# Vikram Solar PARADEA VSMDH7255505 — CEC Solar Module Specifications

Manufacturer: [**Vikram Solar**](https://epri-peac.com/solar-equipment/brands/vikram-solar/) Registry: **CEC Verified Engineering Specification**

Vikram Solar PARADEA VSMDH7255505 is a 555.0 W STC (512.3 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 22.2% efficiency, 49.8 V Voc at 25 C, and 54.99 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 555.0 W

- **PTC Wattage** : 512.3 W

- **Voc @ 25C** : 49.8 V

- **Efficiency** : 22.2%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vikram Solar PARADEA VSMDH7255505 Compare Against Peer CEC Listings?

Solar engineering breakdown for Vikram Solar PARADEA VSMDH7255505: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Vikram Solar and peers, Vikram Solar PARADEA VSMDH7255505 stands 145.0 W above the 410.0 W Mono-c-Si median and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Sizing 6 kW (11 panels) to 10 kW (19 panels) yields $1,529-$2,638/yr in baseline US bill offset. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

## Where Does Vikram Solar PARADEA VSMDH7255505 Fall Across Listed CEC Models?

Distribution marker showing Vikram Solar PARADEA VSMDH7255505 (555.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Vikram Solar PARADEA VSMDH7255505?

Dataset percentiles tracking Vikram Solar PARADEA VSMDH7255505 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Vikram Solar PARADEA VSMDH7255505?

Benchmark highlights for Vikram Solar PARADEA VSMDH7255505 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #2,550 / 21,677

### Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,649

### 22.2% Aperture Efficiency

Power density 222.0 W/m2 (2.29 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.99 V at -10 C (549.9 V string) and 56.48 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,325 W STC

Occupies 37.5 m2 (404 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 21.68 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.298/100) * (-10 - 25)) = 54.99 V | OCPD = 1.56 * 13.9 = 21.68 A

Inputs from CEC Modules.csv for Vikram Solar PARADEA VSMDH7255505: Voc=49.8 V, beta_Voc=-0.298%/C, Isc=13.9 A, STC=555.0 W, Area=2.5 m2.

**Result:** 10 panels max on 600 V (549.9 V); 15 panels for 8 kW (404 sq ft).

## What Are the Published CEC Specifications for Vikram Solar PARADEA VSMDH7255505?

Official CEC datasheet figures for Vikram Solar PARADEA VSMDH7255505 (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar PARADEA VSMDH7255505.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 555.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 512.3 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 42.0 V / 13.21 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.298 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.2% (2.5 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Vikram Solar PARADEA VSMDH7255505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Vikram Solar PARADEA VSMDH7255505 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.11 kW | 296 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 15 | 8.32 kW | 404 sq ft | $2,082 | $3,521 |
| **10 kW Class** | 19 | 10.54 kW | 511 sq ft | $2,638 | $4,461 |

## How Many Vikram Solar PARADEA VSMDH7255505 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar PARADEA VSMDH7255505 (54.99 V at 14 F).

Computed from Voc=49.8V and beta_Voc=-0.298%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.48 V | 10 panels | 564.8 V | 17 panels |
| **-10 C (14 F)** | 54.99 V | 10 panels | 549.9 V | 18 panels |
| **0 C (32 F)** | 53.51 V | 11 panels | 588.6 V | 18 panels |
| **25 C (77 F STC)** | 49.8 V | 12 panels | 597.6 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vikram Solar PARADEA VSMDH7255505?

Competing CEC solar panels closest to Vikram Solar PARADEA VSMDH7255505 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6W-555MB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6W-555MB**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-555mb/) CSI Solar Co Ltd | 555.0 W | Tie (0 W) | 49.8 V | 21.94% | 94.2% |
| [**CSI Solar Co Ltd CS6W-555MB-AG**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6w-555mb-ag/) CSI Solar Co Ltd | 555.0 W | Tie (0 W) | 49.8 V | 22.2% | 94.1% |
| [**Aptos Solar Technology LLC DNA-144-BF10-555W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bf10-555w/) Aptos Solar Technology LLC | 555.0 W | Tie (0 W) | 50.0 V | 21.51% | 94.3% |
| [**AXITEC AC-555MBT/144V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-555mbt-144v/) AXITEC | 555.0 W | Tie (0 W) | 50.05 V | 21.68% | 93.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vikram Solar PARADEA VSMDH7255505?

Evaluate Vikram Solar PARADEA VSMDH7255505 (555.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar PARADEA VSMDH7255505 reaches 56.48 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Vikram Solar PARADEA VSMDH7255505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vikram Solar PARADEA VSMDH7255505 8 kW Residential Fit

Needs 15 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS6W-555MB.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 512.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar PARADEA VSMDH7255505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Vikram Solar PARADEA VSMDH7255505?

Multiplying Vikram Solar PARADEA VSMDH7255505's 13.9 A short-circuit current by 1.56 equals 21.68 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Vikram Solar PARADEA VSMDH7255505 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.99 V cold Voc at 14 F and handles 13.9 A Isc; string inverters cap Vikram Solar PARADEA VSMDH7255505 at 10 panels on 600 V.

### Is Vikram Solar PARADEA VSMDH7255505 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar PARADEA VSMDH7255505 rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.

## Related Pages

Compare Vikram Solar equipment, CSI Solar Co Ltd CS6W-555MB specs, utility payback rates, and NEC string calculators alongside Vikram Solar PARADEA VSMDH7255505.

[All Vikram Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vikram-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vikram Solar

- [All Vikram Solar Specs](https://epri-peac.com/solar-equipment/brands/vikram-solar/)
- [Vikram Solar PARADEA VSMDH7255005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255005/)
- [Vikram Solar PARADEA VSMDH7254505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254505/)
- [Vikram Solar PARADEA VSMDH7254005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254005/)
- [Vikram Solar PARADEA VSMDH7253505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7253505/)
- [Vikram Solar PREXOS VSMDHT7848505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-prexos-vsmdht7848505/)