# Vikram Solar SOMERA VSMDHT7239005 — CEC Solar Module Specifications

Manufacturer: [**Vikram Solar**](https://epri-peac.com/solar-equipment/brands/vikram-solar/) Registry: **CEC Verified Engineering Specification**

Vikram Solar SOMERA VSMDHT7239005 is a 390.0 W STC (355.2 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 19.31% efficiency, 47.4 V Voc at 25 C, and 51.95 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 355.2 W

- **Voc @ 25C** : 47.4 V

- **Efficiency** : 19.31%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vikram Solar SOMERA VSMDHT7239005 Compare Against Peer CEC Listings?

How Vikram Solar Vikram Solar SOMERA VSMDHT7239005 handles rooftop heat (355.2 W PTC), 8 kW sizing, and cold winter string voltage.

Vikram Solar builds the Vikram Solar SOMERA VSMDHT7239005 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 193.1 W/m2 (0.60 percentage points below 19.91% CEC median). Compared against CSI Solar Co Ltd CS3W-390PB-AG (390.0 W), this model holds typical 91.1% PTC-to-STC thermal output (355.2 W real-world rating). Mid-range 47.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 16.04 A overcurrent floor served by a 20 A breaker.

## Where Does Vikram Solar SOMERA VSMDHT7239005 Fall Across Listed CEC Models?

Where Vikram Solar SOMERA VSMDHT7239005 (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Vikram Solar SOMERA VSMDHT7239005?

Percentile placement of Vikram Solar SOMERA VSMDHT7239005 across power density (193.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMDHT7239005?

Four critical engineering numbers homeowners and solar installers check first when reviewing Vikram Solar SOMERA VSMDHT7239005 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,704

### 19.31% Aperture Efficiency

Power density 193.1 W/m2 (0.60 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.95 V at -10 C (571.5 V string) and 53.24 V at -20 C (11 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 42.4 m2 (457 sq ft) producing 7,459 W PTC; NEC 690.8 OCPD floor is 16.04 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.4 * (1 + (-0.274/100) * (-10 - 25)) = 51.95 V | OCPD = 1.56 * 10.28 = 16.04 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMDHT7239005: Voc=47.4 V, beta_Voc=-0.274%/C, Isc=10.28 A, STC=390.0 W, Area=2.02 m2.

**Result:** 11 panels max on 600 V (571.5 V); 21 panels for 8 kW (457 sq ft).

## What Are the Published CEC Specifications for Vikram Solar SOMERA VSMDHT7239005?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Vikram Solar SOMERA VSMDHT7239005.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMDHT7239005.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 355.2 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 47.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 10.28 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 40.5 V / 9.62 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.274 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.31% (2.02 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Vikram Solar SOMERA VSMDHT7239005 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Vikram Solar SOMERA VSMDHT7239005 (390.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 348 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 457 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 565 sq ft | $2,538 | $4,292 |

## How Many Vikram Solar SOMERA VSMDHT7239005 Modules Fit in a Cold-Weather String?

Maximum series module counts for Vikram Solar SOMERA VSMDHT7239005 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.4V and beta_Voc=-0.274%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 53.24 V | 11 panels | 585.6 V | 18 panels |
| **-10 C (14 F)** | 51.95 V | 11 panels | 571.5 V | 19 panels |
| **0 C (32 F)** | 50.65 V | 11 panels | 557.1 V | 19 panels |
| **25 C (77 F STC)** | 47.4 V | 12 panels | 568.8 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMDHT7239005?

Alternative CEC solar modules from competing brands near Vikram Solar SOMERA VSMDHT7239005 (390.0 W), including CSI Solar Co Ltd CS3W-390PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3W-390PB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3w-390pb-ag/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 46.8 V | 17.97% | 93.3% |
| [**CSI Solar Co Ltd CS3U-385MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3u-385mb-ag/) CSI Solar Co Ltd | 385.0 W | -5.0 W | 48.0 V | 19.85% | 93.9% |
| [**Aptos Solar Technology LLC DNA-144-BF23-395W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bf23-395w/) Aptos Solar Technology LLC | 395.0 W | +5.0 W | 48.26 V | 19.94% | 92.6% |
| [**Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6612m-385l-h-bf/) Boviet Solar Technology Co Ltd | 385.0 W | -5.0 W | 48.45 V | 19.15% | 93.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMDHT7239005?

Evaluate Vikram Solar SOMERA VSMDHT7239005 (390.0 W STC, 47.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMDHT7239005 reaches 53.24 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 457 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (457 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMDHT7239005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vikram Solar SOMERA VSMDHT7239005 8 kW Residential Fit

Needs 21 modules (457 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3W-390PB-AG.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 355.2 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMDHT7239005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Vikram Solar SOMERA VSMDHT7239005?

Multiplying Vikram Solar SOMERA VSMDHT7239005's 10.28 A short-circuit current by 1.56 equals 16.04 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Vikram Solar SOMERA VSMDHT7239005 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.95 V cold Voc at 14 F and handles 10.28 A Isc; string inverters cap Vikram Solar SOMERA VSMDHT7239005 at 11 panels on 600 V.

### Is Vikram Solar SOMERA VSMDHT7239005 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar SOMERA VSMDHT7239005 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

## Related Pages

Compare Vikram Solar equipment, CSI Solar Co Ltd CS3W-390PB-AG specs, utility payback rates, and NEC string calculators alongside Vikram Solar SOMERA VSMDHT7239005.

[All Vikram Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vikram-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vikram Solar

- [All Vikram Solar Specs](https://epri-peac.com/solar-equipment/brands/vikram-solar/)
- [Vikram Solar PARADEA VSMDH7255505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255505/)
- [Vikram Solar PARADEA VSMDH7255005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255005/)
- [Vikram Solar PARADEA VSMDH7254505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254505/)
- [Vikram Solar PARADEA VSMDH7254005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254005/)
- [Vikram Solar PARADEA VSMDH7253505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7253505/)