title: "WAAREE ENERGIES LIMITED WSM-140 Specs (140.0W, 21.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-wsm-140/
description: "CEC datasheet for WAAREE ENERGIES LIMITED WSM-140: 140.0W STC, 21.0V Voc, 58-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# WAAREE ENERGIES LIMITED WSM-140 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WSM-140 is a 140.0 W STC (123.4 W PTC) Mono-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 13.92% efficiency, 21.0 V Voc at 25 C, and 23.48 V cold Voc at -10 C (25 panels max per 600 V string).

- **STC Wattage** : 140.0 W

- **PTC Wattage** : 123.4 W

- **Voc @ 25C** : 21.0 V

- **Efficiency** : 13.92%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WSM-140 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WSM-140: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED WSM-140 stands 270.0 W below the 410.0 W Mono-c-Si median and typical 88.1% PTC-to-STC thermal output (123.4 W real-world rating). Sizing 6 kW (43 panels) to 10 kW (72 panels) yields $1,507-$2,523/yr in baseline US bill offset. Lower 21.0 V string voltage fits 25 panels in series at 14 F and pairs easily with microinverters.

## Where Does WAAREE ENERGIES LIMITED WSM-140 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WSM-140 (140.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WSM-140?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WSM-140 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WSM-140?

Benchmark highlights for WAAREE ENERGIES LIMITED WSM-140 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,440 / 21,677

### 140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,945

### 13.92% Aperture Efficiency

Power density 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). PTC/STC ratio: 88.1% (rank #21,362).

NEC 690.7 Limit

### 25 Panels Max @ -10 C (600 V)

Cold Voc reaches 23.48 V at -10 C (587.0 V string) and 24.19 V at -20 C (24 max).

 8 kW Reference Array

### 58 Panels = 8,120 W STC

Occupies 58.3 m2 (628 sq ft) producing 7,157 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 21.0 * (1 + (-0.338/100) * (-10 - 25)) = 23.48 V | OCPD = 1.56 * 8.89 = 13.87 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WSM-140: Voc=21.0 V, beta_Voc=-0.338%/C, Isc=8.89 A, STC=140.0 W, Area=1.006 m2.

**Result:** 25 panels max on 600 V (587.0 V); 58 panels for 8 kW (628 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WSM-140?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WSM-140 (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WSM-140.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 123.4 W (88.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 21.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 17.0 V / 8.24 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.338 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.92% (1.006 m2) | Array roof footprint density |
| **Cell Count & Technology** | 36 cells (Mono-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WSM-140 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WSM-140 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 43 | 6.02 kW | 466 sq ft | $1,507 | $2,548 |
| **8 kW Class** | 58 | 8.12 kW | 628 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 72 | 10.08 kW | 780 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WSM-140 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WSM-140 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WAAREE ENERGIES LIMITED WSM-135** | 135.0 W | 118.8 W | 21.0 V | 17.0 V | 13.42% |
| **WAAREE ENERGIES LIMITED WSM-140** | 140.0 W | 123.4 W | 21.0 V | 17.0 V | 13.92% |
| **WAAREE ENERGIES LIMITED WSM-145** | 145.0 W | 127.9 W | 21.0 V | 17.0 V | 14.42% |

## How Many WAAREE ENERGIES LIMITED WSM-140 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WSM-140 (23.48 V at 14 F).

Computed from Voc=21.0V and beta_Voc=-0.338%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 24.19 V | 24 panels | 580.6 V | 41 panels |
| **-10 C (14 F)** | 23.48 V | 25 panels | 587.0 V | 42 panels |
| **0 C (32 F)** | 22.77 V | 26 panels | 592.0 V | 43 panels |
| **25 C (77 F STC)** | 21.0 V | 28 panels | 588.0 V | 47 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WSM-140?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WSM-140 in nameplate wattage and Voc, starting with Auxin Solar AXN6M409T140.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Auxin Solar AXN6M409T140**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m409t140/) Auxin Solar | 140.0 W | Tie (0 W) | 22.03 V | 14.29% | 89.3% |
| [**Centrosolar America DP36 140**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp36-140/) Centrosolar America | 140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| [**Solartech Energy ASC-6P-36-140**](https://epri-peac.com/solar-equipment/modules/solartech-energy/solartech-energy-asc-6p-36-140/) Solartech Energy | 140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |
| [**US Solar USS-QCMI2-36-140**](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-36-140/) US Solar | 140.0 W | Tie (0 W) | 22.15 V | 13.85% | 88.4% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WSM-140?

Evaluate WAAREE ENERGIES LIMITED WSM-140 (140.0 W STC, 21.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WSM-140 reaches 24.19 V per panel—exceeding 24 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WSM-140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WSM-140 8 kW Residential Fit

Needs 58 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 25 panels (-10 C) or 24 panels (-20 C), or compare Auxin Solar AXN6M409T140.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 123.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WSM-140 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WSM-140?

Multiplying WAAREE ENERGIES LIMITED WSM-140's 8.89 A short-circuit current by 1.56 equals 13.87 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can WAAREE ENERGIES LIMITED WSM-140 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 23.48 V cold Voc at 14 F and handles 8.89 A Isc; string inverters cap WAAREE ENERGIES LIMITED WSM-140 at 25 panels on 600 V.

### Is WAAREE ENERGIES LIMITED WSM-140 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WSM-140 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Auxin Solar AXN6M409T140 specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WSM-140.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)