Delta Electronics: M80U_280 {480V} outputs 80,023 W AC at 480 V, 3-phase (96.3 A continuous, 125 A OCPD), ranking #193 of 2,343 CEC inverters at 98.29% efficiency with a 550-840 V MPPT window and 840 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 80,023 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 125 A (1 AWG Cu)
- CEC Efficiency
- 98.29%
How Does Delta Electronics: M80U_280 {480V} Compare Against Peer CEC Listings?
CEC efficiency rank (#193), 550-840 V MPPT tracking, and panel fit for Delta Electronics: M80U_280 {480V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Delta Electronics: M80U_280 {480V} from Delta Electronics outputs 96.3 A continuous AC at 480 V, 3-phase (80,023 W AC, rank #362). Paired with 1 AWG Cu conductors and a 125 A OCPD, its 98.29% CEC efficiency compares closely with CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} (80,000 W). Keep NEC 690.7 winter string Voc below 840 V DC.
Where Does Delta Electronics: M80U_280 {480V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Delta Electronics: M80U_280 {480V} at 80,023 W continuous AC output. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define Delta Electronics: M80U_280 {480V}?
Dataset percentiles comparing Delta Electronics: M80U_280 {480V} against 2,343 certified grid-support inverters nationwide. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for Delta Electronics: M80U_280 {480V}?
Engineering highlights for Delta Electronics: M80U_280 {480V} covering efficiency, 1 AWG Cu feeder, and panel compatibility. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
98.29% CEC Weighted Efficiency
+0.27 pts vs the 98.02% 480 V median; overall power rank #362 (80,023 W, top 15.5%; higher than 84.5% of peers).
125 A Required Backfeed OCPD
125% x 96.3 A = 120.4 A -> 125 A standard OCPD using 1 AWG Cu (75 C).
550 V - 840 V (Max 840 V DC)
Tracking span of 290.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 80023.0W / 480 V 3-phase -> 96.3 A | Breaker >= 1.25 * 96.3 = 120.4 A -> 125 A
CEC Inverters.csv for Delta Electronics: M80U_280 {480V}: Paco=80023.0 W, Vac=480 V, Vdcmax=840.0 V, Eff=98.29%.
Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Delta Electronics: M80U_280 {480V}?
California Energy Commission Solar Equipment List parameters for Delta Electronics: M80U_280 {480V} (grid-tied PV inverter) interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 80,023 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 840 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 550 V - 840 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 114.671 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.29% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to Delta Electronics: M80U_280 {480V} (480 V, 3-phase)?
Panelboard and switchgear backfeed allowances for Delta Electronics: M80U_280 {480V} (125 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 125 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (480V) | 80 A | 125 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (480V) | 120 A | 125 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (480V) | 160 A | 125 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 125 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Delta Electronics: M80U_280 {480V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Delta Electronics: M80U_280 {480V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 13 to 14 panels | 8.26 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 17 to 19 panels | 8.36 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 16 to 18 panels | 7.65 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 20 panels (fixed) | 4.0 kW |
Which Competing Grid-Support Inverters Compare to Delta Electronics: M80U_280 {480V}?
Four alternative CEC inverters matched to Delta Electronics: M80U_280 {480V} (80,023 W AC), led by CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} CSI Solar Co Ltd |
80,000 W | -23 W | 480.0 V | 850.0 V | 98.25% |
| Ginlong Technologies Co Ltd: Solis-80K-5G-US {480V} Ginlong Technologies Co Ltd |
80,000 W | -23 W | 480.0 V | 850.0 V | 98.25% |
| CSI Solar Co Ltd: CSI-80K-T480GL03-U {480V} CSI Solar Co Ltd |
79,446 W | -577 W | 480.0 V | 850.0 V | 98.11% |
| Ginlong Technologies Co Ltd: S5-GC80K-US {480V} Ginlong Technologies Co Ltd |
79,446 W | -577 W | 480.0 V | 850.0 V | 98.11% |
What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: M80U_280 {480V}?
Check Delta Electronics: M80U_280 {480V} (80,023 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 840 V DC on Delta Electronics: M80U_280 {480V}.
Delta Electronics: M80U_280 {480V} Panel & Wire Spec
Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (96.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.29%) and MPPT window (550-840 V) directly against CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} (80,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Delta Electronics: M80U_280 {480V} by Delta Electronics covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does Delta Electronics: M80U_280 {480V} require?
At 80,023 W continuous AC (480 V, 3-phase), continuous current is 96.3 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Delta Electronics: M80U_280 {480V} require?
At 80,023 W AC and 480 V, 3-phase, continuous line current is 96.3 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does Delta Electronics: M80U_280 {480V} compare to CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}?
Delta Electronics: M80U_280 {480V} delivers 80,023 W AC at 98.29% CEC efficiency with a 840 V DC ceiling, while CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} outputs 80,000 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)