Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} — CEC Inverter Specifications

Manufacturer: CSI Solar Co Ltd Registry: CEC Verified Engineering Specification

CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} outputs 59,933 W AC at 480 V, 3-phase (72.1 A continuous, 100 A OCPD), ranking #181 of 2,343 CEC inverters at 98.31% efficiency with a 526-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
59,933 W
AC Voltage
480 V, 3-phase
Min PV Breaker
100 A (3 AWG Cu)
CEC Efficiency
98.31%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#181), 526-850 V MPPT tracking, and panel fit for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}.

Operating at 480 V, 3-phase, CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} converts DC array energy at 98.31% CEC weighted efficiency (top 8.0%; higher than 92.0% of peers) with a 850 V max DC input and 84.6674 A max input current for NEC 690.7 string safety. Compare this 59,933 W grid-tied PV inverter directly with Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V} (59,933 W). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.

Where Does CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} at 59,933 W continuous AC output. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (59,933 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACCSI Solar Co Ltd: : 59,933 W

What Dataset Percentiles Define CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}?

Dataset percentiles comparing CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} against 2,343 certified grid-support inverters nationwide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} Technical ThresholdsPercentile comparison for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output59,933 WCEC Efficiency98.31%Backfeed Breaker100 A

What Do the Dataset Ranks Show for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}?

Engineering highlights for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} covering efficiency, 3 AWG Cu feeder, and panel compatibility.

Eff #181 / 2,343

98.31% CEC Weighted Efficiency

+0.29 pts vs the 98.02% 480 V median; overall power rank #421 (59,933 W, top 18.0%; higher than 82.0% of peers).

NEC 705.12 Check

100 A Required Backfeed OCPD

125% x 72.1 A = 90.1 A -> 100 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

526 V - 850 V (Max 850 V DC)

Tracking span of 324.0 V; listed since 2021-12-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 59933.0W / 480 V 3-phase -> 72.1 A | Breaker >= 1.25 * 72.1 = 90.1 A -> 100 A

CEC Inverters.csv for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}: Paco=59933.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.31%.

Result: Min 100 A breaker & 3 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}?

California Energy Commission Solar Equipment List parameters for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 59,933 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 526 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 84.6674 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.31% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2021-12-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (100 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Evaluates CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (100 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 100 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 100 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 100 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 100 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sampled CEC PV modules aligned within 526.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 13 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 16 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 16 to 18 panels 7.65 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 19 to 20 panels 4.0 kW

Which Competing Grid-Support Inverters Compare to CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}?

Four alternative CEC inverters matched to CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (59,933 W AC), led by Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V}
Ginlong Technologies Co Ltd
59,933 W Tie (0 W) 480.0 V 850.0 V 98.31%
Ginlong Technologies Co Ltd: S6-GC60K-US {480V}
Ginlong Technologies Co Ltd
59,898 W -35 W 480.0 V 850.0 V 98.26%
ABB: TRIO-600-TL-OUTD-US-480 {480V}
ABB
60,000 W +67 W 480.0 V 800.0 V 98.18%
ABB: TRIO-TM-600-US-480 {480V}
ABB
60,000 W +67 W 480.0 V 800.0 V 98.18%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}?

Check CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} (59,933 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V}.

CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (72.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.31%) and MPPT window (526-850 V) directly against Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V} (59,933 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} by CSI Solar Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} require?

At 59,933 W continuous AC (480 V, 3-phase), continuous current is 72.1 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} require?

At 59,933 W AC and 480 V, 3-phase, continuous line current is 72.1 A, requiring a 100 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} compare to Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V}?

CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V} delivers 59,933 W AC at 98.31% CEC efficiency with a 850 V DC ceiling, while Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V} outputs 59,933 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.