title: "Delta Electric Power Assn (MS) Rate & SAIDI"
url: https://epri-peac.com/utilities/ms-delta-electric-power-assn-22815/
description: "2025 EIA-861 profile for Delta Electric Power Assn (MS): 12.7 c/kWh rate, SAIDI 1,941.0 min/yr, 4 solar systems. Verified US government and CEC engineering data."
---

EIA-861 Grid Reliability & Net Metering

# Delta Electric Power Assn (MS) — Grid Reliability & Solar Data

Filing: **Form EIA-861 (2025 Release)** Verified: **2026-11-26**

Delta Electric Power Assn (EIA ID 22815, MS) serves 21,089 customers at 12.7 c/kWh (-1.33 c/kWh vs Mississippi average) with 1,941.0 min/yr SAIDI (32.35 hrs/yr) with 4 net-metered residential solar systems (0.02% customer adoption). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **EIA Utility ID** : 22815

- **Res. Rate** : 12.7 c/kWh

- **SAIDI (All Events)** : 1,941.0 min/yr

- **Net-Metered PV** : 4 systems

Electric utility distribution substation transformers, ceramic insulators, and overhead feeder lines at dusk

## How Does Delta Electric Power Assn Compare on Tariffs and Reliability?

EIA-861 rate delta (-1.33 c/kWh vs Mississippi average), customer scale (21,089), and 2026 solar payback benchmarks for Delta Electric Power Assn.

Serving 21,089 customers across 13 counties including Attala, Bolivar, Carroll in Mississippi, Delta Electric Power Assn (Cooperative, Balancing Authority MISO) offers a low 12.7 c/kWh residential rate (-5.84 c/kWh vs US weighted mean), extending 8 kW cash solar payback to 17.2 years without federal 25D. Grid filings show the utility logged 1,941.0 SAIDI outage minutes (32.35 hrs/yr, 70.2% storm-driven), making battery backup or a standby ATS worthwhile, with 4 net-metered residential solar systems (0.02% customer adoption).

## Where Does Delta Electric Power Assn Sit Across US Utility Rates?

Positions Delta Electric Power Assn (12.7 c/kWh) across 1,989 US electric utility residential tariffs. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

## How Does Delta Electric Power Assn Rank Across Cost & Reliability?

Percentile placement of Delta Electric Power Assn across retail kWh electricity cost and IEEE grid reliability outage metrics.

## What Do EIA-861 Benchmarks Show for Delta Electric Power Assn?

Four key EIA-861 rate, outage, and solar payback benchmarks for Delta Electric Power Assn (Cooperative) in Mississippi. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Lowest Rate #562 / 1,989

### 12.7 c/kWh (-1.33 vs MS)

Commercial avg: 26.26 c/kWh; Industrial: 11.31 c/kWh; est. residential bill $129.54/mo.

Reliability #740 / 751

### 1,941.0 min/yr (32.35 hrs)

70.2% (1,363.5 min) from Major Event Days; avg restore 334.1 min (~10.0 kWh @ 1.8 kW).

Post-25D Payback

### 17.2 Years @ 12.7 c/kWh

8 kW cash system ($23,600 at $2.95/W, 0% 25D) offsets ~$1,372/yr at 1,350 kWh/kW.

Distributed PV

### 4 Net-Metered Systems

0.028 MW residential PV (0.02% of customers) across 13 counties; state FEMA declarations (2015-2026): 34.

Delta Electric Power Assn Reliability & Solar Offset Calculation

Backup_Energy = (334.1 min / 60) * 1.8 kW = 10.0 kWh/event | Solar_Offset = 10,800 kWh * $0.1270 = $1,372/yr

EIA-861 2025 Utility ID 22815: Rate=12.7 c/kWh, Cust=21,089, SAIDI=1,941.0 min, PV=4.

**Result:** 32.35 outage hrs/yr; 17.2 yr 8 kW cash payback (0% 25D).

## What Are the EIA-861 Filing Metrics for Delta Electric Power Assn?

Complete Form EIA-861 filing summary for Delta Electric Power Assn (ID 22815) covering sales, PV, and counties. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Form EIA-861 2025 filing metrics for Delta Electric Power Assn (Utility ID 22815).

| EIA Utility ID & BA Code | ID 22815 · MISO |
|---|---|
| State & Ownership Type | MS · Cooperative |
| Retail Electricity Rates | 12.7 c/kWh Res · 26.26 c Comm · 11.31 c Ind |
| Avg Monthly Usage & Bill | 1,020.1 kWh/mo ($129.54/mo est.) |
| SAIDI (All Events w/ MED) | 1,941.0 min/yr (32.35 hrs/yr) |
| SAIDI (Without Major Events) | 577.5 min/yr (Storm share: 70.2%) |
| SAIFI & CAIDI (Per-Outage Avg) | 5.81 /yr · 334.1 min restore |
| Residential Net-Metered PV | 4 systems (0.028 MW) |
| Counties Served (Sample) | 13 counties (Attala, Bolivar, Carroll, Choctaw, Grenada, Holmes, Humphreys, Leflore, Montgomery, Sunflower) |

## Which Peer Electric Utilities Operate in MS?

Compare Delta Electric Power Assn directly with Tallahatchie Valley E P A and nearby Mississippi electric utilities by customer base.

