Cherry Solution Co Ltd: CMI-800S-WA {240V} — CEC Inverter Specifications

Manufacturer: Cherry Solution Co Ltd Registry: CEC Verified Engineering Specification

Cherry Solution Co Ltd: CMI-800S-WA {240V} outputs 800 W AC at 240 V (3.3 A continuous, 15 A OCPD), ranking #2,281 of 2,343 CEC inverters at 94.55% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
800 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
94.55%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Cherry Solution Co Ltd: CMI-800S-WA {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,281), 35-50 V MPPT tracking, and panel fit for Cherry Solution Co Ltd: CMI-800S-WA {240V}.

Operating at 240 V, Cherry Solution Co Ltd: CMI-800S-WA {240V} converts DC array energy at 94.55% CEC weighted efficiency (below overall CEC median; higher than 2.4% of peers) with a 50 V max DC input and 20.145 A max input current for NEC 690.7 string safety. Compare this 800 W grid-tied PV inverter directly with Altenergy Power System Inc: DS3-L {240V} (780 W). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.

Where Does Cherry Solution Co Ltd: CMI-800S-WA {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Cherry Solution Co Ltd: CMI-800S-WA {240V} at 800 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Cherry Solution Co Ltd: CMI-800S-WA {240V} (800 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACCherry Solution Co: 800 W

What Dataset Percentiles Define Cherry Solution Co Ltd: CMI-800S-WA {240V}?

Dataset percentiles comparing Cherry Solution Co Ltd: CMI-800S-WA {240V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Cherry Solution Co Ltd: CMI-800S-WA {240V} Technical ThresholdsPercentile comparison for Cherry Solution Co Ltd: CMI-800S-WA {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output800 WCEC Efficiency94.55%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Cherry Solution Co Ltd: CMI-800S-WA {240V}?

Engineering highlights for Cherry Solution Co Ltd: CMI-800S-WA {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility.

Eff #2,281 / 2,343

94.55% CEC Weighted Efficiency

-2.13 pts vs the 96.68% 240 V median; overall power rank #1,869 (800 W, below CEC median; higher than 20.1% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 3.3 A = 4.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

35 V - 50 V (Max 50 V DC)

Tracking span of 15.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 800.0W / 240 V -> 3.3 A | Breaker >= 1.25 * 3.3 = 4.1 A -> 15 A

CEC Inverters.csv for Cherry Solution Co Ltd: CMI-800S-WA {240V}: Paco=800.0 W, Vac=240 V, Vdcmax=50.0 V, Eff=94.55%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Cherry Solution Co Ltd: CMI-800S-WA {240V}?

California Energy Commission Solar Equipment List parameters for Cherry Solution Co Ltd: CMI-800S-WA {240V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Cherry Solution Co Ltd: CMI-800S-WA {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 800 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 50 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 35 V - 50 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 20.145 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 94.55% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Cherry Solution Co Ltd: CMI-800S-WA {240V}?

Panelboard and switchgear backfeed allowances for Cherry Solution Co Ltd: CMI-800S-WA {240V} (15 A OCPD). Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Evaluates Cherry Solution Co Ltd: CMI-800S-WA {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Cherry Solution Co Ltd: CMI-800S-WA {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Cherry Solution Co Ltd: CMI-800S-WA {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 35.0-50.0 V MPPT and 50.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Cherry Solution Co Ltd: CMI-800S-WA {240V}?

Four alternative CEC inverters matched to Cherry Solution Co Ltd: CMI-800S-WA {240V} (800 W AC), led by Altenergy Power System Inc: DS3-L {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: DS3-L {240V}
Altenergy Power System Inc
780 W -20 W 240.0 V 43.0 V 97.14%
Anker Innovations Limited: MI80L {240V}
Anker Innovations Limited
780 W -20 W 240.0 V 43.0 V 97.14%
Aptos Solar Technology LLC: MAC-800 {240V}
Aptos Solar Technology LLC
767 W -33 W 240.0 V 48.0 V 96.47%
Aptos Solar Technology LLC: MAC-800R {240V}
Aptos Solar Technology LLC
767 W -33 W 240.0 V 48.0 V 96.47%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Cherry Solution Co Ltd: CMI-800S-WA {240V}?

Check Cherry Solution Co Ltd: CMI-800S-WA {240V} (800 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on Cherry Solution Co Ltd: CMI-800S-WA {240V}.

Cherry Solution Co Ltd: CMI-800S-WA {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (3.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (94.55%) and MPPT window (35-50 V) directly against Altenergy Power System Inc: DS3-L {240V} (780 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Cherry Solution Co Ltd: CMI-800S-WA {240V} by Cherry Solution Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Cherry Solution Co Ltd: CMI-800S-WA {240V} require?

At 800 W continuous AC (240 V), continuous current is 3.3 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Cherry Solution Co Ltd: CMI-800S-WA {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Cherry Solution Co Ltd: CMI-800S-WA {240V} compare to Altenergy Power System Inc: DS3-L {240V}?

Cherry Solution Co Ltd: CMI-800S-WA {240V} delivers 800 W AC at 94.55% CEC efficiency with a 50 V DC ceiling, while Altenergy Power System Inc: DS3-L {240V} outputs 780 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.