St. Landry Parish, Louisiana (#16 by population at 82,128 residents across 37,001 housing units) carries 52.4% pre-1980 homes, 70.1% electric heating vs. 26.4% utility gas, DOE IECC 2 weather conditions, and 23 federal disaster declarations (2015–2026) under 2020 NEC. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- Pre-1980 Housing
- 52.4% (37,001 homes)
- FEMA Declarations
- 23 Federal Disaster Declarations
- Climate & NEC
- IECC 2 / 2020 NEC
- Utilities Mapped
- 3 EIA-861 utilities
What Do Housing Age, Heating Fuel, and Weather Risks Mean for St. Landry Parish Homeowners?
Local electrical realities for 55+ homeowners in St. Landry Parish: legacy wiring, utility heat loads, and storm readiness.
St. Landry Parish, LA ranks #16 of 64 in Louisiana (82,128 residents, 37,001 housing units). At 52.4% pre-1980 construction (vs. 8.9% post-2010), many St. Landry Parish homes have 100 A–150 A split-bus or early breaker panels that trigger NEC 705.12 120% busbar limits before large solar arrays or dual EV chargers fit safely. Electricity heats 70.1% of homes (versus 26.4% utility gas), amplifying winter peak kW load on 100 A–150 A main feeders and raising the savings from heat-pump tuning and solar-battery time-of-use offsets at 12.52 c/kWh. FEMA NRI highlights elevated lightning risk (percentile/index 96.374) alongside 23 federal disaster declarations since 2015, making Type 1/2 surge protection (NEC 230.67) and generator interlocks or LFP battery backup a top safety priority. Electric distribution maps to Entergy Louisiana LLC, Cleco Power LLC, Southwest Louisiana E M C.
What Are the Key Electrical, Housing, and FEMA Risk Benchmarks for St. Landry Parish?
Snapshot of St. Landry Parish residential panel age, heating fuel load, lightning hazard exposure, and 2020 NEC code cycle.
52.4% Pre-1980 Homes (15.0% Pre-1960)
Of 37,001 dwellings, 52.4% predate 1980; inspect 1965–73 aluminum wiring or undersized 60A–100A panels before major loads.
70.1% Electric Heat vs 26.4% Gas
IECC 2 climate conditions govern heat-pump capacity and cold-weather solar string Voc margins under 2020 NEC.
NRI Relatively Moderate (Lightning 96.4)
23 federal disaster declarations (2015–2026) underscore whole-home Type 1/2 surge and backup transfer needs.
16.6% Seniors | Utility Rate ~12.52 c/kWh
Electrician pay statewide averages $29.59/hr; prioritize clear breaker directories and CO alarm clearances.
How Does St. Landry Parish Rank Nationally on Housing Age and Weather Hazards?
Benchmarking St. Landry Parish's older housing stock, electric heating load, and severe weather hazards against national percentiles. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Which Federal Census, FEMA, and DOE Metrics Define St. Landry Parish?
