title: "Y-W Electric Assn Inc (CO) Rate & SAIDI"
url: https://epri-peac.com/utilities/co-y-w-electric-assn-inc-21075/
description: "2025 EIA-861 profile for Y-W Electric Assn Inc (CO): 15.66 c/kWh rate, SAIDI 699.7 min/yr, 35 solar systems. Verified US government and CEC engineering data."
---

EIA-861 Grid Reliability & Net Metering

# Y-W Electric Assn Inc (CO) — Grid Reliability & Solar Data

Filing: **Form EIA-861 (2025 Release)** Verified: **2026-11-26**

Y-W Electric Assn Inc (EIA ID 21075, CO) serves 4,878 customers at 15.66 c/kWh (-0.03 c/kWh vs Colorado average) with 699.7 min/yr SAIDI (11.66 hrs/yr) with 35 net-metered residential solar systems (0.72% customer adoption). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

- **EIA Utility ID** : 21075

- **Res. Rate** : 15.66 c/kWh

- **SAIDI (All Events)** : 699.7 min/yr

- **Net-Metered PV** : 35 systems

Electric utility distribution substation transformers, ceramic insulators, and overhead feeder lines at dusk

## How Does Y-W Electric Assn Inc Compare on Tariffs and Reliability?

How Y-W Electric Assn Inc (Cooperative) performs across 2 counties on kWh rates and outage resilience. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Y-W Electric Assn Inc (Cooperative) logged 699.7 SAIDI outage minutes (11.66 hrs/yr, 0.0% storm-driven), making battery backup or a standby ATS worthwhile. Typical residential meters drew 777.4 kWh/mo ($121.70/mo) in 2025, while its tariff bills residential power at 15.66 c/kWh (-0.03 c/kWh vs Colorado average vs. Colorado), offsetting ~$1,691/yr on an 8 kW array—compare rates directly with Highline Electric Assn (15.16 c/kWh).

## Where Does Y-W Electric Assn Inc Sit Across US Utility Rates?

National utility tariff curve marking Y-W Electric Assn Inc at 15.66 c/kWh vs. 18.54 c/kWh US mean.

## How Does Y-W Electric Assn Inc Rank Across Cost & Reliability?

Relative ranking of Y-W Electric Assn Inc on residential electricity pricing and annual IEEE SAIDI outage duration. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

## What Do EIA-861 Benchmarks Show for Y-W Electric Assn Inc?

Tariff rank, outage reliability metrics, and 2026 Post-25D solar payback figures for Y-W Electric Assn Inc in Colorado.

Lowest Rate #1,355 / 1,989

### 15.66 c/kWh (-0.03 vs CO)

Commercial avg: 10.13 c/kWh; Industrial: 13.89 c/kWh; est. residential bill $121.70/mo.

Reliability #676 / 751

### 699.7 min/yr (11.66 hrs)

0.0% (0.0 min) from Major Event Days.

Post-25D Payback

### 14.0 Years @ 15.66 c/kWh

8 kW cash system ($23,600 at $2.95/W, 0% 25D) offsets ~$1,691/yr at 1,350 kWh/kW.

Distributed PV

### 35 Net-Metered Systems

0.279 MW residential PV (0.72% of customers) across 2 counties; state FEMA declarations (2015-2026): 28.

Y-W Electric Assn Inc Reliability & Solar Offset Calculation

Backup_Energy = (120.0 min / 60) * 1.8 kW = 3.6 kWh/event | Solar_Offset = 10,800 kWh * $0.1566 = $1,691/yr

EIA-861 2025 Utility ID 21075: Rate=15.66 c/kWh, Cust=4,878, SAIDI=699.7 min, PV=35.

**Result:** 11.66 outage hrs/yr; 14.0 yr 8 kW cash payback (0% 25D).

## What Are the EIA-861 Filing Metrics for Y-W Electric Assn Inc?

Verified customer accounts, residential and commercial tariffs, and net-metering totals filed by Y-W Electric Assn Inc. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Form EIA-861 2025 filing metrics for Y-W Electric Assn Inc (Utility ID 21075).

| EIA Utility ID & BA Code | ID 21075 · WACM |
|---|---|
| State & Ownership Type | CO · Cooperative |
| Retail Electricity Rates | 15.66 c/kWh Res · 10.13 c Comm · 13.89 c Ind |
| Avg Monthly Usage & Bill | 777.4 kWh/mo ($121.70/mo est.) |
| SAIDI (All Events w/ MED) | 699.7 min/yr (11.66 hrs/yr) |
| SAIDI (Without Major Events) | 699.7 min/yr (Storm share: 0.0%) |
| Residential Net-Metered PV | 35 systems (0.279 MW) |
| Counties Served (Sample) | 2 counties (Washington, Yuma) |

