title: "Reedsburg Utility Comm (WI) Rate & SAIDI"
url: https://epri-peac.com/utilities/wi-reedsburg-utility-comm-15804/
description: "2025 EIA-861 profile for Reedsburg Utility Comm (WI): 12.36 c/kWh rate, SAIDI Not reported in EIA-861, 19 solar systems. Source-verified US engineering data."
---

EIA-861 Grid Reliability & Net Metering

# Reedsburg Utility Comm (WI) — Grid Reliability & Solar Data

Filing: **Form EIA-861 (2025 Release)** Verified: **2026-11-26**

Reedsburg Utility Comm (EIA ID 15804, WI) serves 4,956 customers at 12.36 c/kWh (-5.72 c/kWh vs Wisconsin average) with no standalone IEEE SAIDI filing (1 county served) with 19 net-metered residential solar systems (0.38% customer adoption). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **EIA Utility ID** : 15804

- **Res. Rate** : 12.36 c/kWh

- **SAIDI (All Events)** : Not reported in EIA-861

- **Net-Metered PV** : 19 systems

Electric utility distribution substation transformers, ceramic insulators, and overhead feeder lines at dusk

## How Does Reedsburg Utility Comm Compare on Tariffs and Reliability?

EIA-861 rate delta (-5.72 c/kWh vs Wisconsin average), customer scale (4,956), and 2026 solar payback benchmarks for Reedsburg Utility Comm.

Ranked #481 of 1,989 reporting US utilities for residential rate (top 24.4%; lower than 75.6% of peers), Reedsburg Utility Comm serves 4,956 accounts in Wisconsin (Municipal). Commercial power averages 10.61 c/kWh. It did not file standalone IEEE SAIDI metrics in 2025 EIA-861 (state customer-weighted SAIDI is 264.1 min/yr), with 19 net-metered residential solar systems (0.38% customer adoption).

## Where Does Reedsburg Utility Comm Sit Across US Utility Rates?

Positions Reedsburg Utility Comm (12.36 c/kWh) across 1,989 US electric utility residential tariffs. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

## How Does Reedsburg Utility Comm Rank Across Cost & Reliability?

Percentile placement of Reedsburg Utility Comm across retail kWh electricity cost and IEEE grid reliability outage metrics. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Do EIA-861 Benchmarks Show for Reedsburg Utility Comm?

Four key EIA-861 rate, outage, and solar payback benchmarks for Reedsburg Utility Comm (Municipal) in Wisconsin. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Lowest Rate #481 / 1,989

### 12.36 c/kWh (-5.72 vs WI)

Commercial avg: 10.61 c/kWh; Industrial: 8.88 c/kWh; est. residential bill $86.78/mo.

State Reliability Context

### 264.1 min/yr (WI Avg)

Utility did not file separate IEEE SAIDI in 2025; Wisconsin customer-weighted SAIDI is 264.1 min/yr.

Post-25D Payback

### 17.7 Years @ 12.36 c/kWh

8 kW cash system ($23,600 at $2.95/W, 0% 25D) offsets ~$1,335/yr at 1,350 kWh/kW.

Distributed PV

### 19 Net-Metered Systems

0.149 MW residential PV (0.38% of customers) across 1 county; state FEMA declarations (2015-2026): 12.

Reedsburg Utility Comm Reliability & Solar Offset Calculation

Backup_Energy = (120.0 min / 60) * 1.8 kW = 3.6 kWh/event | Solar_Offset = 10,800 kWh * $0.1236 = $1,335/yr

EIA-861 2025 Utility ID 15804: Rate=12.36 c/kWh, Cust=4,956, PV=19.

**Result:** 17.7 yr 8 kW cash payback at 12.36 c/kWh (0% 25D).

## What Are the EIA-861 Filing Metrics for Reedsburg Utility Comm?

Complete Form EIA-861 filing summary for Reedsburg Utility Comm (ID 15804) covering sales, PV, and counties. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Form EIA-861 2025 filing metrics for Reedsburg Utility Comm (Utility ID 15804).

| EIA Utility ID & BA Code | ID 15804 · MISO |
|---|---|
| State & Ownership Type | WI · Municipal |
| Retail Electricity Rates | 12.36 c/kWh Res · 10.61 c Comm · 8.88 c Ind |
| Avg Monthly Usage & Bill | 702.0 kWh/mo ($86.78/mo est.) |
| Residential Net-Metered PV | 19 systems (0.149 MW) |
| Counties Served (Sample) | 1 county (Sauk) |

