# WAAREE ENERGIES LIMITED WU-180 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WU-180 is a 180.0 W STC (159.7 W PTC) Multi-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 12.2% efficiency, 32.0 V Voc at 25 C, and 36.01 V cold Voc at -10 C (16 panels max per 600 V string).

- **STC Wattage** : 180.0 W

- **PTC Wattage** : 159.7 W

- **Voc @ 25C** : 32.0 V

- **Efficiency** : 12.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WU-180 Compare Against Peer CEC Listings?

Engineering position of WAAREE ENERGIES LIMITED WU-180 (180.0 W STC) vs. Mitsubishi Electric PV-MF180UD4 across 1,407 CEC Multi-c-Si solar modules.

Ranking #21,232 across 21,677 CEC solar panels (below all-CEC median; higher than 1.8% of peers), WAAREE ENERGIES LIMITED WU-180 operates as a compact residential or specialty off-grid module sitting 98.8 W below the 278.8 W Multi-c-Si median. Lower 32.0 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters. With typical 88.7% PTC-to-STC thermal output (159.7 W real-world rating), 45 panels occupy 714 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does WAAREE ENERGIES LIMITED WU-180 Fall Across Listed CEC Models?

Plots WAAREE ENERGIES LIMITED WU-180 at 180.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-180?

Benchmarks WAAREE ENERGIES LIMITED WU-180 on STC wattage, thermal PTC/STC retention, and 12.2 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-180?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for WAAREE ENERGIES LIMITED WU-180 by WAAREE ENERGIES LIMITED.

Rank #21,232 / 21,677

### 180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,561

### 12.2% Aperture Efficiency

Power density 122.0 W/m2 (7.71 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

### 16 Panels Max @ -10 C (600 V)

Cold Voc reaches 36.01 V at -10 C (576.2 V string) and 37.16 V at -20 C (16 max).

 8 kW Reference Array

### 45 Panels = 8,100 W STC

Occupies 66.4 m2 (714 sq ft) producing 7,186 W PTC; NEC 690.8 OCPD floor is 12.17 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 32.0 * (1 + (-0.358/100) * (-10 - 25)) = 36.01 V | OCPD = 1.56 * 7.8 = 12.17 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-180: Voc=32.0 V, beta_Voc=-0.358%/C, Isc=7.8 A, STC=180.0 W, Area=1.475 m2.

**Result:** 16 panels max on 600 V (576.2 V); 45 panels for 8 kW (714 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-180?

Laboratory test ratings recorded for WAAREE ENERGIES LIMITED WU-180 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-180.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 180.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 159.7 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 32.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 7.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 26.0 V / 6.9 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.358 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.2% (1.475 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WU-180 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (714 sq ft at 8 kW), and estimated Year-1 electric bill offset for WAAREE ENERGIES LIMITED WU-180.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 34 | 6.12 kW | 540 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 45 | 8.1 kW | 714 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 56 | 10.08 kW | 889 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Sibling wattage bins and frame colors grouped with WAAREE ENERGIES LIMITED WU-180 under WAAREE ENERGIES LIMITED to prevent duplicate spec pages.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WU-180 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WAAREE ENERGIES LIMITED WU-175** | 175.0 W | 155.1 W | 32.0 V | 26.0 V | 11.86% |
| **WAAREE ENERGIES LIMITED WU-180** | 180.0 W | 159.7 W | 32.0 V | 26.0 V | 12.2% |

## How Many WAAREE ENERGIES LIMITED WU-180 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for WAAREE ENERGIES LIMITED WU-180 (beta_Voc -0.358%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=32.0V and beta_Voc=-0.358%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 37.16 V | 16 panels | 594.6 V | 26 panels |
| **-10 C (14 F)** | 36.01 V | 16 panels | 576.2 V | 27 panels |
| **0 C (32 F)** | 34.86 V | 17 panels | 592.6 V | 28 panels |
| **25 C (77 F STC)** | 32.0 V | 18 panels | 576.0 V | 31 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-180?

Closest cross-brand CEC competitors to WAAREE ENERGIES LIMITED WU-180 matched near 180.0 W STC and 32.0 V Voc, led by Mitsubishi Electric PV-MF180UD4.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Mitsubishi Electric PV-MF180UD4**](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-mf180ud4/) Mitsubishi Electric | 180.0 W | Tie (0 W) | 30.4 V | 13.0% | 89.3% |
| [**Hanwha Qcells (Qidong) Co Ltd SF190-27-P185**](https://epri-peac.com/solar-equipment/modules/hanwha-qcells-qidong-co-ltd/hanwha-qcells-qidong-co-ltd-sf190-27-p185/) Hanwha Qcells (Qidong) Co Ltd | 185.0 W | +5.0 W | 32.5 V | 12.38% | 88.6% |
| [**Gintung Energy ASEC-180G6S**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-180g6s/) Gintung Energy | 180.0 W | Tie (0 W) | 29.73 V | 13.8% | 88.7% |
| [**APOS Energy AP180**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-ap180/) APOS Energy | 180.0 W | Tie (0 W) | 29.72 V | 13.42% | 88.9% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-180?

Evaluate WAAREE ENERGIES LIMITED WU-180 (180.0 W STC, 32.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-180 reaches 37.16 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 45 panels for an 8 kW build require 714 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (714 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-180 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WU-180 8 kW Residential Fit

Needs 45 modules (714 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare Mitsubishi Electric PV-MF180UD4.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 159.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-180 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### How many WAAREE ENERGIES LIMITED WU-180 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED WU-180 cold Voc rises from 32.0 V to 36.01 V (beta_Voc -0.358%/C), capping a 600 V string at 16 panels (576.2 V).

### How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WU-180 need?

An 8 kW DC system uses 45 WAAREE ENERGIES LIMITED WU-180 modules (8,100 W STC / 7,186 W PTC), covering roughly 714 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

### How does WAAREE ENERGIES LIMITED WU-180 compare against Mitsubishi Electric PV-MF180UD4?

WAAREE ENERGIES LIMITED WU-180 outputs 180.0 W STC (32.0 V Voc, rank #21,232 of 21,677), while Mitsubishi Electric PV-MF180UD4 delivers 180.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Mitsubishi Electric PV-MF180UD4 specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WU-180.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)