title: "Zebra Energy ZBR-255M Specs (255.0W, 38.19V Voc)"
url: https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-255m/
description: "CEC datasheet for Zebra Energy ZBR-255M: 255.0W STC, 38.19V Voc, 32-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Zebra Energy ZBR-255M — CEC Solar Module Specifications

Manufacturer: [**Zebra Energy**](https://epri-peac.com/solar-equipment/brands/zebra-energy/) Registry: **CEC Verified Engineering Specification**

Zebra Energy ZBR-255M is a 255.0 W STC (230.6 W PTC) Mono-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.61% efficiency, 38.19 V Voc at 25 C, and 43.74 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 255.0 W

- **PTC Wattage** : 230.6 W

- **Voc @ 25C** : 38.19 V

- **Efficiency** : 15.61%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Zebra Energy ZBR-255M Compare Against Peer CEC Listings?

Engineering position of Zebra Energy ZBR-255M (255.0 W STC) vs. Changzhou Nesl Solartech DJ-255D/C-ST15 across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Zebra Energy ZBR-255M pairs typical 90.4% PTC-to-STC thermal output (230.6 W real-world rating) with 38.19 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,379 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Changzhou Nesl Solartech DJ-255D/C-ST15 offers a 255.0 W alternative.

## Where Does Zebra Energy ZBR-255M Fall Across Listed CEC Models?

Plots Zebra Energy ZBR-255M at 255.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Zebra Energy ZBR-255M?

Benchmarks Zebra Energy ZBR-255M on STC wattage, thermal PTC/STC retention, and 15.61 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Zebra Energy ZBR-255M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Zebra Energy ZBR-255M by Zebra Energy.

Rank #19,421 / 21,677

### 255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,785

### 15.61% Aperture Efficiency

Power density 156.2 W/m2 (4.30 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.74 V at -10 C (568.6 V string) and 45.32 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,160 W STC

Occupies 52.3 m2 (562 sq ft) producing 7,379 W PTC; NEC 690.8 OCPD floor is 13.95 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.19 * (1 + (-0.415/100) * (-10 - 25)) = 43.74 V | OCPD = 1.56 * 8.94 = 13.95 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-255M: Voc=38.19 V, beta_Voc=-0.415%/C, Isc=8.94 A, STC=255.0 W, Area=1.633 m2.

**Result:** 13 panels max on 600 V (568.6 V); 32 panels for 8 kW (562 sq ft).

## What Are the Published CEC Specifications for Zebra Energy ZBR-255M?

Laboratory test ratings recorded for Zebra Energy ZBR-255M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-255M.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 230.6 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.19 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.8 V / 8.28 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.415 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.61% (1.633 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Zebra Energy ZBR-255M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (562 sq ft at 8 kW), and estimated Year-1 electric bill offset for Zebra Energy ZBR-255M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.12 kW | 422 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 32 | 8.16 kW | 562 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 40 | 10.2 kW | 703 sq ft | $2,553 | $4,317 |

## How Many Zebra Energy ZBR-255M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Zebra Energy ZBR-255M (beta_Voc -0.415%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.19V and beta_Voc=-0.415%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.32 V | 13 panels | 589.2 V | 22 panels |
| **-10 C (14 F)** | 43.74 V | 13 panels | 568.6 V | 22 panels |
| **0 C (32 F)** | 42.15 V | 14 panels | 590.1 V | 23 panels |
| **25 C (77 F STC)** | 38.19 V | 15 panels | 572.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-255M?

Closest cross-brand CEC competitors to Zebra Energy ZBR-255M matched near 255.0 W STC and 38.19 V Voc, led by Changzhou Nesl Solartech DJ-255D/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Changzhou Nesl Solartech DJ-255D/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-255d-c-st15/) Changzhou Nesl Solartech | 255.0 W | Tie (0 W) | 38.19 V | 15.61% | 90.4% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60255**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60255/) GCL System Integration Technology Co Ltd | 255.0 W | Tie (0 W) | 37.7 V | 15.67% | 90.4% |
| [**Advance Power API-M255**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m255/) Advance Power | 255.0 W | Tie (0 W) | 37.68 V | 15.57% | 89.5% |
| [**Eoplly New Energy Technology EP156P/60-255S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156p-60-255s-ac/) Eoplly New Energy Technology | 255.0 W | Tie (0 W) | 37.68 V | 15.6% | 89.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-255M?

Evaluate Zebra Energy ZBR-255M (255.0 W STC, 38.19 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-255M reaches 45.32 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 562 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (562 sq ft).
- 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-255M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Zebra Energy ZBR-255M 8 kW Residential Fit

Needs 32 modules (562 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-255D/C-ST15.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 230.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-255M by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Zebra Energy ZBR-255M?

Multiplying Zebra Energy ZBR-255M's 8.94 A short-circuit current by 1.56 equals 13.95 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Zebra Energy ZBR-255M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.74 V cold Voc at 14 F and handles 8.94 A Isc; string inverters cap Zebra Energy ZBR-255M at 13 panels on 600 V.

### Is Zebra Energy ZBR-255M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Zebra Energy ZBR-255M rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

## Related Pages

Compare Zebra Energy equipment, Changzhou Nesl Solartech DJ-255D/C-ST15 specs, utility payback rates, and NEC string calculators alongside Zebra Energy ZBR-255M.

[All Zebra Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/zebra-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Zebra Energy

- [All Zebra Energy Specs](https://epri-peac.com/solar-equipment/brands/zebra-energy/)
- [Zebra Energy ZBR-305M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-305m/)
- [Zebra Energy ZBR-300P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-300p/)
- [Zebra Energy ZBR-295M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-295m/)
- [Zebra Energy ZBR-290P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-290p/)
- [Zebra Energy ZBR-260P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-260p/)