# WAAREE ENERGIES LIMITED WS-280 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WS-280 is a 280.0 W STC (254.2 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.28% efficiency, 38.3 V Voc at 25 C, and 43.25 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 280.0 W

- **PTC Wattage** : 254.2 W

- **Voc @ 25C** : 38.3 V

- **Efficiency** : 17.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WS-280 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WS-280: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED WS-280 stands 1.2 W above the 278.8 W Multi-c-Si median and typical 90.8% PTC-to-STC thermal output (254.2 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,542-$2,523/yr in baseline US bill offset. Lower 38.3 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

## Where Does WAAREE ENERGIES LIMITED WS-280 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WS-280 (280.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WS-280?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WS-280 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WS-280?

Benchmark highlights for WAAREE ENERGIES LIMITED WS-280 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #17,941 / 21,677

### 280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,057

### 17.28% Aperture Efficiency

Power density 172.8 W/m2 (2.63 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.25 V at -10 C (562.2 V string) and 44.66 V at -20 C (13 max).

 8 kW Reference Array

### 29 Panels = 8,120 W STC

Occupies 47.0 m2 (506 sq ft) producing 7,372 W PTC; NEC 690.8 OCPD floor is 14.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.3 * (1 + (-0.369/100) * (-10 - 25)) = 43.25 V | OCPD = 1.56 * 9.35 = 14.59 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WS-280: Voc=38.3 V, beta_Voc=-0.369%/C, Isc=9.35 A, STC=280.0 W, Area=1.62 m2.

**Result:** 13 panels max on 600 V (562.2 V); 29 panels for 8 kW (506 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WS-280?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WS-280 (Multi-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WS-280.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 254.2 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.0 V / 8.75 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.369 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 17.28% (1.62 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WS-280 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WS-280 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.16 kW | 384 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 29 | 8.12 kW | 506 sq ft | $2,032 | $3,437 |
| **10 kW Class** | 36 | 10.08 kW | 628 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WS-280 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WS-280 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **WAAREE ENERGIES LIMITED WS-275** | 275.0 W | 249.5 W | 38.15 V | 31.8 V | 16.98% |
| **WAAREE ENERGIES LIMITED WS-280** | 280.0 W | 254.2 W | 38.3 V | 32.0 V | 17.28% |

## How Many WAAREE ENERGIES LIMITED WS-280 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WS-280 (43.25 V at 14 F).

Computed from Voc=38.3V and beta_Voc=-0.369%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.66 V | 13 panels | 580.6 V | 22 panels |
| **-10 C (14 F)** | 43.25 V | 13 panels | 562.2 V | 23 panels |
| **0 C (32 F)** | 41.83 V | 14 panels | 585.6 V | 23 panels |
| **25 C (77 F STC)** | 38.3 V | 15 panels | 574.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WS-280?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WS-280 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6P-280M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6P-280M**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-280m/) CSI Solar Co Ltd | 280.0 W | Tie (0 W) | 38.5 V | 18.08% | 90.8% |
| [**CSI Solar Co Ltd CS6P-280MX**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6p-280mx/) CSI Solar Co Ltd | 280.0 W | Tie (0 W) | 38.5 V | 18.08% | 90.8% |
| [**GermanSolar USA Inc GSP-280W**](https://epri-peac.com/solar-equipment/modules/germansolar-usa-inc/germansolar-usa-inc-gsp-280w/) GermanSolar USA Inc | 280.0 W | Tie (0 W) | 38.55 V | 16.87% | 92.1% |
| [**Centrosolar America TM6 280xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tm6-280xx/) Centrosolar America | 280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WS-280?

Evaluate WAAREE ENERGIES LIMITED WS-280 (280.0 W STC, 38.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WS-280 reaches 44.66 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 506 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (506 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WS-280 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WS-280 8 kW Residential Fit

Needs 29 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS6P-280M.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 254.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WS-280 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WS-280?

Multiplying WAAREE ENERGIES LIMITED WS-280's 9.35 A short-circuit current by 1.56 equals 14.59 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can WAAREE ENERGIES LIMITED WS-280 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.25 V cold Voc at 14 F and handles 9.35 A Isc; string inverters cap WAAREE ENERGIES LIMITED WS-280 at 13 panels on 600 V.

### Is WAAREE ENERGIES LIMITED WS-280 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WS-280 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, CSI Solar Co Ltd CS6P-280M specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WS-280.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)