title: "City of Alexandria - (MN) (MN) Rate & SAIDI"
url: https://epri-peac.com/utilities/mn-city-of-alexandria-mn-295/
description: "2025 EIA-861 profile for City of Alexandria - (MN) (MN): 11.99 c/kWh rate, SAIDI 15.5 min/yr, 18 solar systems. Verified US government and CEC engineering data."
---

EIA-861 Grid Reliability & Net Metering

# City of Alexandria - (MN) (MN) — Grid Reliability & Solar Data

Filing: **Form EIA-861 (2025 Release)** Verified: **2026-11-26**

City of Alexandria - (MN) (EIA ID 295, MN) serves 8,871 customers at 11.99 c/kWh (-3.84 c/kWh vs Minnesota average) with 15.5 min/yr SAIDI (0.26 hrs/yr) with 18 net-metered residential solar systems (0.2% customer adoption). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **EIA Utility ID** : 295

- **Res. Rate** : 11.99 c/kWh

- **SAIDI (All Events)** : 15.5 min/yr

- **Net-Metered PV** : 18 systems

Electric utility distribution substation transformers, ceramic insulators, and overhead feeder lines at dusk

## How Does City of Alexandria - (MN) Compare on Tariffs and Reliability?

EIA-861 rate delta (-3.84 c/kWh vs Minnesota average), customer scale (8,871), and 2026 solar payback benchmarks for City of Alexandria - (MN).

Serving 8,871 customers across 1 county including Douglas in Minnesota, City of Alexandria - (MN) (Municipal, Balancing Authority MISO) offers a low 11.99 c/kWh residential rate (-6.55 c/kWh vs US weighted mean), extending 8 kW cash solar payback to 18.2 years without federal 25D. Grid filings show the utility recorded 15.5 SAIDI outage minutes (0.26 hrs/yr, rank #26 of 751 reporting utilities), with 18 net-metered residential solar systems (0.2% customer adoption).

## Where Does City of Alexandria - (MN) Sit Across US Utility Rates?

Positions City of Alexandria - (MN) (11.99 c/kWh) across 1,989 US electric utility residential tariffs. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## How Does City of Alexandria - (MN) Rank Across Cost & Reliability?

Percentile placement of City of Alexandria - (MN) across retail kWh electricity cost and IEEE grid reliability outage metrics.

## What Do EIA-861 Benchmarks Show for City of Alexandria - (MN)?

Four key EIA-861 rate, outage, and solar payback benchmarks for City of Alexandria - (MN) (Municipal) in Minnesota. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Lowest Rate #399 / 1,989

### 11.99 c/kWh (-3.84 vs MN)

Commercial avg: 12.53 c/kWh; Industrial: 9.45 c/kWh; est. residential bill $91.04/mo.

Reliability #26 / 751

### 15.5 min/yr (0.26 hrs)

40.0% (6.2 min) from Major Event Days; avg restore 57.4 min (~1.7 kWh @ 1.8 kW).

Post-25D Payback

### 18.2 Years @ 11.99 c/kWh

8 kW cash system ($23,600 at $2.95/W, 0% 25D) offsets ~$1,295/yr at 1,350 kWh/kW.

Distributed PV

### 18 Net-Metered Systems

0.168 MW residential PV (0.2% of customers) across 1 county; state FEMA declarations (2015-2026): 15.

City of Alexandria - (MN) Reliability & Solar Offset Calculation

Backup_Energy = (57.4 min / 60) * 1.8 kW = 1.7 kWh/event | Solar_Offset = 10,800 kWh * $0.1199 = $1,295/yr

EIA-861 2025 Utility ID 295: Rate=11.99 c/kWh, Cust=8,871, SAIDI=15.5 min, PV=18.

**Result:** 0.26 outage hrs/yr; 18.2 yr 8 kW cash payback (0% 25D).

## What Are the EIA-861 Filing Metrics for City of Alexandria - (MN)?

Complete Form EIA-861 filing summary for City of Alexandria - (MN) (ID 295) covering sales, PV, and counties. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Form EIA-861 2025 filing metrics for City of Alexandria - (MN) (Utility ID 295).

| EIA Utility ID & BA Code | ID 295 · MISO |
|---|---|
| State & Ownership Type | MN · Municipal |
| Retail Electricity Rates | 11.99 c/kWh Res · 12.53 c Comm · 9.45 c Ind |
| Avg Monthly Usage & Bill | 759.0 kWh/mo ($91.04/mo est.) |
| SAIDI (All Events w/ MED) | 15.5 min/yr (0.26 hrs/yr) |
| SAIDI (Without Major Events) | 9.3 min/yr (Storm share: 40.0%) |
| SAIFI & CAIDI (Per-Outage Avg) | 0.27 /yr · 57.4 min restore |
| Residential Net-Metered PV | 18 systems (0.168 MW) |
| Counties Served (Sample) | 1 county (Douglas) |

## Which Peer Electric Utilities Operate in MN?

Compare City of Alexandria - (MN) directly with Meeker Coop Light & Power Assn and nearby Minnesota electric utilities by customer base.

