# Vikram Solar PARADEA VSMDH7255005 — CEC Solar Module Specifications

Manufacturer: [**Vikram Solar**](https://epri-peac.com/solar-equipment/brands/vikram-solar/) Registry: **CEC Verified Engineering Specification**

Vikram Solar PARADEA VSMDH7255005 is a 550.0 W STC (507.5 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 22.0% efficiency, 49.7 V Voc at 25 C, and 54.88 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 550.0 W

- **PTC Wattage** : 507.5 W

- **Voc @ 25C** : 49.7 V

- **Efficiency** : 22.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vikram Solar PARADEA VSMDH7255005 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Vikram Solar PARADEA VSMDH7255005 (Mono-c-Si) residential solar systems.

Homeowners evaluating Vikram Solar PARADEA VSMDH7255005 need 11 panels for 6 kW or 15 panels (404 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.298%/C) pushes open-circuit voltage to 54.88 V at 14 F and 56.36 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

## Where Does Vikram Solar PARADEA VSMDH7255005 Fall Across Listed CEC Models?

Comparison of Vikram Solar PARADEA VSMDH7255005 (550.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define Vikram Solar PARADEA VSMDH7255005?

Relative ranking of Vikram Solar PARADEA VSMDH7255005 across nameplate watts, 92.3% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for Vikram Solar PARADEA VSMDH7255005?

Summary of Vikram Solar PARADEA VSMDH7255005 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,737 / 21,677

### Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,124

### 22.0% Aperture Efficiency

Power density 220.0 W/m2 (2.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.88 V at -10 C (548.8 V string) and 56.36 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,250 W STC

Occupies 37.5 m2 (404 sq ft) producing 7,612 W PTC; NEC 690.8 OCPD floor is 21.54 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.7 * (1 + (-0.298/100) * (-10 - 25)) = 54.88 V | OCPD = 1.56 * 13.81 = 21.54 A

Inputs from CEC Modules.csv for Vikram Solar PARADEA VSMDH7255005: Voc=49.7 V, beta_Voc=-0.298%/C, Isc=13.81 A, STC=550.0 W, Area=2.5 m2.

**Result:** 10 panels max on 600 V (548.8 V); 15 panels for 8 kW (404 sq ft).

## What Are the Published CEC Specifications for Vikram Solar PARADEA VSMDH7255005?

Complete CEC test sheet for Vikram Solar PARADEA VSMDH7255005 including Isc (13.81 A), Voc (49.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar PARADEA VSMDH7255005.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 507.5 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.81 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.9 V / 13.12 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.298 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.0% (2.5 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Vikram Solar PARADEA VSMDH7255005 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Vikram Solar PARADEA VSMDH7255005.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.05 kW | 296 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 15 | 8.25 kW | 404 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 19 | 10.45 kW | 511 sq ft | $2,616 | $4,423 |

## How Many Vikram Solar PARADEA VSMDH7255005 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Vikram Solar PARADEA VSMDH7255005 (49.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.7V and beta_Voc=-0.298%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.36 V | 10 panels | 563.6 V | 17 panels |
| **-10 C (14 F)** | 54.88 V | 10 panels | 548.8 V | 18 panels |
| **0 C (32 F)** | 53.4 V | 11 panels | 587.4 V | 18 panels |
| **25 C (77 F STC)** | 49.7 V | 12 panels | 596.4 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vikram Solar PARADEA VSMDH7255005?

Four comparable CEC modules such as AMPS Solar AMPS-550P-144BB (550.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**AMPS Solar AMPS-550P-144BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-550p-144bb/) AMPS Solar | 550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| [**Apollo Renewables Inc Apollo-M772BH-550TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m772bh-550tw/) Apollo Renewables Inc | 550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| [**Exiom Solution S A EX550-144BMH-DG**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144bmh-dg/) Exiom Solution S A | 550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| [**Exiom Solution S A EX550-144M-BMH**](https://epri-peac.com/solar-equipment/modules/exiom-solution-s-a/exiom-solution-s-a-ex550-144m-bmh/) Exiom Solution S A | 550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vikram Solar PARADEA VSMDH7255005?

Evaluate Vikram Solar PARADEA VSMDH7255005 (550.0 W STC, 49.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar PARADEA VSMDH7255005 reaches 56.36 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Vikram Solar PARADEA VSMDH7255005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vikram Solar PARADEA VSMDH7255005 8 kW Residential Fit

Needs 15 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 507.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar PARADEA VSMDH7255005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Vikram Solar PARADEA VSMDH7255005 PTC wattage (507.5 W) lower than STC (550.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 507.5 W PTC (92.3% retention) across Vikram Solar PARADEA VSMDH7255005's 2.5 m2 aperture.

### Who should skip Vikram Solar PARADEA VSMDH7255005 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Vikram Solar PARADEA VSMDH7255005 panels (404 sq ft) leave unusable roof gaps vs. AMPS Solar AMPS-550P-144BB.

### What is the 1,000 V commercial string limit for Vikram Solar PARADEA VSMDH7255005?

On 1,000 V commercial inverters at -10 C (54.88 V cold Voc), Vikram Solar PARADEA VSMDH7255005 fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Vikram Solar PARADEA VSMDH7255005.

## Related Pages

Compare Vikram Solar equipment, AMPS Solar AMPS-550P-144BB specs, utility payback rates, and NEC string calculators alongside Vikram Solar PARADEA VSMDH7255005.

[All Vikram Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vikram-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vikram Solar

- [All Vikram Solar Specs](https://epri-peac.com/solar-equipment/brands/vikram-solar/)
- [Vikram Solar PARADEA VSMDH7255505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255505/)
- [Vikram Solar PARADEA VSMDH7254505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254505/)
- [Vikram Solar PARADEA VSMDH7254005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254005/)
- [Vikram Solar PARADEA VSMDH7253505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7253505/)
- [Vikram Solar PREXOS VSMDHT7848505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-prexos-vsmdht7848505/)