Square D Homeline (HOM) Load Centers uses a 1.00 in busbar format; status: Active / UL Listed. Native breakers: Square D HOM, HOMT (tandem), HOM-AFI, HOM-GFI, HOM-DF. Classified replacement rule: Eaton Type CL (UL Classified DIVQ for listed Homeline catalog numbers). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- Busbar Format
- 1.00 in
- Safety Tier
- Active / UL Listed
- Native Breakers
- Square D HOM, HOMT (tandem)
- Classified Swap
- Eaton Type CL (DIVQ)
What Is the Square D Homeline (HOM) Load Centers Inspection and Safety Profile?
Review UL 489 listing boundaries, busbar stab geometry, acceptable replacement hardware, and common field failure points documented for Square D Homeline (HOM) Load Centers.
Square D Homeline (HOM) serves single-phase 120/240 V residential load centers with a 1.00-inch breaker footprint distinct from Square D's proprietary 0.75-inch QO series. Although both carry Schneider Electric / Square D labeling, HOM and QO breakers cannot cross-install.
When genuine HOM breakers are temporarily out of stock, UL Category DIVQ classifies Eaton Type CL breakers for specific listed Homeline panel catalog numbers. Inspectors still reject unclassified 1-inch breakers such as Siemens QP or Eaton BR inside Homeline enclosures under NEC 110.3(B).
What Are the Homeline (HOM) Load Centers Busbar and 120% Solar Backfeed Limits?
Technical panelboard limits below establish compatible main lug sizes, maximum ambient continuous breaker loading, and NEC 705.12(B)(3)(2) solar allowance.
| Engineering Parameter | Specification | Field / Code Impact |
|---|---|---|
| Bus Stab Pitch | 1.00 in residential plug-on | Standard 1-inch residential spacing; not interchangeable with QO |
| Native Branch Families | HOM, HOMT (tandem), HOM-AFI, HOM-GFI, HOM-DF | Plug-on neutral available on modern Homeline series |
| UL Classified DIVQ Fit | Eaton Type CL (listed Homeline catalog numbers) | Verify catalog table inside Eaton CL packaging |
| Tandem CTL Restriction | Slot-notched Class CTL bus stabs only | Check panel door schematic before adding HOMT tandems |
| 200A / 200A Max Solar Backfeed | 40 A (7.68 kW AC @ 240 V) | Supports 175 A main breaker derate to reach 65 A backfeed |
| EVSE 60A Branch Fit | HOM260 / HOM260GFI (2-pole 60 A) | Requires 6 AWG Cu THHN (65 A @ 75 C) for 48 A continuous EVSE |
How Does NEC 705.12 Calculate the 120% Solar Backfeed Allowance?
Follow the single-line busbar summation diagram below to verify main breaker plus PV backfeed capacity on a 200 A load center.
Which Panel Series Compare Most Closely to Homeline (HOM) Load Centers?
Inspect peer load-center architectures across major UL-listed North American manufacturers before choosing replacement breakers or upgrading service panels.
| Panel Series | Bus Format | Tier | Classified Swap |
|---|---|---|---|
| Square D QO / QOB Load Centers | 0.75 in (3/4-inch proprietary) | Active / UL Listed | No third-party 1-inch UL DIVQ classified swap; use genuine Square D QO or QOB |
| Eaton / Cutler-Hammer Type BR (Legacy Bryant / Westinghouse / Challenger) | 1.00 in | Active / UL Listed | Eaton BR is UL Listed replacement for Bryant, Westinghouse BR, and Challenger Type C/A |
| Siemens / Murray QP / QT / MP Load Centers | 1.00 in | Active / UL Listed | Eaton Type CL (UL Classified DIVQ for listed Siemens/Murray panels) |
Which CPSC Safety Recalls Match This Panel or Breaker Family? (4)
Matched U.S. Consumer Product Safety Commission hazard filings below help installers check date codes before servicing existing panels.
- Recall #14134 (2014-03-18) — Schneider Electric Recalls Square D-Brand F and K Frame Circuit Breakers Due to Fire Hazard
- Recall #10749 (2010-08-02) — Miami Breaker Recalls Counterfeit Square D Circuit Breakers Due to Fire Hazard
- Recall #08054 (2007-10-30) — Connecticut Electric Recalls Counterfeit Square D Circuit Breakers Due To Fire Hazard
- Recall #02556 (2002-08-09) — CPSC, Square D Company Announce Recall of Circuit Breakers
What Are the Limitations of Reference Data and Who Should Not Rely on It Alone?
