# Zebra Energy ZBR-235P — CEC Solar Module Specifications

Manufacturer: [**Zebra Energy**](https://epri-peac.com/solar-equipment/brands/zebra-energy/) Registry: **CEC Verified Engineering Specification**

Zebra Energy ZBR-235P is a 235.0 W STC (212.2 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.39% efficiency, 36.2 V Voc at 25 C, and 40.99 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 235.0 W

- **PTC Wattage** : 212.2 W

- **Voc @ 25C** : 36.2 V

- **Efficiency** : 14.39%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Zebra Energy ZBR-235P Compare Against Peer CEC Listings?

How Zebra Energy Zebra Energy ZBR-235P handles rooftop heat (212.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Zebra Energy ZBR-235P exhibits 8.8 A short-circuit current, requiring a 13.73 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,368 of 21,677 (43.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.2 m2 for an 8 kW system (43 panels for 10 kW). Lower 36.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

## Where Does Zebra Energy ZBR-235P Fall Across Listed CEC Models?

Where Zebra Energy ZBR-235P (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Zebra Energy ZBR-235P?

Percentile placement of Zebra Energy ZBR-235P across power density (143.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Zebra Energy ZBR-235P?

Four critical engineering numbers homeowners and solar installers check first when reviewing Zebra Energy ZBR-235P specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,368 / 21,677

### 235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,540

### 14.39% Aperture Efficiency

Power density 143.9 W/m2 (5.52 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.99 V at -10 C (573.9 V string) and 42.36 V at -20 C (14 max).

 8 kW Reference Array

### 35 Panels = 8,225 W STC

Occupies 57.2 m2 (615 sq ft) producing 7,427 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.2 * (1 + (-0.378/100) * (-10 - 25)) = 40.99 V | OCPD = 1.56 * 8.8 = 13.73 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-235P: Voc=36.2 V, beta_Voc=-0.378%/C, Isc=8.8 A, STC=235.0 W, Area=1.633 m2.

**Result:** 14 panels max on 600 V (573.9 V); 35 panels for 8 kW (615 sq ft).

## What Are the Published CEC Specifications for Zebra Energy ZBR-235P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Zebra Energy ZBR-235P.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-235P.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 212.2 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.7 V / 7.91 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.378 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.39% (1.633 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many Zebra Energy ZBR-235P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Zebra Energy ZBR-235P (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.11 kW | 457 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 35 | 8.22 kW | 615 sq ft | $2,057 | $3,479 |
| **10 kW Class** | 43 | 10.11 kW | 756 sq ft | $2,530 | $4,279 |

## How Many Zebra Energy ZBR-235P Modules Fit in a Cold-Weather String?

Maximum series module counts for Zebra Energy ZBR-235P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.2V and beta_Voc=-0.378%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.36 V | 14 panels | 593.0 V | 23 panels |
| **-10 C (14 F)** | 40.99 V | 14 panels | 573.9 V | 24 panels |
| **0 C (32 F)** | 39.62 V | 15 panels | 594.3 V | 25 panels |
| **25 C (77 F STC)** | 36.2 V | 16 panels | 579.2 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-235P?

Alternative CEC solar modules from competing brands near Zebra Energy ZBR-235P (235.0 W), including Changzhou Nesl Solartech DJ-235P-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Changzhou Nesl Solartech DJ-235P-ST15**](https://epri-peac.com/solar-equipment/modules/changzhou-nesl-solartech/changzhou-nesl-solartech-dj-235p-st15/) Changzhou Nesl Solartech | 235.0 W | Tie (0 W) | 36.2 V | 14.39% | 90.3% |
| [**Anhui Rinengzhongtian Semiconductor Development QJP235-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjp235-60/) Anhui Rinengzhongtian Semiconductor Development | 235.0 W | Tie (0 W) | 36.1 V | 14.44% | 89.3% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM235-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm235-60/) Anhui Rinengzhongtian Semiconductor Development | 235.0 W | Tie (0 W) | 36.65 V | 14.44% | 90.0% |
| [**Advance Power API-P235**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p235/) Advance Power | 235.0 W | Tie (0 W) | 36.72 V | 14.35% | 89.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-235P?

Evaluate Zebra Energy ZBR-235P (235.0 W STC, 36.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-235P reaches 42.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 615 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (615 sq ft).
- 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-235P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Zebra Energy ZBR-235P 8 kW Residential Fit

Needs 35 modules (615 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Changzhou Nesl Solartech DJ-235P-ST15.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-235P by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Zebra Energy ZBR-235P PTC wattage (212.2 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 212.2 W PTC (90.3% retention) across Zebra Energy ZBR-235P's 1.633 m2 aperture.

### Who should skip Zebra Energy ZBR-235P on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Zebra Energy ZBR-235P panels (615 sq ft) leave unusable roof gaps vs. Changzhou Nesl Solartech DJ-235P-ST15.

### What is the 1,000 V commercial string limit for Zebra Energy ZBR-235P?

On 1,000 V commercial inverters at -10 C (40.99 V cold Voc), Zebra Energy ZBR-235P fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Zebra Energy ZBR-235P.

## Related Pages

Compare Zebra Energy equipment, Changzhou Nesl Solartech DJ-235P-ST15 specs, utility payback rates, and NEC string calculators alongside Zebra Energy ZBR-235P.

[All Zebra Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/zebra-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Zebra Energy

- [All Zebra Energy Specs](https://epri-peac.com/solar-equipment/brands/zebra-energy/)
- [Zebra Energy ZBR-305M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-305m/)
- [Zebra Energy ZBR-300P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-300p/)
- [Zebra Energy ZBR-295M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-295m/)
- [Zebra Energy ZBR-290P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-290p/)
- [Zebra Energy ZBR-260P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-260p/)