title: "City of Lubbock - (TX) (TX) Rate & SAIDI"
url: https://epri-peac.com/utilities/tx-city-of-lubbock-tx-11292/
description: "2025 EIA-861 profile for City of Lubbock - (TX) (TX): 15.4 c/kWh rate, SAIDI 110.9 min/yr, 2025 rate & service profile. Source-verified US engineering data."
---

EIA-861 Grid Reliability & Net Metering

# City of Lubbock - (TX) (TX) — Grid Reliability & Solar Data

Filing: **Form EIA-861 (2025 Release)** Verified: **2026-11-26**

City of Lubbock - (TX) (EIA ID 11292, TX) serves 110,000 customers at TDU wires service (state avg 15.4 c/kWh) with 110.9 min/yr SAIDI (1.85 hrs/yr) with zero residential net-metered PV reported in 2025 filings. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **EIA Utility ID** : 11292

- **Res. Rate** : 15.4 c/kWh (state)

- **SAIDI (All Events)** : 110.9 min/yr

- **Net-Metered PV** : Unreported

Electric utility distribution substation transformers, ceramic insulators, and overhead feeder lines at dusk

## How Does City of Lubbock - (TX) Compare on Tariffs and Reliability?

How City of Lubbock - (TX) (Municipal) performs across 1 county on kWh rates and outage resilience. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Across 1 county including Lubbock, City of Lubbock - (TX) operates as a wires-only transmission and distribution utility (TDU) in Texas, where retail plans benchmark near 15.4 c/kWh compared to peer Tri-County Electric Coop, Inc (TX) (15.07 c/kWh). With 110,000 customer accounts (Municipal), 2025 Form EIA-861 shows City of Lubbock - (TX) recorded 110.9 SAIDI outage minutes (1.85 hrs/yr, rank #250 of 751 reporting utilities), with zero residential net-metered PV reported in 2025 filings.

## Where Does City of Lubbock - (TX) Sit Across US Utility Rates?

National utility tariff curve marking City of Lubbock - (TX) at 15.4 c/kWh vs. 18.54 c/kWh US mean.

## How Does City of Lubbock - (TX) Rank Across Cost & Reliability?

Relative ranking of City of Lubbock - (TX) on residential electricity pricing and annual IEEE SAIDI outage duration. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Do EIA-861 Benchmarks Show for City of Lubbock - (TX)?

Tariff rank, outage reliability metrics, and 2026 Post-25D solar payback figures for City of Lubbock - (TX) in Texas.

TDU Rate Context

### 15.4 c/kWh (equal to TX)

Residential tariff rank #1,297 of 1,989 (above US utility median; lower than 34.8% of peers).

Reliability #250 / 751

### 110.9 min/yr (1.85 hrs)

14.1% (15.6 min) from Major Event Days; avg restore 65.1 min (~2.0 kWh @ 1.8 kW).

Post-25D Payback

### 14.2 Years @ 15.4 c/kWh

8 kW cash system ($23,600 at $2.95/W, 0% 25D) offsets ~$1,663/yr at 1,350 kWh/kW.

Service Territory

### 110,000 Customers · 1 County

Serves 1 county including Lubbock in Texas; state FEMA declarations (2015-2026): 56.

City of Lubbock - (TX) Reliability & Solar Offset Calculation

Backup_Energy = (65.1 min / 60) * 1.8 kW = 2.0 kWh/event | Solar_Offset = 10,800 kWh * $0.1540 = $1,663/yr

EIA-861 2025 Utility ID 11292: Rate=15.4 c/kWh, Cust=110,000, SAIDI=110.9 min.

**Result:** 1.85 outage hrs/yr; 14.2 yr 8 kW cash payback (0% 25D).

## What Are the EIA-861 Filing Metrics for City of Lubbock - (TX)?

Verified customer accounts, residential and commercial tariffs, and net-metering totals filed by City of Lubbock - (TX). Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Form EIA-861 2025 filing metrics for City of Lubbock - (TX) (Utility ID 11292).

| EIA Utility ID | ID 11292 |
|---|---|
| State & Ownership Type | TX · Municipal |
| Retail Electricity Rates | TDU Wires Only (State Avg 15.4 c/kWh) |
| SAIDI (All Events w/ MED) | 110.9 min/yr (1.85 hrs/yr) |
| SAIDI (Without Major Events) | 95.3 min/yr (Storm share: 14.1%) |
| SAIFI & CAIDI (Per-Outage Avg) | 1.703 /yr · 65.1 min restore |
| Residential Net-Metered PV | Not reported in 2025 EIA-861 |
| Counties Served (Sample) | 1 county (Lubbock) |

## Which Peer Electric Utilities Operate in TX?

Nearby Texas electric utilities of comparable customer size led by Tri-County Electric Coop, Inc (TX) (15.07 c/kWh).

