# WAAREE ENERGIES LIMITED Bi-55-550 — CEC Solar Module Specifications

Manufacturer: [**WAAREE ENERGIES LIMITED**](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) Registry: **CEC Verified Engineering Specification**

WAAREE ENERGIES LIMITED Bi-55-550 is a 550.0 W STC (508.4 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.48% efficiency, 49.91 V Voc at 25 C, and 54.71 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 550.0 W

- **PTC Wattage** : 508.4 W

- **Voc @ 25C** : 49.91 V

- **Efficiency** : 21.48%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does WAAREE ENERGIES LIMITED Bi-55-550 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED Bi-55-550: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from WAAREE ENERGIES LIMITED and peers, WAAREE ENERGIES LIMITED Bi-55-550 stands 140.0 W above the 410.0 W Mono-c-Si median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (11 panels) to 10 kW (19 panels) yields $1,514-$2,616/yr in baseline US bill offset. Higher 49.91 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does WAAREE ENERGIES LIMITED Bi-55-550 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define WAAREE ENERGIES LIMITED Bi-55-550?

Dataset percentiles tracking WAAREE ENERGIES LIMITED Bi-55-550 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED Bi-55-550?

Benchmark highlights for WAAREE ENERGIES LIMITED Bi-55-550 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #2,737 / 21,677

### Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,517

### 21.48% Aperture Efficiency

Power density 214.8 W/m2 (1.57 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.71 V at -10 C (547.1 V string) and 56.09 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,250 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,626 W PTC; NEC 690.8 OCPD floor is 21.78 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.91 * (1 + (-0.275/100) * (-10 - 25)) = 54.71 V | OCPD = 1.56 * 13.96 = 21.78 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED Bi-55-550: Voc=49.91 V, beta_Voc=-0.275%/C, Isc=13.96 A, STC=550.0 W, Area=2.56 m2.

**Result:** 10 panels max on 600 V (547.1 V); 15 panels for 8 kW (413 sq ft).

## What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED Bi-55-550?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED Bi-55-550 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED Bi-55-550.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 508.4 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.91 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.03 V / 13.08 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.275 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.48% (2.56 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many WAAREE ENERGIES LIMITED Bi-55-550 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED Bi-55-550 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.05 kW | 303 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 15 | 8.25 kW | 413 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 19 | 10.45 kW | 524 sq ft | $2,616 | $4,423 |

## How Many WAAREE ENERGIES LIMITED Bi-55-550 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED Bi-55-550 (54.71 V at 14 F).

Computed from Voc=49.91V and beta_Voc=-0.275%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.09 V | 10 panels | 560.9 V | 17 panels |
| **-10 C (14 F)** | 54.71 V | 10 panels | 547.1 V | 18 panels |
| **0 C (32 F)** | 53.34 V | 11 panels | 586.7 V | 18 panels |
| **25 C (77 F STC)** | 49.91 V | 12 panels | 598.9 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED Bi-55-550?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED Bi-55-550 in nameplate wattage and Voc, starting with AMPS Solar AMPS-550P-144BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AMPS Solar AMPS-550P-144BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/) AMPS Solar | 550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| [**Apollo Renewables Inc Apollo-M772BH-550TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m772bh-550tw/) Apollo Renewables Inc | 550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| [**Exiom Solution S A EX550-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144bmh-dg/) Exiom Solution S A | 550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| [**Exiom Solution S A EX550-144M-BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144m-bmh/) Exiom Solution S A | 550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED Bi-55-550?

Evaluate WAAREE ENERGIES LIMITED Bi-55-550 (550.0 W STC, 49.91 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED Bi-55-550 reaches 56.09 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED Bi-55-550 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### WAAREE ENERGIES LIMITED Bi-55-550 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 508.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED Bi-55-550 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED Bi-55-550?

Multiplying WAAREE ENERGIES LIMITED Bi-55-550's 13.96 A short-circuit current by 1.56 equals 21.78 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can WAAREE ENERGIES LIMITED Bi-55-550 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.71 V cold Voc at 14 F and handles 13.96 A Isc; string inverters cap WAAREE ENERGIES LIMITED Bi-55-550 at 10 panels on 600 V.

### Is WAAREE ENERGIES LIMITED Bi-55-550 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED Bi-55-550 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare WAAREE ENERGIES LIMITED equipment, AMPS Solar AMPS-550P-144BB specs, utility payback rates, and NEC string calculators alongside WAAREE ENERGIES LIMITED Bi-55-550.

[All WAAREE ENERGIES LIMITED Certified Solar Models](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From WAAREE ENERGIES LIMITED

- [All WAAREE ENERGIES LIMITED Specs](https://epri-peac.com/solar-equipment/brands/waaree-energies-limited/)
- [WAAREE ENERGIES LIMITED BiN-03-710](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-710/)
- [WAAREE ENERGIES LIMITED BiN-03-690](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-03-690/)
- [WAAREE ENERGIES LIMITED Bi-68-655](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-655/)
- [WAAREE ENERGIES LIMITED Bi-68-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bi-68-635/)
- [WAAREE ENERGIES LIMITED BiN-02-635](https://epri-peac.com/solar-equipment/modules/waaree-energies-limited/waaree-energies-limited-bin-02-635/)