Published government datasets and CEC lab ratings establish baseline electrical and solar bounds, subject to field verification at your specific property.
- Tariffs change mid-year: verify your electric utility's current net-billing export tariff and transformer capacity before signing contracts.
- NEC edition lags: state and city building departments enforce varying NEC editions (2017, 2020, 2023, or 2026) with local amendments.
- Not a substitute for on-site inspection: busbar pitting, ungrounded circuits, or loose neutral lugs require in-person testing by a licensed electrician.
Grid-Outage Resilience Priority
Focus on high-SAIDI utilities (>180 min/yr) and verify 120% busbar capacity for a 60 A hybrid battery or 200 A transfer switch.
Post-25D Cash Solar Payback Focus
With 0% federal 25D in 2026, prioritize higher-tariff markets above 18 c/kWh and avoid 20%-35% loan dealer fees.
EV Charging & Circuit Safety
Hardwire 48 A chargers on 6 AWG Cu THHN (75 C) rather than 6/2 NM-B, or step down to 32 A (40 A breaker) on tight 100 A panels.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers below come directly from official California Energy Commission equipment lists, U.S. Energy Information Administration utility reports, National Electrical Code rules, IRS 2026 guidance, and state licensing boards.
Can third-party classified breakers be used in Square D Homeline (HOM) Load Centers?
Eaton Type CL (UL Classified DIVQ for listed Homeline catalog numbers). Never force QO breakers onto Homeline bus stabs; check door label for tandem CTL slots.
Can a 200 A Square D Homeline (HOM) Load Centers panel handle a 60 A EV charger and solar backfeed?
Obsolete FPE/Zinsco panels must be replaced prior to EVSE or solar additions. Active UL-listed 200 A/200 A panels allow 40 A of load-side solar backfeed under NEC 705.12(B)(3)(2), or 65 A with a 175 A main breaker derate.
What breakers are UL Listed natively inside Square D Homeline (HOM) Load Centers load centers?
Only Square D HOM, HOMT (tandem), HOM-AFI, HOM-GFI, HOM-DF breakers carry direct UL 489 OEM factory listing inside Square D Homeline (HOM) Load Centers panels with 1.00 in busbar stabs without voiding panelboard warranty or NEC 110.3(B) inspection.
Are UL Classified replacement breakers permitted in Square D Homeline (HOM) Load Centers panels?
For Square D Homeline (HOM) Load Centers enclosures using 1.00 in geometry, classified replacement guidance is Eaton Type CL (UL Classified DIVQ for listed Homeline catalog numbers); verify the exact UL Category DIVQ compatibility chart printed inside the panel door.
Does Square D Homeline (HOM) Load Centers safety status affect home insurance or solar interconnection?
Square D Homeline (HOM) Load Centers holds tier 'Active / UL Listed'. Review insurer acceptance, physical busbar pitting, and NEC 705.12 120% backfeed clearance before adding heavy solar or EVSE loads.
How do electricians inspect Square D Homeline (HOM) Load Centers busbar stabs safely?
After de-energizing where possible, a licensed electrician checks Square D Homeline (HOM) Load Centers stabs for thermal discoloration, loose spring-clip tension, double-tapped neutral bars, and calibrated NEC 110.14(D) lug torque.
When should a Square D Homeline (HOM) Load Centers panel be replaced instead of repaired?
Obsolete fire-hazard enclosures, heat-damaged aluminum/copper bus stabs, rusted weatherproof cans, or maxed-out Square D Homeline (HOM) Load Centers main lugs warrant a full 200 A service panel replacement under permit.
When is a 175 A main breaker derate practical instead of a 200 A panel replacement?
Derating a 200 A main breaker to 175 A expands NEC 705.12 solar backfeed from 40 A to 65 A—provided an NEC load calculation stays below 175 A on a UL-listed panelboard.
Sources
- UL Product iQ DIVQ Classified & Listed Circuit Breaker Compatibility Reference — UL Solutions / Panel OEM Datasheets (Square D, Eaton, Siemens, GE), 2026 OEM Cross-Reference (retrieved 2026-11-23)
- CPSC Publication 516: Repairing Aluminum Wiring — U.S. Consumer Product Safety Commission (CPSC), Pub. 516 (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
- CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)