In-state EIA-861 peers ranked by customer base.

| Utility | Res Rate | SAIDI | Res PV | Customers |
|---|---|---|---|---|
| [**Tri-County Electric Coop, Inc (TX)**](https://epri-peac.com/utilities/tx-tri-county-electric-coop-inc-tx-19159/) | 15.07 c | 202.9 min | 1,907 | 117,857 |
| [**Bluebonnet Electric Coop, Inc**](https://epri-peac.com/utilities/tx-bluebonnet-electric-coop-inc-1892/) | 11.59 c | 113.6 min | 206 | 119,030 |
| [**Grayson-Collin Elec Coop, Inc**](https://epri-peac.com/utilities/tx-grayson-collin-elec-coop-inc-7559/) | 17.04 c | — | 3,163 | 97,950 |
| [**Guadalupe Valley Elec Coop Inc**](https://epri-peac.com/utilities/tx-guadalupe-valley-elec-coop-inc-7752/) | 11.83 c | 138.7 min | 4,517 | 95,358 |

What to Check & Best-Fit Scenarios

## What Should City of Lubbock - (TX) Customers Check Beyond Historical EIA-861 Averages?

Form EIA-861 data for City of Lubbock - (TX) (Municipal, TX) summarizes annual utility filings—confirm active rate riders and feeder reliability at your meter.

- Tariff structure differs: City of Lubbock - (TX)'s state benchmark c/kWh blended residential rate in TX does not isolate peak TOU windows or fixed customer fees.
- Feeder variation: City of Lubbock - (TX) system-wide SAIDI averages rural and urban circuits across its TX territory or nearby Tri-County Electric Coop, Inc (TX).

### City of Lubbock - (TX) Solar & Battery Evaluators

Compare your actual City of Lubbock - (TX) monthly kWh statement against state benchmark c/kWh and verify current export tariffs in TX.

### City of Lubbock - (TX) Outage & Generator Planners

Use City of Lubbock - (TX)'s SAIDI history alongside NEC 705.12 120% busbar checks when sizing backup storage or transfer switches.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for City of Lubbock - (TX) (Texas) customers grounded in 2025 Form EIA-861 filings and NEC 705.12 rules.

### What is City of Lubbock - (TX)'s residential electricity rate and 2026 solar payback?

City of Lubbock - (TX) averages 15.4 c/kWh (equal to Texas average vs. Texas). At 0% federal 25D credit in 2026, an 8 kW cash array offsets ~$1,663/yr (14.2-year payback).

### How reliable is City of Lubbock - (TX) compared to peer Texas utilities?

City of Lubbock - (TX) recorded 110.9 SAIDI outage minutes (1.85 hrs/yr, rank #250 of 751 reporting utilities); compare rates and outage history directly with Tri-County Electric Coop, Inc (TX) (15.07 c/kWh) across Texas.

### Which counties and customers does City of Lubbock - (TX) serve in Texas?

EIA-861 filings list 110,000 customers across 1 county including Lubbock, with 0 net-metered residential solar installations. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting City of Lubbock - (TX).

## Related Pages

Explore Texas energy benchmarks, Tri-County Electric Coop, Inc (TX), county outage profiles, and NEC 705.12 tools alongside City of Lubbock - (TX).

[Texas State Energy Rates & Utilities](https://epri-peac.com/states/texas/) [All Texas County Power & Outage Profiles](https://epri-peac.com/counties/texas/) [Check Solar 120% Busbar Rule (NEC 705.12)](https://epri-peac.com/tools/solar-busbar-120/) [All Indexed US Electric Utilities](https://epri-peac.com/utilities/)

## Sources

1. [Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory)](https://www.eia.gov/electricity/data/eia861/) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
3. [Residential Clean Energy Credit (IRC Section 25D — Terminated After Dec. 31, 2025)](https://www.irs.gov/credits-deductions/residential-clean-energy-credit) — Internal Revenue Service (IRS), 2026 Guidance (P.L. 119-21) (retrieved 2026-11-23)

Solar & Backup Calculators

Evaluate 60 A hybrid battery ESS backfeed limits (NEC 705.12) and 2026 solar payback using local c/kWh rates.
[Check 120% Busbar Rule](https://epri-peac.com/tools/solar-busbar-120/) [View Battery & Generator Specs](https://epri-peac.com/ev-chargers/)