## Which Peer Electric Utilities Operate in WI?

Compare Reedsburg Utility Comm directly with Shawano Municipal Utilities and nearby Wisconsin electric utilities by customer base. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

In-state EIA-861 peers ranked by customer base.

| Utility | Res Rate | SAIDI | Res PV | Customers |
|---|---|---|---|---|
| [**Shawano Municipal Utilities**](https://epri-peac.com/utilities/wi-shawano-municipal-utilities-17011/) | 14.41 c | — | 0 | 4,977 |
| [**North Central Power Co Inc**](https://epri-peac.com/utilities/wi-north-central-power-co-inc-13697/) | 16.38 c | — | 50 | 5,063 |
| [**City of New Richmond**](https://epri-peac.com/utilities/wi-city-of-new-richmond-13481/) | 12.4 c | 12.9 min | 17 | 5,089 |
| [**East Central Energy**](https://epri-peac.com/utilities/wi-east-central-energy-5574/) | 17.2 c | — | 45 | 5,201 |

What to Check & Best-Fit Scenarios

## What Should Reedsburg Utility Comm Customers Check Beyond Historical EIA-861 Averages?

Form EIA-861 data for Reedsburg Utility Comm (Municipal, WI) summarizes annual utility filings—confirm active rate riders and feeder reliability at your meter.

- Annual snapshot caveat: Reedsburg Utility Comm (Municipal) reports historical 2025 EIA-861 averages rather than live rate-case riders in WI.
- Export credit rules: check Reedsburg Utility Comm's active net-billing or avoided-cost schedule before assuming 1-to-1 retail solar offset.

### Reedsburg Utility Comm Solar & Battery Evaluators

Compare your actual Reedsburg Utility Comm monthly kWh statement against 12.36 c/kWh and verify current export tariffs in WI.

### Reedsburg Utility Comm Outage & Generator Planners

Use Reedsburg Utility Comm's SAIDI history alongside NEC 705.12 120% busbar checks when sizing backup storage or transfer switches.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Reedsburg Utility Comm (Wisconsin) customers grounded in 2025 Form EIA-861 filings and NEC 705.12 rules. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

### What is Reedsburg Utility Comm's residential electricity rate and 2026 solar payback?

Reedsburg Utility Comm averages 12.36 c/kWh (-5.72 c/kWh vs Wisconsin average vs. Wisconsin). At 0% federal 25D credit in 2026, an 8 kW cash array offsets ~$1,335/yr (17.7-year payback).

### How reliable is Reedsburg Utility Comm compared to peer Wisconsin utilities?

Reedsburg Utility Comm did not file standalone IEEE SAIDI metrics in 2025 EIA-861 (state customer-weighted SAIDI is 264.1 min/yr); compare rates and outage history directly with Shawano Municipal Utilities (14.41 c/kWh) across Wisconsin.

### Which counties and customers does Reedsburg Utility Comm serve in Wisconsin?

EIA-861 filings list 4,956 customers across 1 county including Sauk, with 19 net-metered residential solar installations. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Reedsburg Utility Comm.

## Related Pages

Explore Wisconsin energy benchmarks, Shawano Municipal Utilities, county outage profiles, and NEC 705.12 tools alongside Reedsburg Utility Comm.

[Wisconsin State Energy Rates & Utilities](https://epri-peac.com/states/wisconsin/) [All Wisconsin County Power & Outage Profiles](https://epri-peac.com/counties/wisconsin/) [Check Solar 120% Busbar Rule (NEC 705.12)](https://epri-peac.com/tools/solar-busbar-120/) [All Indexed US Electric Utilities](https://epri-peac.com/utilities/)

## Sources

1. [Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory)](https://www.eia.gov/electricity/data/eia861/) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
3. [Residential Clean Energy Credit (IRC Section 25D — Terminated After Dec. 31, 2025)](https://www.irs.gov/credits-deductions/residential-clean-energy-credit) — Internal Revenue Service (IRS), 2026 Guidance (P.L. 119-21) (retrieved 2026-11-23)

Solar & Backup Calculators

Evaluate 60 A hybrid battery ESS backfeed limits (NEC 705.12) and 2026 solar payback using 12.36 c/kWh rates.
[Check 120% Busbar Rule](https://epri-peac.com/tools/solar-busbar-120/) [View Battery & Generator Specs](https://epri-peac.com/ev-chargers/)