title: "WAAREE ENERGIES LIMITED WS-220 Specs (220.0W, 36.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-ws-220/
description: "CEC datasheet for WAAREE ENERGIES LIMITED WS-220: 220.0W STC, 36.0V Voc, 37-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# WAAREE ENERGIES LIMITED WS-220 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED WS-220 is a 220.0 W STC (192.0 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.39% efficiency, 36.0 V Voc at 25 C, and 40.52 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 220.0 W

- **PTC Wattage** : 192.0 W

- **Voc @ 25C** : 36.0 V

- **Efficiency** : 13.39%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED WS-220 Compare Against Peer CEC Listings?

How WAAREE ENERGIES LIMITED WAAREE ENERGIES LIMITED WS-220 handles rooftop heat (192.0 W PTC), 8 kW sizing, and cold winter string voltage.

WAAREE ENERGIES LIMITED builds the WAAREE ENERGIES LIMITED WS-220 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 133.9 W/m2 (6.52 percentage points below 19.91% CEC median). Compared against Alps Technology ATI-M660-220 (220.0 W), this model holds typical 87.3% PTC-to-STC thermal output (192.0 W real-world rating). Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 12.7 A overcurrent floor served by a 15 A breaker.

## Where Does WAAREE ENERGIES LIMITED WS-220 Fall Across Listed CEC Models?

Where WAAREE ENERGIES LIMITED WS-220 (220.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED WS-220?

Percentile placement of WAAREE ENERGIES LIMITED WS-220 across power density (133.9 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WS-220?

Four critical engineering numbers homeowners and solar installers check first when reviewing WAAREE ENERGIES LIMITED WS-220 specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #20,759 / 21,677

### 220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,266

### 13.39% Aperture Efficiency

Power density 133.9 W/m2 (6.52 percentage points below 19.91% CEC median). PTC/STC ratio: 87.3% (rank #21,570).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.52 V at -10 C (567.3 V string) and 41.82 V at -20 C (14 max).

 8 kW Reference Array

### 37 Panels = 8,140 W STC

Occupies 60.8 m2 (654 sq ft) producing 7,104 W PTC; NEC 690.8 OCPD floor is 12.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.359/100) * (-10 - 25)) = 40.52 V | OCPD = 1.56 * 8.14 = 12.7 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WS-220: Voc=36.0 V, beta_Voc=-0.359%/C, Isc=8.14 A, STC=220.0 W, Area=1.643 m2.

**Result:** 14 panels max on 600 V (567.3 V); 37 panels for 8 kW (654 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WS-220?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WAAREE ENERGIES LIMITED WS-220.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WS-220.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 192.0 W (87.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.0 V / 7.6 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.359 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 13.39% (1.643 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many WAAREE ENERGIES LIMITED WS-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WAAREE ENERGIES LIMITED WS-220 (220.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 28 | 6.16 kW | 495 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 37 | 8.14 kW | 654 sq ft | $2,037 | $3,445 |
| **10 kW Class** | 46 | 10.12 kW | 814 sq ft | $2,533 | $4,283 |

## How Many WAAREE ENERGIES LIMITED WS-220 Modules Fit in a Cold-Weather String?

Maximum series module counts for WAAREE ENERGIES LIMITED WS-220 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.0V and beta_Voc=-0.359%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 41.82 V | 14 panels | 585.5 V | 23 panels |
| **-10 C (14 F)** | 40.52 V | 14 panels | 567.3 V | 24 panels |
| **0 C (32 F)** | 39.23 V | 15 panels | 588.4 V | 25 panels |
| **25 C (77 F STC)** | 36.0 V | 16 panels | 576.0 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WS-220?

Alternative CEC solar modules from competing brands near WAAREE ENERGIES LIMITED WS-220 (220.0 W), including Alps Technology ATI-M660-220.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Alps Technology ATI-M660-220**](https://epri-peac.com/solar-equipment/modules/alps-technology/alps-technology-ati-m660-220/) Alps Technology | 220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| [**Anji Technology AJP-M660-220**](https://epri-peac.com/solar-equipment/modules/anji-technology/anji-technology-ajp-m660-220/) Anji Technology | 220.0 W | Tie (0 W) | 36.06 V | 13.55% | 86.0% |
| [**Centrosolar America DP60 220**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp60-220/) Centrosolar America | 220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| [**Anhui Rinengzhongtian Semiconductor Development QJM220-60**](https://epri-peac.com/solar-equipment/modules/anhui-rinengzhongtian-semiconductor-development/anhui-rinengzhongtian-semiconductor-development-qjm220-60/) Anhui Rinengzhongtian Semiconductor Development | 220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WS-220?

Evaluate WAAREE ENERGIES LIMITED WS-220 (220.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WS-220 reaches 41.82 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 654 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (654 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WS-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED WS-220 8 kW Residential Fit

Needs 37 modules (654 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Alps Technology ATI-M660-220.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 192.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WS-220 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WS-220?

Multiplying WAAREE ENERGIES LIMITED WS-220's 8.14 A short-circuit current by 1.56 equals 12.7 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can WAAREE ENERGIES LIMITED WS-220 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.52 V cold Voc at 14 F and handles 8.14 A Isc; string inverters cap WAAREE ENERGIES LIMITED WS-220 at 14 panels on 600 V.

### Is WAAREE ENERGIES LIMITED WS-220 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WS-220 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, Alps Technology ATI-M660-220 specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED WS-220.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)