Delta Electronics: M80U_120 {480V} outputs 82,764 W AC at 480 V, 3-phase (99.6 A continuous, 125 A OCPD), ranking #337 of 2,343 CEC inverters at 98.02% efficiency with a 600-800 V MPPT window and 800 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
82,764 W
AC Voltage
480 V, 3-phase
Min PV Breaker
125 A (1 AWG Cu)
CEC Efficiency
98.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: M80U_120 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Delta Electronics: M80U_120 {480V}.

Ranking #358 of 2,343 CEC inverters (top 15.4%; higher than 84.6% of peers), Delta Electronics: M80U_120 {480V} is a grid-tied PV inverter delivering 82,764 W continuous AC at 480 V, 3-phase (99.6 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.02% (equal to the 98.02% 480 V median) against peers like CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} (80,000 W).

Where Does Delta Electronics: M80U_120 {480V} Fall Across Listed CEC Models?

Marks Delta Electronics: M80U_120 {480V} (82,764 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: M80U_120 {480V} (82,764 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 82,764 W

What Dataset Percentiles Define Delta Electronics: M80U_120 {480V}?

Benchmarks Delta Electronics: M80U_120 {480V} continuous AC output, 98.02% CEC weighted efficiency, and 125 A OCPD breaker demand.

Delta Electronics: M80U_120 {480V} Technical ThresholdsPercentile comparison for Delta Electronics: M80U_120 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output82,764 WCEC Efficiency98.02%Backfeed Breaker125 A

What Do the Dataset Ranks Show for Delta Electronics: M80U_120 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Delta Electronics: M80U_120 {480V} by Delta Electronics.

Eff #337 / 2,343

98.02% CEC Weighted Efficiency

equal to the 98.02% 480 V median; overall power rank #358 (82,764 W, top 15.4%; higher than 84.6% of peers).

NEC 705.12 Check

125 A Required Backfeed OCPD

125% x 99.6 A = 124.5 A -> 125 A standard OCPD using 1 AWG Cu (75 C).

MPPT Window

600 V - 800 V (Max 800 V DC)

Tracking span of 200.0 V; listed since 2020-11-12 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 82764.0W / 480 V 3-phase -> 99.6 A | Breaker >= 1.25 * 99.6 = 124.5 A -> 125 A

CEC Inverters.csv for Delta Electronics: M80U_120 {480V}: Paco=82764.0 W, Vac=480 V, Vdcmax=800.0 V, Eff=98.02%.

Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Delta Electronics: M80U_120 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Delta Electronics: M80U_120 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: M80U_120 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 82,764 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 800 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 600 V - 800 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 118.92 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.02% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-11-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Delta Electronics: M80U_120 {480V} (480 V, 3-phase)?

Evaluates Delta Electronics: M80U_120 {480V} (125 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Delta Electronics: M80U_120 {480V} (125 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 125 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 125 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Delta Electronics: M80U_120 {480V}?

Sample PV string lengths aligned within 600-800 V MPPT and 800 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 600.0-800.0 V MPPT and 800.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 panels (fixed) 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 panels (fixed) 7.92 kW
Hansol Technics Co Ltd HA650-AE-NNEA0 650.0 W 61.2 V 13 panels (fixed) 8.45 kW
Hyperion Solar HY-DH132P8-480 480.0 W 49.91 V 16 panels (fixed) 7.68 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: M80U_120 {480V}?

Competing CEC grid-support inverters near 82,764 W AC and 480 V, 3-phase, led by CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}
CSI Solar Co Ltd
80,000 W -2764 W 480.0 V 850.0 V 98.25%
Ginlong Technologies Co Ltd: Solis-80K-5G-US {480V}
Ginlong Technologies Co Ltd
80,000 W -2764 W 480.0 V 850.0 V 98.25%
CSI Solar Co Ltd: CSI-80K-T480GL03-U {480V}
CSI Solar Co Ltd
79,446 W -3318 W 480.0 V 850.0 V 98.11%
Ginlong Technologies Co Ltd: S5-GC80K-US {480V}
Ginlong Technologies Co Ltd
79,446 W -3318 W 480.0 V 850.0 V 98.11%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: M80U_120 {480V}?

Check Delta Electronics: M80U_120 {480V} (82,764 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 800 V DC on Delta Electronics: M80U_120 {480V}.

Delta Electronics: M80U_120 {480V} Panel & Wire Spec

Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (99.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.02%) and MPPT window (600-800 V) directly against CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} (80,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: M80U_120 {480V} by Delta Electronics covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Delta Electronics: M80U_120 {480V} require?

At 82,764 W continuous AC (480 V, 3-phase), continuous current is 99.6 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Delta Electronics: M80U_120 {480V} require?

At 82,764 W AC and 480 V, 3-phase, continuous line current is 99.6 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Delta Electronics: M80U_120 {480V} compare to CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V}?

Delta Electronics: M80U_120 {480V} delivers 82,764 W AC at 98.02% CEC efficiency with a 800 V DC ceiling, while CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V} outputs 80,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.