Filing: **Form EIA-861 (2025 Release)** Verified: **2026-11-26**

Jasper-Newton Elec Coop, Inc (EIA ID 9668, TX) serves 21,316 customers at 14.1 c/kWh (-1.30 c/kWh vs Texas average) with 1,144.8 min/yr SAIDI (19.08 hrs/yr) with 113 net-metered residential solar systems (0.53% customer adoption). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **EIA Utility ID** : 9668

- **Res. Rate** : 14.1 c/kWh

- **SAIDI (All Events)** : 1,144.8 min/yr

- **Net-Metered PV** : 113 systems

Electric utility distribution substation transformers, ceramic insulators, and overhead feeder lines at dusk

## How Does Jasper-Newton Elec Coop, Inc Compare on Tariffs and Reliability?

EIA-861 rate delta (-1.30 c/kWh vs Texas average), customer scale (21,316), and 2026 solar payback benchmarks for Jasper-Newton Elec Coop, Inc.

Ranked #1,004 of 1,989 reporting US utilities for residential rate (above US utility median; lower than 49.4% of peers), Jasper-Newton Elec Coop, Inc serves 21,316 accounts in Texas (Cooperative). Commercial power averages 16.98 c/kWh. It logged 1,144.8 SAIDI outage minutes (19.08 hrs/yr, 39.1% storm-driven), making battery backup or a standby ATS worthwhile, with 113 net-metered residential solar systems (0.53% customer adoption).

## Where Does Jasper-Newton Elec Coop, Inc Sit Across US Utility Rates?

Positions Jasper-Newton Elec Coop, Inc (14.1 c/kWh) across 1,989 US electric utility residential tariffs. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## How Does Jasper-Newton Elec Coop, Inc Rank Across Cost & Reliability?

Percentile placement of Jasper-Newton Elec Coop, Inc across retail kWh electricity cost and IEEE grid reliability outage metrics.

## What Do EIA-861 Benchmarks Show for Jasper-Newton Elec Coop, Inc?

Four key EIA-861 rate, outage, and solar payback benchmarks for Jasper-Newton Elec Coop, Inc (Cooperative) in Texas. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Lowest Rate #1,004 / 1,989

### 14.1 c/kWh (-1.30 vs TX)

Commercial avg: 16.98 c/kWh; Industrial: 9.02 c/kWh; est. residential bill $156.22/mo.

Reliability #722 / 751

### 1,144.8 min/yr (19.08 hrs)

39.1% (447.5 min) from Major Event Days; avg restore 159.7 min (~4.8 kWh @ 1.8 kW).

Post-25D Payback

### 15.5 Years @ 14.1 c/kWh

8 kW cash system ($23,600 at $2.95/W, 0% 25D) offsets ~$1,523/yr at 1,350 kWh/kW.

Distributed PV

### 113 Net-Metered Systems

0.993 MW residential PV (0.53% of customers) across 5 counties; state FEMA declarations (2015-2026): 56.

Jasper-Newton Elec Coop, Inc Reliability & Solar Offset Calculation

Backup_Energy = (159.7 min / 60) * 1.8 kW = 4.8 kWh/event | Solar_Offset = 10,800 kWh * $0.1410 = $1,523/yr

EIA-861 2025 Utility ID 9668: Rate=14.1 c/kWh, Cust=21,316, SAIDI=1,144.8 min, PV=113.

**Result:** 19.08 outage hrs/yr; 15.5 yr 8 kW cash payback (0% 25D).

## What Are the EIA-861 Filing Metrics for Jasper-Newton Elec Coop, Inc?

Complete Form EIA-861 filing summary for Jasper-Newton Elec Coop, Inc (ID 9668) covering sales, PV, and counties. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Form EIA-861 2025 filing metrics for Jasper-Newton Elec Coop, Inc (Utility ID 9668).

| EIA Utility ID & BA Code | ID 9668 · MISO |
|---|---|
| State & Ownership Type | TX · Cooperative |
| Retail Electricity Rates | 14.1 c/kWh Res · 16.98 c Comm · 9.02 c Ind |
| Avg Monthly Usage & Bill | 1,107.6 kWh/mo ($156.22/mo est.) |
| SAIDI (All Events w/ MED) | 1,144.8 min/yr (19.08 hrs/yr) |
| SAIDI (Without Major Events) | 697.3 min/yr (Storm share: 39.1%) |
| SAIFI & CAIDI (Per-Outage Avg) | 7.167 /yr · 159.7 min restore |
| Residential Net-Metered PV | 113 systems (0.993 MW) |
| Counties Served (Sample) | 5 counties (Angelina, Jasper, Newton, Orange, Sabine) |

## Which Peer Electric Utilities Operate in TX?

Compare Jasper-Newton Elec Coop, Inc directly with Victoria Electric Coop, Inc and nearby Texas electric utilities by customer base.

