Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Delta Electronics: M24U_122 {480V} — CEC Inverter Specifications

Manufacturer: Delta Electronics Registry: CEC Verified Engineering Specification

Delta Electronics: M24U_122 {480V} outputs 26,403 W AC at 480 V, 3-phase (31.8 A continuous, 40 A OCPD), ranking #238 of 2,343 CEC inverters at 98.21% efficiency with a 415-830 V MPPT window and 830 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
26,403 W
AC Voltage
480 V, 3-phase
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
98.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: M24U_122 {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Delta Electronics: M24U_122 {480V}.

Ranking #588 of 2,343 CEC inverters (top 25.2%; higher than 74.8% of peers), Delta Electronics: M24U_122 {480V} is a grid-tied PV inverter delivering 26,403 W continuous AC at 480 V, 3-phase (31.8 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.21% (+0.19 pts vs the 98.02% 480 V median) against peers like Canadian Solar Inc: CSI-25KTL-GS-FL {480V} (25,000 W).

Where Does Delta Electronics: M24U_122 {480V} Fall Across Listed CEC Models?

Marks Delta Electronics: M24U_122 {480V} (26,403 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: M24U_122 {480V} (26,403 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 26,403 W

What Dataset Percentiles Define Delta Electronics: M24U_122 {480V}?

Benchmarks Delta Electronics: M24U_122 {480V} continuous AC output, 98.21% CEC weighted efficiency, and 40 A OCPD breaker demand.

Delta Electronics: M24U_122 {480V} Technical ThresholdsPercentile comparison for Delta Electronics: M24U_122 {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output26,403 WCEC Efficiency98.21%Backfeed Breaker40 A

What Do the Dataset Ranks Show for Delta Electronics: M24U_122 {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Delta Electronics: M24U_122 {480V} by Delta Electronics.

Eff #238 / 2,343

98.21% CEC Weighted Efficiency

+0.19 pts vs the 98.02% 480 V median; overall power rank #588 (26,403 W, top 25.2%; higher than 74.8% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 31.8 A = 39.8 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

415 V - 830 V (Max 830 V DC)

Tracking span of 415.0 V; listed since 2020-03-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 26403.0W / 480 V 3-phase -> 31.8 A | Breaker >= 1.25 * 31.8 = 39.8 A -> 40 A

CEC Inverters.csv for Delta Electronics: M24U_122 {480V}: Paco=26403.0 W, Vac=480 V, Vdcmax=830.0 V, Eff=98.21%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Delta Electronics: M24U_122 {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Delta Electronics: M24U_122 {480V}.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: M24U_122 {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 26,403 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 830 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 415 V - 830 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 37.8664 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.21% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-03-02 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Delta Electronics: M24U_122 {480V} (480 V, 3-phase)?

Evaluates Delta Electronics: M24U_122 {480V} (40 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Delta Electronics: M24U_122 {480V} (40 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 40 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (480V) 80 A 40 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 40 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 40 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 40 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Delta Electronics: M24U_122 {480V}?

Sample PV string lengths aligned within 415-830 V MPPT and 830 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 415.0-830.0 V MPPT and 830.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 10 to 14 panels 8.26 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 13 to 19 panels 8.36 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 13 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 15 to 20 panels 4.0 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: M24U_122 {480V}?

Competing CEC grid-support inverters near 26,403 W AC and 480 V, 3-phase, led by Canadian Solar Inc: CSI-25KTL-GS-FL {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Canadian Solar Inc: CSI-25KTL-GS-FL {480V}
Canadian Solar Inc
25,000 W -1403 W 480.0 V 780.0 V 97.73%
Chint Power Systems America: CPS SCA25KTL-DO-R/US-480 {480V}
Chint Power Systems America
25,000 W -1403 W 480.0 V 850.0 V 97.85%
CSI Solar Co Ltd: CSI-25KTL-GS-FLB {480V}
CSI Solar Co Ltd
25,000 W -1403 W 480.0 V 770.0 V 97.78%
CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V}
CSI Solar Co Ltd
24,958 W -1445 W 480.0 V 800.0 V 98.35%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: M24U_122 {480V}?

Check Delta Electronics: M24U_122 {480V} (26,403 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 830 V DC on Delta Electronics: M24U_122 {480V}.

Delta Electronics: M24U_122 {480V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.21%) and MPPT window (415-830 V) directly against Canadian Solar Inc: CSI-25KTL-GS-FL {480V} (25,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: M24U_122 {480V} by Delta Electronics covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Delta Electronics: M24U_122 {480V} require?

At 26,403 W continuous AC (480 V, 3-phase), continuous current is 31.8 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Delta Electronics: M24U_122 {480V} require?

At 26,403 W AC and 480 V, 3-phase, continuous line current is 31.8 A, requiring a 40 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Delta Electronics: M24U_122 {480V} compare to Canadian Solar Inc: CSI-25KTL-GS-FL {480V}?

Delta Electronics: M24U_122 {480V} delivers 26,403 W AC at 98.21% CEC efficiency with a 830 V DC ceiling, while Canadian Solar Inc: CSI-25KTL-GS-FL {480V} outputs 25,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.