# WAAREE ENERGIES LIMITED WS-310 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WS-310 is a 310.0 W STC (279.4 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.15% efficiency, 46.3 V Voc at 25 C, and 52.3 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 279.4 W

- **Voc @ 25C** : 46.3 V

- **Efficiency** : 16.15%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WS-310 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WS-310 handles rooftop heat (279.4 W PTC), 8 kW sizing, and cold winter string voltage.

WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED WS-310 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 161.5 W/m2 (3.76 percentage points below 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM6612P-310 (310.0 W), this model holds typical 90.1% PTC-to-STC thermal output (279.4 W real-world rating). Mid-range 46.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.88 A overcurrent floor served by a 15 A breaker.

## Where Does WAAREE ENERGIES LIMITED WS-310 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED WS-310 (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WS-310?

Percentile placement of WAAREE ENERGIES LIMITED WS-310 across power density (161.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WS-310?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WS-310 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,916

### 16.15% Aperture Efficiency

Power density 161.5 W/m2 (3.76 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.3 V at -10 C (575.3 V string) and 54.01 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 49.9 m2 (537 sq ft) producing 7,264 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.3 * (1 + (-0.37/100) * (-10 - 25)) = 52.3 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WS-310: Voc=46.3 V, beta_Voc=-0.37%/C, Isc=8.9 A, STC=310.0 W, Area=1.92 m2.

**Result:** 11 panels max on 600 V (575.3 V); 26 panels for 8 kW (537 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WS-310?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WS-310.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WS-310.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 279.4 W (90.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 46.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.35 V / 8.3 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.37 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.15% (1.92 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WS-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WS-310 (310.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 413 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 537 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 682 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

All closely matched WAAREE ENERGIES LIMITED wattages and cosmetic trims sharing the WAAREE ENERGIES LIMITED WS-310 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WS-310 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WAAREE ENERGIES LIMITED WS-300** | 300.0 W | 270.2 W | 46.1 V | 37.05 V | 15.62% |
| **WAAREE ENERGIES LIMITED WS-305** | 305.0 W | 274.8 W | 46.2 V | 37.2 V | 15.89% |
| **WAAREE ENERGIES LIMITED WS-310** | 310.0 W | 279.4 W | 46.3 V | 37.35 V | 16.15% |
| **WAAREE ENERGIES LIMITED WS-315** | 315.0 W | 284.1 W | 46.4 V | 37.5 V | 16.41% |
| **WAAREE ENERGIES LIMITED WS-320** | 320.0 W | 288.7 W | 46.5 V | 37.65 V | 16.67% |

## How Many WAAREE ENERGIES LIMITED WS-310 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED WS-310 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.3V and beta_Voc=-0.37%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 54.01 V | 11 panels | 594.1 V | 18 panels |
| **-10 C (14 F)** | 52.3 V | 11 panels | 575.3 V | 19 panels |
| **0 C (32 F)** | 50.58 V | 11 panels | 556.4 V | 19 panels |
| **25 C (77 F STC)** | 46.3 V | 12 panels | 555.6 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WS-310?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WS-310 (310.0 W), including Boviet Solar Technology Co Ltd BVM6612P-310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM6612P-310**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612p-310/) Boviet Solar Technology Co Ltd | 310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| [**Centrosolar America CP72 310-C1**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-cp72-310-c1/) Centrosolar America | 310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| [**BYD Company Limited BYD 310P6C-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-310p6c-36/) BYD Company Limited | 310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.2% |
| [**BYD Company Limited BYD310P6K-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd310p6k-36/) BYD Company Limited | 310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WS-310?

Evaluate WAAREE ENERGIES LIMITED WS-310 (310.0 W STC, 46.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WS-310 reaches 54.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (537 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WS-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WS-310 8 kW Residential Fit

Needs 26 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WS-310 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WS-310?

Multiplying WAAREE ENERGIES LIMITED WS-310's 8.9 A short-circuit current by 1.56 equals 13.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can WAAREE ENERGIES LIMITED WS-310 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.3 V cold Voc at 14 F and handles 8.9 A Isc; string inverters cap WAAREE ENERGIES LIMITED WS-310 at 11 panels on 600 V.

### Is WAAREE ENERGIES LIMITED WS-310 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WS-310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Boviet Solar Technology Co Ltd BVM6612P-310 specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WS-310.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)