In-state EIA-861 peers ranked by customer base.

| Utility | Res Rate | SAIDI | Res PV | Customers |
|---|---|---|---|---|
| [**Tallahatchie Valley E P A**](https://epri-peac.com/utilities/ms-tallahatchie-valley-e-p-a-18447/) | 12.95 c | — | 0 | 21,509 |
| [**Southwest Mississippi E P A**](https://epri-peac.com/utilities/ms-southwest-mississippi-e-p-a-17683/) | 15.34 c | 2,736.1 min | 0 | 23,095 |
| [**Pontotoc Electric Power Assn**](https://epri-peac.com/utilities/ms-pontotoc-electric-power-assn-15211/) | 13.77 c | — | 0 | 16,453 |
| [**North East Mississippi EPA**](https://epri-peac.com/utilities/ms-north-east-mississippi-epa-40302/) | 14.19 c | — | 0 | 26,836 |

What to Check & Best-Fit Scenarios

## What Should Delta Electric Power Assn Customers Check Beyond Historical EIA-861 Averages?

Form EIA-861 data for Delta Electric Power Assn (Cooperative, MS) summarizes annual utility filings—confirm active rate riders and feeder reliability at your meter.

- Not a substitute for meter bills: tiered and seasonal kWh blocks inside Delta Electric Power Assn (MS) shift real bills away from 12.7 c/kWh.
- Outage clustering: Major Event Days skew Delta Electric Power Assn annual minutes differently than routine non-storm reliability.

### Delta Electric Power Assn Solar & Battery Evaluators

Compare your actual Delta Electric Power Assn monthly kWh statement against 12.7 c/kWh and verify current export tariffs in MS.

### Delta Electric Power Assn Outage & Generator Planners

Use Delta Electric Power Assn's SAIDI history alongside NEC 705.12 120% busbar checks when sizing backup storage or transfer switches.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electric Power Assn (Mississippi) customers grounded in 2025 Form EIA-861 filings and NEC 705.12 rules.

### What is Delta Electric Power Assn's residential electricity rate and 2026 solar payback?

Delta Electric Power Assn averages 12.7 c/kWh (-1.33 c/kWh vs Mississippi average vs. Mississippi). At 0% federal 25D credit in 2026, an 8 kW cash array offsets ~$1,372/yr (17.2-year payback).

### How reliable is Delta Electric Power Assn compared to peer Mississippi utilities?

Delta Electric Power Assn logged 1,941.0 SAIDI outage minutes (32.35 hrs/yr, 70.2% storm-driven), making battery backup or a standby ATS worthwhile; compare rates and outage history directly with Tallahatchie Valley E P A (12.95 c/kWh) across Mississippi.

### Which counties and customers does Delta Electric Power Assn serve in Mississippi?

EIA-861 filings list 21,089 customers across 13 counties including Attala, Bolivar, Carroll, with 4 net-metered residential solar installations. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Delta Electric Power Assn.

## Related Pages

Explore Mississippi energy benchmarks, Tallahatchie Valley E P A, county outage profiles, and NEC 705.12 tools alongside Delta Electric Power Assn.

[Mississippi State Energy Rates & Utilities](https://epri-peac.com/states/mississippi/) [All Mississippi County Power & Outage Profiles](https://epri-peac.com/counties/mississippi/) [Check Solar 120% Busbar Rule (NEC 705.12)](https://epri-peac.com/tools/solar-busbar-120/) [All Indexed US Electric Utilities](https://epri-peac.com/utilities/)

## Sources

1. [Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory)](https://www.eia.gov/electricity/data/eia861/) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
3. [Residential Clean Energy Credit (IRC Section 25D — Terminated After Dec. 31, 2025)](https://www.irs.gov/credits-deductions/residential-clean-energy-credit) — Internal Revenue Service (IRS), 2026 Guidance (P.L. 119-21) (retrieved 2026-11-23)

Solar & Backup Calculators

Evaluate 60 A hybrid battery ESS backfeed limits (NEC 705.12) and 2026 solar payback using 12.7 c/kWh rates.
[Check 120% Busbar Rule](https://epri-peac.com/tools/solar-busbar-120/) [View Battery & Generator Specs](https://epri-peac.com/ev-chargers/)