Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Delta Electronics: M80U_122 {480V} — CEC Inverter Specifications

Manufacturer: Delta Electronics Registry: CEC Verified Engineering Specification

Delta Electronics: M80U_122 {480V} outputs 82,764 W AC at 480 V, 3-phase (99.6 A continuous, 125 A OCPD), ranking #337 of 2,343 CEC inverters at 98.02% efficiency with a 600-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
82,764 W
AC Voltage
480 V, 3-phase
Min PV Breaker
125 A (1 AWG Cu)
CEC Efficiency
98.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: M80U_122 {480V} Compare Against Peer CEC Listings?

Breaker sizing (125 A), 1 AWG Cu wire rules, and DC input limits for Delta Electronics: M80U_122 {480V}.

For NEC 705.12 solar interconnection, Delta Electronics: M80U_122 {480V} outputs 99.6 A continuous AC at 480 V, 3-phase and needs a 125 A backfeed breaker on 1 AWG Cu (75 C). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Conversion efficiency scores 98.02% (#337 of 2,343, +1.20 pts vs overall CEC median).

Where Does Delta Electronics: M80U_122 {480V} Fall Across Listed CEC Models?

Output power comparison showing where Delta Electronics: M80U_122 {480V} sits among all 2,343 CEC-listed grid-support inverters. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: M80U_122 {480V} (82,764 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 82,764 W

What Dataset Percentiles Define Delta Electronics: M80U_122 {480V}?

Relative ranking of Delta Electronics: M80U_122 {480V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Delta Electronics: M80U_122 {480V} Technical ThresholdsPercentile comparison for Delta Electronics: M80U_122 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output82,764 WCEC Efficiency98.02%Backfeed Breaker125 A

What Do the Dataset Ranks Show for Delta Electronics: M80U_122 {480V}?

Snapshot of Delta Electronics: M80U_122 {480V} efficiency rank (#337), OCPD breaker size, MPPT span, and busbar verdict.

Eff #337 / 2,343

98.02% CEC Weighted Efficiency

equal to the 98.02% 480 V median; overall power rank #358 (82,764 W, top 15.4%; higher than 84.6% of peers).

NEC 705.12 Check

125 A Required Backfeed OCPD

125% x 99.6 A = 124.5 A -> 125 A standard OCPD using 1 AWG Cu (75 C).

MPPT Window

600 V - 800 V (Max 800 V DC)

Tracking span of 200.0 V; listed since 2020-11-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 82764.0W / 480 V 3-phase -> 99.6 A | Breaker >= 1.25 * 99.6 = 124.5 A -> 125 A

CEC Inverters.csv for Delta Electronics: M80U_122 {480V}: Paco=82764.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=98.02%.

Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Delta Electronics: M80U_122 {480V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Delta Electronics: M80U_122 {480V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: M80U_122 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 82,764 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 600 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 118.92 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.02% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-11-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Delta Electronics: M80U_122 {480V} (480 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Delta Electronics: M80U_122 {480V} at 480 V, 3-phase.

Evaluates Delta Electronics: M80U_122 {480V} (125 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 125 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 125 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Delta Electronics: M80U_122 {480V}?

Minimum and maximum series solar module strings fitting Delta Electronics: M80U_122 {480V} MPPT and 800 V limits.

Sampled CEC PV modules aligned within 600.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 panels (fixed) 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 panels (fixed) 7.92 kW
Hansol Technics Co Ltd HA650-AE-NNEA0 650.0 W 61.2 V 13 panels (fixed) 8.45 kW
Hyperion Solar HY-DH132P8-480 480.0 W 49.91 V 16 panels (fixed) 7.68 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: M80U_122 {480V}?

Peer 480 V, 3-phase CEC inverters near 82,764 W AC output such as CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}
CSI Solar Co Ltd
80,000 W -2764 W 480.0 V 850.0 V 98.25%
Ginlong Technologies Co Ltd: Solis-80K-5G-US {480V}
Ginlong Technologies Co Ltd
80,000 W -2764 W 480.0 V 850.0 V 98.25%
CSI Solar Co Ltd: CSI-80K-T480GL03-U {480V}
CSI Solar Co Ltd
79,446 W -3318 W 480.0 V 850.0 V 98.11%
Ginlong Technologies Co Ltd: S5-GC80K-US {480V}
Ginlong Technologies Co Ltd
79,446 W -3318 W 480.0 V 850.0 V 98.11%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: M80U_122 {480V}?

Check Delta Electronics: M80U_122 {480V} (82,764 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Delta Electronics: M80U_122 {480V}.

Delta Electronics: M80U_122 {480V} Panel & Wire Spec

Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (99.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.02%) and MPPT window (600-800 V) directly against CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} (80,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: M80U_122 {480V} by Delta Electronics covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Delta Electronics: M80U_122 {480V} require?

At 82,764 W continuous AC (480 V, 3-phase), continuous current is 99.6 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Delta Electronics: M80U_122 {480V} require?

At 82,764 W AC and 480 V, 3-phase, continuous line current is 99.6 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Delta Electronics: M80U_122 {480V} compare to CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}?

Delta Electronics: M80U_122 {480V} delivers 82,764 W AC at 98.02% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} outputs 80,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.