title: "WINAICO WST-270P6 Specs (270.0W, 38.32V Voc)"
url: https://epri-peac.com/solar-equipment/modules/winaico/winaico-wst-270p6/
description: "CEC datasheet for WINAICO WST-270P6: 270.0W STC, 38.32V Voc, 30-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# WINAICO WST-270P6 — CEC Solar Module Specifications

Manufacturer: [**WINAICO**](https://epri-peac.com/solar-equipment/brands/winaico/) Registry: **CEC Verified Engineering Specification**

WINAICO WST-270P6 is a 270.0 W STC (243.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.23% efficiency, 38.32 V Voc at 25 C, and 43.19 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 270.0 W

- **PTC Wattage** : 243.7 W

- **Voc @ 25C** : 38.32 V

- **Efficiency** : 16.23%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WINAICO WST-270P6 Compare Against Peer CEC Listings?

How WINAICO WINAICO WST-270P6 handles rooftop heat (243.7 W PTC), 8 kW sizing, and cold winter string voltage.

WINAICO builds the WINAICO WST-270P6 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). Compared against AXITEC AC-270P/60S (270.0 W), this model holds typical 90.3% PTC-to-STC thermal output (243.7 W real-world rating). Lower 38.32 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.52 A overcurrent floor served by a 15 A breaker.

## Where Does WINAICO WST-270P6 Fall Across Listed CEC Models?

Where WINAICO WST-270P6 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define WINAICO WST-270P6?

Percentile placement of WINAICO WST-270P6 across power density (162.4 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for WINAICO WST-270P6?

Four critical engineering numbers homeowners and solar installers check first when reviewing WINAICO WST-270P6 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #18,572 / 21,677

### 270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,776

### 16.23% Aperture Efficiency

Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.19 V at -10 C (561.5 V string) and 44.58 V at -20 C (13 max).

 8 kW Reference Array

### 30 Panels = 8,100 W STC

Occupies 49.9 m2 (537 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 14.52 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.32 * (1 + (-0.363/100) * (-10 - 25)) = 43.19 V | OCPD = 1.56 * 9.31 = 14.52 A

Inputs from CEC Modules.csv for WINAICO WST-270P6: Voc=38.32 V, beta_Voc=-0.363%/C, Isc=9.31 A, STC=270.0 W, Area=1.663 m2.

**Result:** 13 panels max on 600 V (561.5 V); 30 panels for 8 kW (537 sq ft).

## What Are the Published CEC Specifications for WINAICO WST-270P6?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WINAICO WST-270P6. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for WINAICO WST-270P6.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 243.7 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.27 V / 8.65 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.363 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.23% (1.663 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WINAICO WST-270P6 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WINAICO WST-270P6 (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 23 | 6.21 kW | 412 sq ft | $1,554 | $2,628 |
| **8 kW Class** | 30 | 8.1 kW | 537 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 38 | 10.26 kW | 680 sq ft | $2,568 | $4,342 |

## Which Sibling Wattage & Trim Variants Belong to This WINAICO Series?

All closely matched WINAICO wattages and cosmetic trims sharing the WINAICO WST-270P6 architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the WINAICO WST-270P6 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WINAICO WST-265P6** | 265.0 W | 239.0 W | 38.1 V | 31.26 V | 15.93% |
| **WINAICO WST-270P6** | 270.0 W | 243.7 W | 38.32 V | 31.27 V | 16.23% |

## How Many WINAICO WST-270P6 Modules Fit in a Cold-Weather String?

Maximum series module counts for WINAICO WST-270P6 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.32V and beta_Voc=-0.363%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.58 V | 13 panels | 579.5 V | 22 panels |
| **-10 C (14 F)** | 43.19 V | 13 panels | 561.5 V | 23 panels |
| **0 C (32 F)** | 41.8 V | 14 panels | 585.2 V | 23 panels |
| **25 C (77 F STC)** | 38.32 V | 15 panels | 574.8 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to WINAICO WST-270P6?

Alternative CEC solar modules from competing brands near WINAICO WST-270P6 (270.0 W), including AXITEC AC-270P/60S. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AXITEC AC-270P/60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-270p-60s/) AXITEC | 270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
| [**AXITEC AC-270P/60V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-270p-60v/) AXITEC | 270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
| [**GCL System Integration Technology Co Ltd GCL-P6/60270**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-p6-60270/) GCL System Integration Technology Co Ltd | 270.0 W | Tie (0 W) | 38.3 V | 16.6% | 90.6% |
| [**Bluesun Solar Energy Tech CoLtd BSM270M-60**](https://epri-peac.com/solar-equipment/modules/bluesun-solar-energy-tech-coltd/bluesun-solar-energy-tech-coltd-bsm270m-60/) Bluesun Solar Energy Tech CoLtd | 270.0 W | Tie (0 W) | 38.46 V | 16.6% | 89.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WINAICO WST-270P6?

Evaluate WINAICO WST-270P6 (270.0 W STC, 38.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WINAICO WST-270P6 reaches 44.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (537 sq ft).
- 2026 tax credit baseline: cash residential installs of WINAICO WST-270P6 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WINAICO WST-270P6 8 kW Residential Fit

Needs 30 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-270P/60S.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 243.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WINAICO WST-270P6 by WINAICO grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

### What fuse or breaker size does NEC 690.8 require for WINAICO WST-270P6?

Multiplying WINAICO WST-270P6's 9.31 A short-circuit current by 1.56 equals 14.52 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for WINAICO WST-270P6 before finalizing component orders.

### Can WINAICO WST-270P6 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.19 V cold Voc at 14 F and handles 9.31 A Isc; string inverters cap WINAICO WST-270P6 at 13 panels on 600 V.

### Is WINAICO WST-270P6 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WINAICO WST-270P6 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare WINAICO equipment, AXITEC AC-270P/60S specs, utility payback rates, and NEC string calculators alongside WINAICO WST-270P6. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

[All WINAICO Certified Solar Models](https://epri-peac.com/solar-equipment/brands/winaico/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WINAICO

- [All WINAICO Specs](https://epri-peac.com/solar-equipment/brands/winaico/)
- [WINAICO WSP-335MX](https://epri-peac.com/solar-equipment/modules/winaico/winaico-wsp-335mx/)
- [WINAICO WSP-310M6](https://epri-peac.com/solar-equipment/modules/winaico/winaico-wsp-310m6/)
- [WINAICO WSP-310MX](https://epri-peac.com/solar-equipment/modules/winaico/winaico-wsp-310mx/)
- [WINAICO WSP-295MX](https://epri-peac.com/solar-equipment/modules/winaico/winaico-wsp-295mx/)
- [WINAICO WST-290M6](https://epri-peac.com/solar-equipment/modules/winaico/winaico-wst-290m6/)