## Which Peer Electric Utilities Operate in CO?

Nearby Colorado electric utilities of comparable customer size led by Highline Electric Assn (15.16 c/kWh). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

In-state EIA-861 peers ranked by customer base.

| Utility | Res Rate | SAIDI | Res PV | Customers |
|---|---|---|---|---|
| [**Highline Electric Assn**](https://epri-peac.com/utilities/co-highline-electric-assn-8570/) | 15.16 c | — | 63 | 5,013 |
| [**City of Fort Morgan**](https://epri-peac.com/utilities/co-city-of-fort-morgan-6610/) | 7.31 c | — | 31 | 5,434 |
| [**Morgan County Rural Elec Assn**](https://epri-peac.com/utilities/co-morgan-county-rural-elec-assn-12860/) | 14.46 c | — | 92 | 5,891 |
| [**K C Electric Association**](https://epri-peac.com/utilities/co-k-c-electric-association-10066/) | 13.02 c | — | 22 | 3,411 |

What to Check & Best-Fit Scenarios

## What Should Y-W Electric Assn Inc Customers Check Beyond Historical EIA-861 Averages?

Form EIA-861 data for Y-W Electric Assn Inc (Cooperative, CO) summarizes annual utility filings—confirm active rate riders and feeder reliability at your meter.

- Annual snapshot caveat: Y-W Electric Assn Inc (Cooperative) reports historical 2025 EIA-861 averages rather than live rate-case riders in CO.
- Export credit rules: check Y-W Electric Assn Inc's active net-billing or avoided-cost schedule before assuming 1-to-1 retail solar offset.

### Y-W Electric Assn Inc Solar & Battery Evaluators

Compare your actual Y-W Electric Assn Inc monthly kWh statement against 15.66 c/kWh and verify current export tariffs in CO.

### Y-W Electric Assn Inc Outage & Generator Planners

Use Y-W Electric Assn Inc's SAIDI history alongside NEC 705.12 120% busbar checks when sizing backup storage or transfer switches.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Y-W Electric Assn Inc (Colorado) customers grounded in 2025 Form EIA-861 filings and NEC 705.12 rules.

### What is Y-W Electric Assn Inc's residential electricity rate and 2026 solar payback?

Y-W Electric Assn Inc averages 15.66 c/kWh (-0.03 c/kWh vs Colorado average vs. Colorado). At 0% federal 25D credit in 2026, an 8 kW cash array offsets ~$1,691/yr (14.0-year payback).

### How reliable is Y-W Electric Assn Inc compared to peer Colorado utilities?

Y-W Electric Assn Inc logged 699.7 SAIDI outage minutes (11.66 hrs/yr, 0.0% storm-driven), making battery backup or a standby ATS worthwhile; compare rates and outage history directly with Highline Electric Assn (15.16 c/kWh) across Colorado.

### Which counties and customers does Y-W Electric Assn Inc serve in Colorado?

EIA-861 filings list 4,878 customers across 2 counties including Washington, Yuma, with 35 net-metered residential solar installations. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Y-W Electric Assn Inc.

## Related Pages

Explore Colorado energy benchmarks, Highline Electric Assn, county outage profiles, and NEC 705.12 tools alongside Y-W Electric Assn Inc.

[Colorado State Energy Rates & Utilities](https://epri-peac.com/states/colorado/) [All Colorado County Power & Outage Profiles](https://epri-peac.com/counties/colorado/) [Check Solar 120% Busbar Rule (NEC 705.12)](https://epri-peac.com/tools/solar-busbar-120/) [All Indexed US Electric Utilities](https://epri-peac.com/utilities/)

## Sources

1. [Annual Electric Power Industry Report, Form EIA-861 (Reliability, Sales, Net Metering, Average Bill, Service Territory)](https://www.eia.gov/electricity/data/eia861/) — U.S. Energy Information Administration (EIA), 2025 Release (f8612025) (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
3. [Residential Clean Energy Credit (IRC Section 25D — Terminated After Dec. 31, 2025)](https://www.irs.gov/credits-deductions/residential-clean-energy-credit) — Internal Revenue Service (IRS), 2026 Guidance (P.L. 119-21) (retrieved 2026-11-23)

Solar & Backup Calculators

Evaluate 60 A hybrid battery ESS backfeed limits (NEC 705.12) and 2026 solar payback using 15.66 c/kWh rates.
[Check 120% Busbar Rule](https://epri-peac.com/tools/solar-busbar-120/) [View Battery & Generator Specs](https://epri-peac.com/ev-chargers/)