In-state EIA-861 peers ranked by customer base.

| Utility | Res Rate | SAIDI | Res PV | Customers |
|---|---|---|---|---|
| [**Victoria Electric Coop, Inc**](https://epri-peac.com/utilities/tx-victoria-electric-coop-inc-19806/) | 12.4 c | 252.9 min | 140 | 21,716 |
| [**Houston County Elec Coop Inc**](https://epri-peac.com/utilities/tx-houston-county-elec-coop-inc-8898/) | 15.28 c | — | 0 | 21,761 |
| [**Wise Electric Coop Inc**](https://epri-peac.com/utilities/tx-wise-electric-coop-inc-20948/) | 15.33 c | — | 719 | 20,682 |
| [**Kerrville Public Utility Board**](https://epri-peac.com/utilities/tx-kerrville-public-utility-board-28604/) | 9.42 c | 85.3 min | 164 | 20,283 |

What to Check & Best-Fit Scenarios

## What Should Jasper-Newton Elec Coop, Inc Customers Check Beyond Historical EIA-861 Averages?

Form EIA-861 data for Jasper-Newton Elec Coop, Inc (Cooperative, TX) summarizes annual utility filings—confirm active rate riders and feeder reliability at your meter.

- ERCOT / retail choice note or local riders: confirm whether Jasper-Newton Elec Coop, Inc acts as a wires-only TDU or bundled utility in TX.
- Transformer limits: Jasper-Newton Elec Coop, Inc interconnection engineering still checks neighborhood transformer kVA regardless of 1,144.8 SAIDI.

### Jasper-Newton Elec Coop, Inc Solar & Battery Evaluators

Compare your actual Jasper-Newton Elec Coop, Inc monthly kWh statement against 14.1 c/kWh and verify current export tariffs in TX.

### Jasper-Newton Elec Coop, Inc Outage & Generator Planners

Use Jasper-Newton Elec Coop, Inc's SAIDI history alongside NEC 705.12 120% busbar checks when sizing backup storage or transfer switches.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Jasper-Newton Elec Coop, Inc (Texas) customers grounded in 2025 Form EIA-861 filings and NEC 705.12 rules.

### What is Jasper-Newton Elec Coop, Inc's residential electricity rate and 2026 solar payback?

Jasper-Newton Elec Coop, Inc averages 14.1 c/kWh (-1.30 c/kWh vs Texas average vs. Texas). At 0% federal 25D credit in 2026, an 8 kW cash array offsets ~$1,523/yr (15.5-year payback).

### How reliable is Jasper-Newton Elec Coop, Inc compared to peer Texas utilities?

Jasper-Newton Elec Coop, Inc logged 1,144.8 SAIDI outage minutes (19.08 hrs/yr, 39.1% storm-driven), making battery backup or a standby ATS worthwhile; compare rates and outage history directly with Victoria Electric Coop, Inc (12.4 c/kWh) across Texas.

### Which counties and customers does Jasper-Newton Elec Coop, Inc serve in Texas?

EIA-861 filings list 21,316 customers across 5 counties including Angelina, Jasper, Newton, with 113 net-metered residential solar installations. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Jasper-Newton Elec Coop, Inc.

## Related Pages

Explore Texas energy benchmarks, Victoria Electric Coop, Inc, county outage profiles, and NEC 705.12 tools alongside Jasper-Newton Elec Coop, Inc.

[Texas State Energy Rates & Utilities](https://epri-peac.com/states/texas/) [All Texas County Power & Outage Profiles](https://epri-peac.com/counties/texas/) [Check Solar 120% Busbar Rule (NEC 705.12)](https://epri-peac.com/tools/solar-busbar-120/) [All Indexed US Electric Utilities](https://epri-peac.com/utilities/)

## Sources

1. [Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory)](https://www.eia.gov/electricity/data/eia861/) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
3. [Residential Clean Energy Credit (IRC Section 25D — Terminated After Dec. 31, 2025)](https://www.irs.gov/credits-deductions/residential-clean-energy-credit) — Internal Revenue Service (IRS), 2026 Guidance (P.L. 119-21) (retrieved 2026-11-23)

Solar & Backup Calculators

Evaluate 60 A hybrid battery ESS backfeed limits (NEC 705.12) and 2026 solar payback using 14.1 c/kWh rates.
[Check 120% Busbar Rule](https://epri-peac.com/tools/solar-busbar-120/) [View Battery & Generator Specs](https://epri-peac.com/ev-chargers/)