Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} outputs 427 W AC at 480Y/277 V, 3-phase (0.5 A continuous, 15 A OCPD), ranking #647 of 2,343 CEC inverters at 97.36% efficiency with a 28-45 V MPPT window and 45 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 427 W
- AC Voltage
- 480Y/277 V, 3-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 97.36%
How Does Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 480Y/277 V, 3-phase grid-support overview for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}.
Ranking #1,972 of 2,343 CEC inverters (below CEC median; higher than 15.7% of peers), Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} is a grid-tied PV inverter delivering 427 W continuous AC at 480Y/277 V, 3-phase (0.5 A continuous). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Weighted CEC efficiency reaches 97.36% (+0.54 pts vs the 96.82% 277 V median) against peers like Northern Electric & Power Co Ltd: BDM-800-277A {277V} (799 W).
Where Does Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} Fall Across Listed CEC Models?
Marks Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} (427 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}?
Benchmarks Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} continuous AC output, 97.36% CEC weighted efficiency, and 15 A OCPD breaker demand.
What Do the Dataset Ranks Show for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}?
Four key NEC 705.12 and California Energy Commission metrics defining Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} by Enphase Energy Inc.
97.36% CEC Weighted Efficiency
+0.54 pts vs the 96.82% 277 V median; overall power rank #1,972 (427 W, below CEC median; higher than 15.7% of peers).
15 A Required Backfeed OCPD
125% x 0.5 A = 0.6 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
28 V - 45 V (Max 45 V DC)
Tracking span of 17.0 V; listed since 2026-03-02 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 480Y/277 V, 3-phase switchgear (200A Bus / 200A Main (277V) to 1,200A Bus / 1,200A Main (277V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 427.0W / 480 V 3-phase -> 0.5 A | Breaker >= 1.25 * 0.5 = 0.6 A -> 15 A
CEC Inverters.csv for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}: Paco=427.0 W, Vac=277 V, Vdcmax=45.0 V, Eff=97.36%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (277V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 427 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480Y/277 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 45 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 28 V - 45 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 12.0156 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.36% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2026-03-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} (480Y/277 V, 3-phase)?
Evaluates Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (277V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (277V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (277V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (277V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (277V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}?
Sample PV string lengths aligned within 28-45 V MPPT and 45 V DC max at -10 C. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}?
Competing CEC grid-support inverters near 427 W AC and 480Y/277 V, 3-phase, led by Northern Electric & Power Co Ltd: BDM-800-277A {277V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Northern Electric & Power Co Ltd: BDM-800-277A {277V} Northern Electric & Power Co Ltd |
799 W | +372 W | 277.0 V | 55.0 V | 96.31% |
| ABB: PVI-30-OUTD-S-US-A {277V} ABB |
3,000 W | +2573 W | 277.0 V | 480.0 V | 96.56% |
| ABB: PVI-30-OUTD-S-US-Z-A {277V} ABB |
3,000 W | +2573 W | 277.0 V | 480.0 V | 96.56% |
| ABB: PVI-30-OUTD-S-US-Z-M-A {277V} ABB |
3,000 W | +2573 W | 277.0 V | 480.0 V | 96.56% |
What Are the Interconnection Limits and Best-Fit Uses for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}?
Check Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} (427 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 45 V DC on Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V}.
Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (0.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.36%) and MPPT window (28-45 V) directly against Northern Electric & Power Co Ltd: BDM-800-277A {277V} (799 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} by Enphase Energy Inc covering breaker sizing, MPPT limits, and 480Y/277 V, 3-phase interconnection.
What breaker and wire size does Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} require?
At 427 W continuous AC (480Y/277 V, 3-phase), continuous current is 0.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} require?
At 427 W AC and 480Y/277 V, 3-phase, continuous line current is 0.5 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (277V) or NEC 705.11 interconnection.
How does Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} compare to Northern Electric & Power Co Ltd: BDM-800-277A {277V}?
Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V} delivers 427 W AC at 97.36% CEC efficiency with a 45 V DC ceiling, while Northern Electric & Power Co Ltd: BDM-800-277A {277V} outputs 799 W at 480Y/277 V, 3-phase.