title: "Vikram Solar SOMERA VSMDT7237505 Specs (375.0W, 47.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-somera-vsmdt7237505/
description: "CEC datasheet for Vikram Solar SOMERA VSMDT7237505: 375.0W STC, 47.0V Voc, 22-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Vikram Solar SOMERA VSMDT7237505 — CEC Solar Module Specifications

Manufacturer: [**Vikram Solar**](https://epri-peac.com/solar-equipment/brands/vikram-solar/) Registry: **CEC Verified Engineering Specification**

Vikram Solar SOMERA VSMDT7237505 is a 375.0 W STC (345.9 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 18.56% efficiency, 47.0 V Voc at 25 C, and 51.46 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 375.0 W

- **PTC Wattage** : 345.9 W

- **Voc @ 25C** : 47.0 V

- **Efficiency** : 18.56%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vikram Solar SOMERA VSMDT7237505 Compare Against Peer CEC Listings?

Engineering position of Vikram Solar SOMERA VSMDT7237505 (375.0 W STC) vs. CSI Solar Co Ltd CS3U-380PB-AG across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Vikram Solar SOMERA VSMDT7237505 pairs strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677) with 47.0 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,610 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer CSI Solar Co Ltd CS3U-380PB-AG offers a 380.0 W alternative.

## Where Does Vikram Solar SOMERA VSMDT7237505 Fall Across Listed CEC Models?

Plots Vikram Solar SOMERA VSMDT7237505 at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define Vikram Solar SOMERA VSMDT7237505?

Benchmarks Vikram Solar SOMERA VSMDT7237505 on STC wattage, thermal PTC/STC retention, and 18.56 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMDT7237505?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSMDT7237505 by Vikram Solar.

Rank #11,367 / 21,677

### 375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,241

### 18.56% Aperture Efficiency

Power density 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.46 V at -10 C (566.1 V string) and 52.73 V at -20 C (11 max).

 8 kW Reference Array

### 22 Panels = 8,250 W STC

Occupies 44.4 m2 (478 sq ft) producing 7,610 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.0 * (1 + (-0.271/100) * (-10 - 25)) = 51.46 V | OCPD = 1.56 * 9.99 = 15.58 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMDT7237505: Voc=47.0 V, beta_Voc=-0.271%/C, Isc=9.99 A, STC=375.0 W, Area=2.02 m2.

**Result:** 11 panels max on 600 V (566.1 V); 22 panels for 8 kW (478 sq ft).

## What Are the Published CEC Specifications for Vikram Solar SOMERA VSMDT7237505?

Laboratory test ratings recorded for Vikram Solar SOMERA VSMDT7237505 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMDT7237505.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 345.9 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.1 V / 9.36 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.271 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 18.56% (2.02 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Vikram Solar SOMERA VSMDT7237505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (478 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSMDT7237505.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.0 kW | 348 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 22 | 8.25 kW | 478 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 27 | 10.12 kW | 587 sq ft | $2,533 | $4,283 |

## How Many Vikram Solar SOMERA VSMDT7237505 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Vikram Solar SOMERA VSMDT7237505 (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.0V and beta_Voc=-0.271%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.73 V | 11 panels | 580.0 V | 18 panels |
| **-10 C (14 F)** | 51.46 V | 11 panels | 566.1 V | 19 panels |
| **0 C (32 F)** | 50.18 V | 11 panels | 552.0 V | 19 panels |
| **25 C (77 F STC)** | 47.0 V | 12 panels | 564.0 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMDT7237505?

Closest cross-brand CEC competitors to Vikram Solar SOMERA VSMDT7237505 matched near 375.0 W STC and 47.0 V Voc, led by CSI Solar Co Ltd CS3U-380PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3U-380PB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-380pb-ag/) CSI Solar Co Ltd | 380.0 W | +5.0 W | 47.8 V | 19.29% | 93.5% |
| [**Auxin Solar AXN6M612B380**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m612b380/) Auxin Solar | 380.0 W | +5.0 W | 47.94 V | 19.3% | 93.1% |
| [**CSI Solar Co Ltd CS3U-385MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-385mb-ag/) CSI Solar Co Ltd | 385.0 W | +10.0 W | 48.0 V | 19.85% | 93.9% |
| [**CSI Solar Co Ltd CS3U-360MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-360mb-ag/) CSI Solar Co Ltd | 360.0 W | -15.0 W | 47.0 V | 18.56% | 93.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMDT7237505?

Evaluate Vikram Solar SOMERA VSMDT7237505 (375.0 W STC, 47.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMDT7237505 reaches 52.73 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 478 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (478 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMDT7237505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vikram Solar SOMERA VSMDT7237505 8 kW Residential Fit

Needs 22 modules (478 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-380PB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 345.9 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMDT7237505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Vikram Solar SOMERA VSMDT7237505?

Multiplying Vikram Solar SOMERA VSMDT7237505's 9.99 A short-circuit current by 1.56 equals 15.58 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Vikram Solar SOMERA VSMDT7237505 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.46 V cold Voc at 14 F and handles 9.99 A Isc; string inverters cap Vikram Solar SOMERA VSMDT7237505 at 11 panels on 600 V.

### Is Vikram Solar SOMERA VSMDT7237505 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar SOMERA VSMDT7237505 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare Vikram Solar equipment, CSI Solar Co Ltd CS3U-380PB-AG specs, utility payback rates, and NEC string calculators alongside Vikram Solar SOMERA VSMDT7237505.

[All Vikram Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vikram-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vikram Solar

- [All Vikram Solar Specs](https://epri-peac.com/solar-equipment/brands/vikram-solar/)
- [Vikram Solar PARADEA VSMDH7255505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255505/)
- [Vikram Solar PARADEA VSMDH7255005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255005/)
- [Vikram Solar PARADEA VSMDH7254505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254505/)
- [Vikram Solar PARADEA VSMDH7254005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254005/)
- [Vikram Solar PARADEA VSMDH7253505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7253505/)