In-state EIA-861 peers ranked by customer base.

| Utility | Res Rate | SAIDI | Res PV | Customers |
|---|---|---|---|---|
| [**Meeker Coop Light & Power Assn**](https://epri-peac.com/utilities/mn-meeker-coop-light-power-assn-12227/) | 14.03 c | 151.2 min | 89 | 8,593 |
| [**Willmar Municipal Utilities (MN)**](https://epri-peac.com/utilities/mn-willmar-municipal-utilities-mn-20737/) | 13.77 c | 16.1 min | 13 | 8,521 |
| [**Brainerd Public Utilities**](https://epri-peac.com/utilities/mn-brainerd-public-utilities-2138/) | 12.1 c | 21.3 min | 0 | 7,014 |
| [**Steele-Waseca Cooperative Electric**](https://epri-peac.com/utilities/mn-steele-waseca-cooperative-electric-18047/) | 16.46 c | 90.2 min | 225 | 10,788 |

What to Check & Best-Fit Scenarios

## What Should City of Alexandria - (MN) Customers Check Beyond Historical EIA-861 Averages?

Form EIA-861 data for City of Alexandria - (MN) (Municipal, MN) summarizes annual utility filings—confirm active rate riders and feeder reliability at your meter.

- Not a substitute for meter bills: tiered and seasonal kWh blocks inside City of Alexandria - (MN) (MN) shift real bills away from 11.99 c/kWh.
- Outage clustering: Major Event Days skew City of Alexandria - (MN) annual minutes differently than routine non-storm reliability.

### City of Alexandria - (MN) Solar & Battery Evaluators

Compare your actual City of Alexandria - (MN) monthly kWh statement against 11.99 c/kWh and verify current export tariffs in MN.

### City of Alexandria - (MN) Outage & Generator Planners

Use City of Alexandria - (MN)'s SAIDI history alongside NEC 705.12 120% busbar checks when sizing backup storage or transfer switches.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for City of Alexandria - (MN) (Minnesota) customers grounded in 2025 Form EIA-861 filings and NEC 705.12 rules.

### What is City of Alexandria - (MN)'s residential electricity rate and 2026 solar payback?

City of Alexandria - (MN) averages 11.99 c/kWh (-3.84 c/kWh vs Minnesota average vs. Minnesota). At 0% federal 25D credit in 2026, an 8 kW cash array offsets ~$1,295/yr (18.2-year payback).

### How reliable is City of Alexandria - (MN) compared to peer Minnesota utilities?

City of Alexandria - (MN) recorded 15.5 SAIDI outage minutes (0.26 hrs/yr, rank #26 of 751 reporting utilities); compare rates and outage history directly with Meeker Coop Light & Power Assn (14.03 c/kWh) across Minnesota.

### Which counties and customers does City of Alexandria - (MN) serve in Minnesota?

EIA-861 filings list 8,871 customers across 1 county including Douglas, with 18 net-metered residential solar installations. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting City of Alexandria - (MN).

## Related Pages

Explore Minnesota energy benchmarks, Meeker Coop Light & Power Assn, county outage profiles, and NEC 705.12 tools alongside City of Alexandria - (MN).

[Minnesota State Energy Rates & Utilities](https://epri-peac.com/states/minnesota/) [All Minnesota County Power & Outage Profiles](https://epri-peac.com/counties/minnesota/) [Check Solar 120% Busbar Rule (NEC 705.12)](https://epri-peac.com/tools/solar-busbar-120/) [All Indexed US Electric Utilities](https://epri-peac.com/utilities/)

## Sources

1. [Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory)](https://www.eia.gov/electricity/data/eia861/) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
3. [Residential Clean Energy Credit (IRC Section 25D — Terminated After Dec. 31, 2025)](https://www.irs.gov/credits-deductions/residential-clean-energy-credit) — Internal Revenue Service (IRS), 2026 Guidance (P.L. 119-21) (retrieved 2026-11-23)

Solar & Backup Calculators

Evaluate 60 A hybrid battery ESS backfeed limits (NEC 705.12) and 2026 solar payback using 11.99 c/kWh rates.
[Check 120% Busbar Rule](https://epri-peac.com/tools/solar-busbar-120/) [View Battery & Generator Specs](https://epri-peac.com/ev-chargers/)