FP-Envy Duo 21 {240V} delivers 16,153 W AC at 96.61% CEC efficiency with a 440 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.