WAAREE ENERGIES LIMITED WU-120 is a 120.0 W STC (106.4 W PTC) Multi-c-Si solar module ranking #21,493 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 12.2% efficiency, 21.0 V Voc at 25 C, and 23.63 V cold Voc at -10 C (25 panels max per 600 V string).

- **STC Wattage** : 120.0 W

- **PTC Wattage** : 106.4 W

- **Voc @ 25C** : 21.0 V

- **Efficiency** : 12.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WU-120 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for WAAREE ENERGIES LIMITED WU-120 (Multi-c-Si) residential solar systems.

Homeowners evaluating WAAREE ENERGIES LIMITED WU-120 need 50 panels for 6 kW or 67 panels (709 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 67 panels (709 sq ft). Under NEC 690.7(A), beta_Voc (-0.358%/C) pushes open-circuit voltage to 23.63 V at 14 F and 24.38 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does WAAREE ENERGIES LIMITED WU-120 Fall Across Listed CEC Models?

Comparison of WAAREE ENERGIES LIMITED WU-120 (120.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-120?

Relative ranking of WAAREE ENERGIES LIMITED WU-120 across nameplate watts, 88.7% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-120?

Summary of WAAREE ENERGIES LIMITED WU-120 output rank, 8 kW array size (67 panels), efficiency rating, and 600 V string limit.

Rank #21,493 / 21,677

### 120.0 W STC · Higher Than 0.8%

120.0 W STC (-265.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,561

### 12.2% Aperture Efficiency

Power density 122.1 W/m2 (7.71 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).

NEC 690.7 Limit

### 25 Panels Max @ -10 C (600 V)

Cold Voc reaches 23.63 V at -10 C (590.8 V string) and 24.38 V at -20 C (24 max).

 8 kW Reference Array

### 67 Panels = 8,040 W STC

Occupies 65.9 m2 (709 sq ft) producing 7,129 W PTC; NEC 690.8 OCPD floor is 12.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 21.0 * (1 + (-0.358/100) * (-10 - 25)) = 23.63 V | OCPD = 1.56 * 8.0 = 12.48 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-120: Voc=21.0 V, beta_Voc=-0.358%/C, Isc=8.0 A, STC=120.0 W, Area=0.983 m2.

**Result:** 25 panels max on 600 V (590.8 V); 67 panels for 8 kW (709 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-120?

Complete CEC test sheet for WAAREE ENERGIES LIMITED WU-120 including Isc (8.0 A), Voc (21.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-120.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 120.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 106.4 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 21.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 17.0 V / 7.1 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.358 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 12.2% (0.983 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WU-120 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using WAAREE ENERGIES LIMITED WU-120.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 50 | 6.0 kW | 529 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 67 | 8.04 kW | 709 sq ft | $2,012 | $3,403 |
| **10 kW Class** | 84 | 10.08 kW | 889 sq ft | $2,523 | $4,266 |

## How Many WAAREE ENERGIES LIMITED WU-120 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for WAAREE ENERGIES LIMITED WU-120 (21.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=21.0V and beta_Voc=-0.358%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 24.38 V | 24 panels | 585.1 V | 41 panels |
| **-10 C (14 F)** | 23.63 V | 25 panels | 590.8 V | 42 panels |
| **0 C (32 F)** | 22.88 V | 26 panels | 594.9 V | 43 panels |
| **25 C (77 F STC)** | 21.0 V | 28 panels | 588.0 V | 47 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-120?

Four comparable CEC modules such as Gintung Energy ASEC-120G6M (120.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Gintung Energy ASEC-120G6M**](https://epri-peac.com/solar-equipment/modules/gintung-energy/gintung-energy-asec-120g6m/) Gintung Energy | 120.0 W | Tie (0 W) | 21.6 V | 12.21% | 89.1% |
| [**Mitsubishi Electric PV-EE120MF5F**](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-ee120mf5f/) Mitsubishi Electric | 120.0 W | Tie (0 W) | 21.6 V | 11.91% | 90.6% |
| [**United Renewable Energy Co Ltd D6P120A1F**](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-d6p120a1f/) United Renewable Energy Co Ltd | 120.0 W | Tie (0 W) | 21.6 V | 12.21% | 89.1% |
| [**Mitsubishi Electric PV-EE130MF5F**](https://epri-peac.com/solar-equipment/modules/mitsubishi-electric/mitsubishi-electric-pv-ee130mf5f/) Mitsubishi Electric | 130.0 W | +10.0 W | 21.9 V | 12.9% | 90.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-120?

Evaluate WAAREE ENERGIES LIMITED WU-120 (120.0 W STC, 21.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-120 reaches 24.38 V per panel—exceeding 24 panels in series voids 600 V inverter warranties.
- Footprint constraint: 67 panels for an 8 kW build require 709 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 67 panels (709 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-120 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WU-120 8 kW Residential Fit

Needs 67 modules (709 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 25 panels (-10 C) or 24 panels (-20 C), or compare Gintung Energy ASEC-120G6M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 106.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-120 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is WAAREE ENERGIES LIMITED WU-120 PTC wattage (106.4 W) lower than STC (120.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 106.4 W PTC (88.7% retention) across WAAREE ENERGIES LIMITED WU-120's 0.983 m2 aperture.

### Who should skip WAAREE ENERGIES LIMITED WU-120 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 67 WAAREE ENERGIES LIMITED WU-120 panels (709 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-120G6M.

### What is the 1,000 V commercial string limit for WAAREE ENERGIES LIMITED WU-120?

On 1,000 V commercial inverters at -10 C (23.63 V cold Voc), WAAREE ENERGIES LIMITED WU-120 fits up to 42 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WAAREE ENERGIES LIMITED WU-120.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Gintung Energy ASEC-120G6M specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WU-120.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)