Zebra Energy ZBR-250MA is a 250.0 W STC (226.0 W PTC) Mono-c-Si solar module ranking #19,686 of 21,677 CEC listings (below all-CEC median; higher than 8.0% of peers). It delivers 15.3% efficiency, 38.07 V Voc at 25 C, and 43.6 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 250.0 W

- **PTC Wattage** : 226.0 W

- **Voc @ 25C** : 38.07 V

- **Efficiency** : 15.3%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Zebra Energy ZBR-250MA Compare Against Peer CEC Listings?

Engineering position of Zebra Energy ZBR-250MA (250.0 W STC) vs. Changzhou Nesl Solartech DJ-250DA/C-ST15 across 5,889 CEC Mono-c-Si solar modules.

Ranking #19,686 across 21,677 CEC solar panels (below all-CEC median; higher than 8.0% of peers), Zebra Energy ZBR-250MA operates as a compact residential or specialty off-grid module sitting 160.0 W below the 410.0 W Mono-c-Si median. Lower 38.07 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters. With typical 90.4% PTC-to-STC thermal output (226.0 W real-world rating), 32 panels occupy 562 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does Zebra Energy ZBR-250MA Fall Across Listed CEC Models?

Plots Zebra Energy ZBR-250MA at 250.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Zebra Energy ZBR-250MA?

Benchmarks Zebra Energy ZBR-250MA on STC wattage, thermal PTC/STC retention, and 15.3 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Zebra Energy ZBR-250MA?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Zebra Energy ZBR-250MA by Zebra Energy.

Rank #19,686 / 21,677

### 250.0 W STC · Higher Than 8.0%

250.0 W STC (-135.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,256

### 15.3% Aperture Efficiency

Power density 153.1 W/m2 (4.61 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.6 V at -10 C (566.8 V string) and 45.18 V at -20 C (13 max).

 8 kW Reference Array

### 32 Panels = 8,000 W STC

Occupies 52.3 m2 (562 sq ft) producing 7,232 W PTC; NEC 690.8 OCPD floor is 13.71 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.07 * (1 + (-0.415/100) * (-10 - 25)) = 43.6 V | OCPD = 1.56 * 8.79 = 13.71 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-250MA: Voc=38.07 V, beta_Voc=-0.415%/C, Isc=8.79 A, STC=250.0 W, Area=1.633 m2.

**Result:** 13 panels max on 600 V (566.8 V); 32 panels for 8 kW (562 sq ft).

## What Are the Published CEC Specifications for Zebra Energy ZBR-250MA?

Laboratory test ratings recorded for Zebra Energy ZBR-250MA (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-250MA.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 250.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 226.0 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.07 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.7 V / 8.14 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.415 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.3% (1.633 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Zebra Energy ZBR-250MA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (562 sq ft at 8 kW), and estimated Year-1 electric bill offset for Zebra Energy ZBR-250MA.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 24 | 6.0 kW | 422 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 32 | 8.0 kW | 562 sq ft | $2,002 | $3,386 |
| **10 kW Class** | 40 | 10.0 kW | 703 sq ft | $2,503 | $4,232 |

## How Many Zebra Energy ZBR-250MA Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Zebra Energy ZBR-250MA (beta_Voc -0.415%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.07V and beta_Voc=-0.415%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.18 V | 13 panels | 587.3 V | 22 panels |
| **-10 C (14 F)** | 43.6 V | 13 panels | 566.8 V | 22 panels |
| **0 C (32 F)** | 42.02 V | 14 panels | 588.3 V | 23 panels |
| **25 C (77 F STC)** | 38.07 V | 15 panels | 571.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-250MA?

Closest cross-brand CEC competitors to Zebra Energy ZBR-250MA matched near 250.0 W STC and 38.07 V Voc, led by Changzhou Nesl Solartech DJ-250DA/C-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Changzhou Nesl Solartech DJ-250DA/C-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-250da-c-st15/) Changzhou Nesl Solartech | 250.0 W | Tie (0 W) | 38.07 V | 15.3% | 90.4% |
| [**Boviet Solar Technology Co Ltd BVM6610P-250**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610p-250/) Boviet Solar Technology Co Ltd | 250.0 W | Tie (0 W) | 37.5 V | 15.37% | 90.2% |
| [**Anji Technology AJP-M660-250**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-250/) Anji Technology | 250.0 W | Tie (0 W) | 37.32 V | 15.4% | 89.0% |
| [**Flextronics FXS-260BB-MAA1B**](https://epri-peac.com/solar-equipment/modules/flextronics/flextronics-fxs-260bb-maa1b/) Flextronics | 252.8 W | +2.8 W | 37.98 V | 15.54% | 90.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-250MA?

Evaluate Zebra Energy ZBR-250MA (250.0 W STC, 38.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-250MA reaches 45.18 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 562 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (562 sq ft).
- 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-250MA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Zebra Energy ZBR-250MA 8 kW Residential Fit

Needs 32 modules (562 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Changzhou Nesl Solartech DJ-250DA/C-ST15.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 226.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-250MA by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### How many Zebra Energy ZBR-250MA panels fit on a 600 V winter solar string?

At -10 C (14 F), Zebra Energy ZBR-250MA cold Voc rises from 38.07 V to 43.6 V (beta_Voc -0.415%/C), capping a 600 V string at 13 panels (566.8 V).

### How much roof area does an 8 kW array of Zebra Energy ZBR-250MA need?

An 8 kW DC system uses 32 Zebra Energy ZBR-250MA modules (8,000 W STC / 7,232 W PTC), covering roughly 562 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

### How does Zebra Energy ZBR-250MA compare against Changzhou Nesl Solartech DJ-250DA/C-ST15?

Zebra Energy ZBR-250MA outputs 250.0 W STC (38.07 V Voc, rank #19,686 of 21,677), while Changzhou Nesl Solartech DJ-250DA/C-ST15 delivers 250.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare Zebra Energy equipment, Changzhou Nesl Solartech DJ-250DA/C-ST15 specs, utility payback rates, and NEC string calculators alongside Zebra Energy ZBR-250MA.

[All Zebra Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/zebra-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Zebra Energy

- [All Zebra Energy Specs](https://epri-peac.com/solar-equipment/brands/zebra-energy/)
- [Zebra Energy ZBR-305M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-305m/)
- [Zebra Energy ZBR-300P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-300p/)
- [Zebra Energy ZBR-295M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-295m/)
- [Zebra Energy ZBR-290P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-290p/)
- [Zebra Energy ZBR-260P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-260p/)