County-level Census housing, radon and water-table, FEMA disaster, and Louisiana utility indicators for St. Landry Parish. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Indicator | Value | Electrical & Homeowner Implication |
|---|---|---|
| Population & State Rank | 82,128 (#16 of 64) | Census County Population Estimate & statewide rank |
| Housing Units (Pre-1980 / Pre-1960) | 37,001 (52.4% / 15.0%) | Indicates prevalence of 60A/100A services, aluminum branch wire, or ungrounded circuits |
| Heating Fuel Split | 70.1% Electric / 26.4% Gas / 2.8% Propane | Determines headroom when converting gas heat or dryers to 240V electric |
| Residents Aged 65+ & Median Home | 16.6% / $142,900 | Senior safety focus & local housing value baseline |
| DOE IECC Climate Zone & NEC | 2 / 2020 NEC | Sets cold design Voc limits (NEC 690.7) and GFCI/AFCI adoption year |
| FEMA Disasters (2015–2026) & NRI | 23 / NRI Relatively Moderate (88.2) | Multi-hour blackout history & composite weather hazard rating |
| Peak Weather Hazard Scores | Wind 60.5, Winter 50.3, Lightning 96.4, Hail 56.1 | FEMA National Risk Index component ratings (0–100 scale) |
| EPA Radon Zone & Water Table | Zone 3 / 1.38 ft avg water table | Basement sub-slab depressurization fan circuit & ground-rod moisture context |
| Median Household Income | $45,637/yr | Census ACS 2023 county household income benchmark |
Which Electric Utilities Serve St. Landry Parish, LA? (3)
Local utility retail tariffs and annual IEEE SAIDI outage durations covering residential meters in St. Landry Parish. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Electric Utility | Ownership | Res. Rate (c/kWh) | SAIDI (min/yr) |
|---|---|---|---|
| Entergy Louisiana LLC | Investor Owned | 11.9 | 252.8 |
| Cleco Power LLC | Investor Owned | 14.26 | — |
| Southwest Louisiana E M C | Cooperative | 11.57 | — |
How Does St. Landry Parish Compare with Adjacent Counties?
Compare pre-1980 housing age and utility service territories across four nearby Louisiana counties. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Electrical Limitations Should St. Landry Parish Homeowners Check Before Upgrades?
Weigh pre-1980 branch wiring (52.4%), lightning outages, and 2020 NEC requirements in St. Landry Parish, LA. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
- Legacy service limit: 52.4% pre-1980 housing stock means many homes still hold 100 A or stab-style panels needing NEC 220 load verification.
- Weather exposure: FEMA lightning (96.4) and 23 federal disaster declarations require outdoor disconnect labeling (NEC 230.85) and Type 1/2 surge arresters.
- Heating conversion load: transitioning from 26.4% gas or 2.8% propane heat to cold-climate heat pumps often consumes remaining 200 A breaker space.
St. Landry Parish Pre-1980 Retrofit
Audit aluminum branch splices (1965–73), tighten neutral lugs, and verify 120% solar busbar allowance before quoting.
Backup Power in IECC 2
Size standby generators or LFP batteries around 12.52 c/kWh tariffs and 23 federal disaster declarations exposure.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Homeowner wiring vintage, NEC code edition, and local utility answers grounded in federal filings for St. Landry Parish, LA.
How common is pre-1980 residential electrical wiring in St. Landry Parish, LA?
Census ACS 2023 data shows 52.4% of St. Landry Parish's 37,001 homes were built before 1980 (with 15.0% predating 1960), making 60A–100A panel evaluations and aluminum splice checks essential before adding solar or EV chargers.
Which electric utilities operate in St. Landry Parish, Louisiana?
EIA-861 utility mapping links 3 provider(s) inside St. Landry Parish, led by Entergy Louisiana LLC. Consult published equipment installation sheets alongside St Landry Parish tables before disconnecting power.
Which National Electrical Code and climate zone govern permits in St. Landry Parish?
Louisiana enforces 2020 NEC, and St. Landry Parish lies in DOE IECC climate zone 2, shaping cold-weather solar Voc margins (NEC 690.7) and outdoor GFCI/SPD rules.
Sources
- American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Demographics & Home Values — U.S. Census Bureau, 2019-2023 5-Year Estimates (retrieved 2026-11-25)
- FEMA National Risk Index (NRI) — County Lightning, High Wind, Hurricane, Winter Weather & Wildfire Risk — Federal Emergency Management Agency (FEMA), National Risk Index County Release (retrieved 2026-11-25)
- OpenFEMA Disaster Declarations Summaries v2 (Storm, Hurricane, Ice, Wildfire Grid Perils) — Federal Emergency Management Agency (FEMA), v2 (2015-2026) (retrieved 2026-11-23)
- Building America & IECC Climate Zone County Classifications — U.S. Department of Energy (DOE) / Pacific Northwest National Laboratory (PNNL), 2021/2024 IECC Climate Zones (retrieved 2026-11-25)
- Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)