# WAAREE ENERGIES LIMITED WU-220 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WU-220 is a 220.0 W STC (195.6 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.28% efficiency, 36.0 V Voc at 25 C, and 40.51 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 220.0 W

- **PTC Wattage** : 195.6 W

- **Voc @ 25C** : 36.0 V

- **Efficiency** : 13.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WU-220 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WU-220: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 220.0 W STC and 195.6 W PTC, WAAREE ENERGIES LIMITED WU-220 sits -165.0 W vs all-CEC median (below all-CEC median; higher than 3.8% of peers) among 21,677 listed modules. Power density reaches 132.8 W/m2 (6.63 percentage points below 19.91% CEC median). Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Alps Technology ATI-M660-220 rates 220.0 W.

## Where Does WAAREE ENERGIES LIMITED WU-220 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WU-220 (220.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-220?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WU-220 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-220?

Benchmark highlights for WAAREE ENERGIES LIMITED WU-220 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,759 / 21,677

### 220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,329

### 13.28% Aperture Efficiency

Power density 132.8 W/m2 (6.63 percentage points below 19.91% CEC median). PTC/STC ratio: 88.9% (rank #20,819).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.51 V at -10 C (567.1 V string) and 41.8 V at -20 C (14 max).

 8 kW Reference Array

### 37 Panels = 8,140 W STC

Occupies 61.3 m2 (660 sq ft) producing 7,237 W PTC; NEC 690.8 OCPD floor is 12.95 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.358/100) * (-10 - 25)) = 40.51 V | OCPD = 1.56 * 8.3 = 12.95 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-220: Voc=36.0 V, beta_Voc=-0.358%/C, Isc=8.3 A, STC=220.0 W, Area=1.657 m2.

**Result:** 14 panels max on 600 V (567.1 V); 37 panels for 8 kW (660 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-220?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WU-220 (Multi-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-220.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 195.6 W (88.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.0 V / 7.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.358 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.28% (1.657 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WU-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WU-220 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 28 | 6.16 kW | 499 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 37 | 8.14 kW | 660 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 46 | 10.12 kW | 820 sq ft | $2,533 | $4,283 |

## Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WU-220 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WU-220 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WAAREE ENERGIES LIMITED WU-210** | 210.0 W | 186.4 W | 36.0 V | 29.0 V | 12.67% |
| **WAAREE ENERGIES LIMITED WU-220** | 220.0 W | 195.6 W | 36.0 V | 29.0 V | 13.28% |

## How Many WAAREE ENERGIES LIMITED WU-220 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WU-220 (40.51 V at 14 F).

Computed from Voc=36.0V and beta_Voc=-0.358%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.8 V | 14 panels | 585.2 V | 23 panels |
| **-10 C (14 F)** | 40.51 V | 14 panels | 567.1 V | 24 panels |
| **0 C (32 F)** | 39.22 V | 15 panels | 588.3 V | 25 panels |
| **25 C (77 F STC)** | 36.0 V | 16 panels | 576.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-220?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WU-220 in nameplate wattage and Voc, starting with Alps Technology ATI-M660-220.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Alps Technology ATI-M660-220**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-m660-220/) Alps Technology | 220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| [**Anji Technology AJP-M660-220**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-220/) Anji Technology | 220.0 W | Tie (0 W) | 36.06 V | 13.55% | 86.0% |
| [**Centrosolar America DP60 220**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp60-220/) Centrosolar America | 220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM220-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm220-60/) Anhui Rinengzhongtian Semiconductor Development | 220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-220?

Evaluate WAAREE ENERGIES LIMITED WU-220 (220.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-220 reaches 41.8 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 660 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (660 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WU-220 8 kW Residential Fit

Needs 37 modules (660 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Alps Technology ATI-M660-220.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 195.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-220 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### How many WAAREE ENERGIES LIMITED WU-220 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED WU-220 cold Voc rises from 36.0 V to 40.51 V (beta_Voc -0.358%/C), capping a 600 V string at 14 panels (567.1 V).

### How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WU-220 need?

An 8 kW DC system uses 37 WAAREE ENERGIES LIMITED WU-220 modules (8,140 W STC / 7,237 W PTC), covering roughly 660 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

### How does WAAREE ENERGIES LIMITED WU-220 compare against Alps Technology ATI-M660-220?

WAAREE ENERGIES LIMITED WU-220 outputs 220.0 W STC (36.0 V Voc, rank #20,759 of 21,677), while Alps Technology ATI-M660-220 delivers 220.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Alps Technology ATI-M660-220 specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WU-220.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)