title: "Zebra Energy ZBR-190M5 Specs (190.0W, 46.2V Voc)"
url: https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-190m5/
description: "CEC datasheet for Zebra Energy ZBR-190M5: 190.0W STC, 46.2V Voc, 43-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Zebra Energy ZBR-190M5 — CEC Solar Module Specifications

Manufacturer: [**Zebra Energy**](https://epri-peac.com/solar-equipment/brands/zebra-energy/) Registry: **CEC Verified Engineering Specification**

Zebra Energy ZBR-190M5 is a 190.0 W STC (171.9 W PTC) Mono-c-Si solar module ranking #21,132 of 21,677 CEC listings (below all-CEC median; higher than 2.3% of peers). It delivers 14.86% efficiency, 46.2 V Voc at 25 C, and 52.3 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 190.0 W

- **PTC Wattage** : 171.9 W

- **Voc @ 25C** : 46.2 V

- **Efficiency** : 14.86%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Zebra Energy ZBR-190M5 Compare Against Peer CEC Listings?

Solar engineering breakdown for Zebra Energy ZBR-190M5: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Across 5,889 Mono-c-Si listings from Zebra Energy and peers, Zebra Energy ZBR-190M5 stands 220.0 W below the 410.0 W Mono-c-Si median and typical 90.5% PTC-to-STC thermal output (171.9 W real-world rating). Sizing 6 kW (32 panels) to 10 kW (53 panels) yields $1,522-$2,520/yr in baseline US bill offset. Mid-range 46.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does Zebra Energy ZBR-190M5 Fall Across Listed CEC Models?

Distribution marker showing Zebra Energy ZBR-190M5 (190.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Dataset Percentiles Define Zebra Energy ZBR-190M5?

Dataset percentiles tracking Zebra Energy ZBR-190M5 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

## What Do the Dataset Ranks Show for Zebra Energy ZBR-190M5?

Benchmark highlights for Zebra Energy ZBR-190M5 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #21,132 / 21,677

### 190.0 W STC · Higher Than 2.3%

190.0 W STC (-195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,934

### 14.86% Aperture Efficiency

Power density 148.6 W/m2 (5.05 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.3 V at -10 C (575.3 V string) and 54.04 V at -20 C (11 max).

 8 kW Reference Array

### 43 Panels = 8,170 W STC

Occupies 55.0 m2 (592 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 8.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.2 * (1 + (-0.377/100) * (-10 - 25)) = 52.3 V | OCPD = 1.56 * 5.42 = 8.46 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-190M5: Voc=46.2 V, beta_Voc=-0.377%/C, Isc=5.42 A, STC=190.0 W, Area=1.279 m2.

**Result:** 11 panels max on 600 V (575.3 V); 43 panels for 8 kW (592 sq ft).

## What Are the Published CEC Specifications for Zebra Energy ZBR-190M5?

Official CEC datasheet figures for Zebra Energy ZBR-190M5 (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-190M5.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 190.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 171.9 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 46.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 5.42 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.6 V / 4.92 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.377 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.86% (1.279 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Zebra Energy ZBR-190M5 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Zebra Energy ZBR-190M5 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 32 | 6.08 kW | 441 sq ft | $1,522 | $2,573 |
| **8 kW Class** | 43 | 8.17 kW | 592 sq ft | $2,045 | $3,458 |
| **10 kW Class** | 53 | 10.07 kW | 730 sq ft | $2,520 | $4,262 |

## Which Sibling Wattage & Trim Variants Belong to This Zebra Energy Series?

Consolidated Zebra Energy wattage variants sharing the Zebra Energy ZBR-190M5 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Zebra Energy ZBR-190M5 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Zebra Energy ZBR-185M5** | 185.0 W | 167.3 W | 46.1 V | 38.6 V | 14.46% |
| **Zebra Energy ZBR-190M5** | 190.0 W | 171.9 W | 46.2 V | 38.6 V | 14.86% |
| **Zebra Energy ZBR-195M5** | 195.0 W | 176.6 W | 46.1 V | 38.6 V | 15.25% |

## How Many Zebra Energy ZBR-190M5 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Zebra Energy ZBR-190M5 (52.3 V at 14 F).

Computed from Voc=46.2V and beta_Voc=-0.377%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.04 V | 11 panels | 594.4 V | 18 panels |
| **-10 C (14 F)** | 52.3 V | 11 panels | 575.3 V | 19 panels |
| **0 C (32 F)** | 50.55 V | 11 panels | 556.0 V | 19 panels |
| **25 C (77 F STC)** | 46.2 V | 12 panels | 554.4 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-190M5?

Competing CEC solar panels closest to Zebra Energy ZBR-190M5 in nameplate wattage and Voc, starting with JA Solar JAM5(L)-72-190/SI.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**JA Solar JAM5(L)-72-190/SI**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam5-l-72-190-si/) JA Solar | 190.0 W | Tie (0 W) | 45.38 V | 14.88% | 89.2% |
| [**JA Solar JAM5(L)(BK)-72-190/SI**](https://epri-peac.com/solar-equipment/modules/ja-solar/ja-solar-jam5-l-bk-72-190-si/) JA Solar | 190.0 W | Tie (0 W) | 45.38 V | 14.88% | 89.2% |
| [**AXITEC AC-190M/125-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-190m-125-72s/) AXITEC | 190.0 W | Tie (0 W) | 45.23 V | 14.88% | 89.8% |
| [**Suntech Power STP190S-24/Ad**](https://epri-peac.com/solar-equipment/modules/suntech-power/suntech-power-stp190s-24-ad/) Suntech Power | 190.0 W | Tie (0 W) | 45.2 V | 14.88% | 90.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-190M5?

Evaluate Zebra Energy ZBR-190M5 (190.0 W STC, 46.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-190M5 reaches 54.04 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 43 panels for an 8 kW build require 592 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 43 panels (592 sq ft).
- 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-190M5 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Zebra Energy ZBR-190M5 8 kW Residential Fit

Needs 43 modules (592 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare JA Solar JAM5(L)-72-190/SI.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 171.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-190M5 by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Zebra Energy ZBR-190M5?

Multiplying Zebra Energy ZBR-190M5's 5.42 A short-circuit current by 1.56 equals 8.46 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can Zebra Energy ZBR-190M5 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.3 V cold Voc at 14 F and handles 5.42 A Isc; string inverters cap Zebra Energy ZBR-190M5 at 11 panels on 600 V.

### Is Zebra Energy ZBR-190M5 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Zebra Energy ZBR-190M5 rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

## Related Pages

Compare Zebra Energy equipment, JA Solar JAM5(L)-72-190/SI specs, utility payback rates, and NEC string calculators alongside Zebra Energy ZBR-190M5.

[All Zebra Energy Certified Solar Models](https://epri-peac.com/solar-equipment/brands/zebra-energy/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Zebra Energy

- [All Zebra Energy Specs](https://epri-peac.com/solar-equipment/brands/zebra-energy/)
- [Zebra Energy ZBR-305M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-305m/)
- [Zebra Energy ZBR-300P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-300p/)
- [Zebra Energy ZBR-295M](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-295m/)
- [Zebra Energy ZBR-290P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-290p/)
- [Zebra Energy ZBR-260P](https://epri-peac.com/solar-equipment/modules/zebra-energy/zebra-energy-zbr-260p/)