title: "WAAREE ENERGIES LIMITED WSM-340 Specs (340.0W, 47.15V Voc)"
url: https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-wsm-340/
description: "CEC datasheet for WAAREE ENERGIES LIMITED WSM-340: 340.0W STC, 47.15V Voc, 24-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# WAAREE ENERGIES LIMITED WSM-340 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WSM-340 is a 340.0 W STC (311.3 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.71% efficiency, 47.15 V Voc at 25 C, and 52.45 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 340.0 W

- **PTC Wattage** : 311.3 W

- **Voc @ 25C** : 47.15 V

- **Efficiency** : 17.71%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WSM-340 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WSM-340 handles rooftop heat (311.3 W PTC), 8 kW sizing, and cold winter string voltage.

WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED WSM-340 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 177.1 W/m2 (2.20 percentage points below 19.91% CEC median). Compared against Advance Power API-M340 (340.0 W), this model holds strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677). Mid-range 47.15 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.82 A overcurrent floor served by a 15 A breaker.

## Where Does WAAREE ENERGIES LIMITED WSM-340 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED WSM-340 (340.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSM-340?

Percentile placement of WAAREE ENERGIES LIMITED WSM-340 across power density (177.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSM-340?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WSM-340 specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #13,575 / 21,677

### 340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,498

### 17.71% Aperture Efficiency

Power density 177.1 W/m2 (2.20 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.45 V at -10 C (577.0 V string) and 53.96 V at -20 C (11 max).

 8 kW Reference Array

### 24 Panels = 8,160 W STC

Occupies 46.1 m2 (496 sq ft) producing 7,471 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.15 * (1 + (-0.321/100) * (-10 - 25)) = 52.45 V | OCPD = 1.56 * 9.5 = 14.82 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSM-340: Voc=47.15 V, beta_Voc=-0.321%/C, Isc=9.5 A, STC=340.0 W, Area=1.92 m2.

**Result:** 11 panels max on 600 V (577.0 V); 24 panels for 8 kW (496 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSM-340?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WSM-340.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSM-340.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 311.3 W (91.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.15 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.1 V / 8.93 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.321 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.71% (1.92 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WSM-340 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WSM-340 (340.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 18 | 6.12 kW | 372 sq ft | $1,532 | $2,590 |
| **8 kW Class** | 24 | 8.16 kW | 496 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 30 | 10.2 kW | 620 sq ft | $2,553 | $4,317 |

## Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WSM-340 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSM-340 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WAAREE ENERGIES LIMITED WSM-330** | 330.0 W | 301.8 W | 46.9 V | 37.7 V | 17.19% |
| **WAAREE ENERGIES LIMITED WSM-335** | 335.0 W | 306.5 W | 47.05 V | 37.9 V | 17.45% |
| **WAAREE ENERGIES LIMITED WSM-340** | 340.0 W | 311.3 W | 47.15 V | 38.1 V | 17.71% |
| **WAAREE ENERGIES LIMITED WSM-345** | 345.0 W | 316.0 W | 47.25 V | 38.3 V | 17.97% |

## How Many WAAREE ENERGIES LIMITED WSM-340 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED WSM-340 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.15V and beta_Voc=-0.321%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.96 V | 11 panels | 593.6 V | 18 panels |
| **-10 C (14 F)** | 52.45 V | 11 panels | 577.0 V | 19 panels |
| **0 C (32 F)** | 50.93 V | 11 panels | 560.2 V | 19 panels |
| **25 C (77 F STC)** | 47.15 V | 12 panels | 565.8 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSM-340?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WSM-340 (340.0 W), including Advance Power API-M340.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-M340**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m340/) Advance Power | 340.0 W | Tie (0 W) | 47.18 V | 17.53% | 91.7% |
| [**DEHUI SOLAR POWER INC DH-72M-340W**](https://epri-peac.com/solar-equipment/modules/dehui-solar-power-inc/dehui-solar-power-inc-dh-72m-340w/) DEHUI SOLAR POWER INC | 340.0 W | Tie (0 W) | 47.3 V | 17.68% | 91.3% |
| [**Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development-co-ltd/anhui-rinengzhongtian-semiconductor-development-co-ltd-qjm340-72/) Anhui Rinengzhongtian Semiconductor Development Co Ltd | 340.0 W | Tie (0 W) | 46.97 V | 17.52% | 91.0% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m-340w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 340.0 W | Tie (0 W) | 46.91 V | 17.68% | 91.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSM-340?

Evaluate WAAREE ENERGIES LIMITED WSM-340 (340.0 W STC, 47.15 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSM-340 reaches 53.96 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSM-340 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WSM-340 8 kW Residential Fit

Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M340.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 311.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSM-340 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSM-340?

Multiplying WAAREE ENERGIES LIMITED WSM-340's 9.5 A short-circuit current by 1.56 equals 14.82 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can WAAREE ENERGIES LIMITED WSM-340 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.45 V cold Voc at 14 F and handles 9.5 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSM-340 at 11 panels on 600 V.

### Is WAAREE ENERGIES LIMITED WSM-340 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSM-340 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Advance Power API-M340 specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WSM-340.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)