Manufacturer: [**Vikram Solar**](https://epri-peac.com/solar-equipment/brands/vikram-solar/) Registry: **CEC Verified Engineering Specification**

Vikram Solar PARADEA VSMDH7254005 is a 540.0 W STC (497.7 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.18% efficiency, 49.5 V Voc at 25 C, and 54.66 V cold Voc at -10 C (10 panels max per 600 V string).

- **STC Wattage** : 540.0 W

- **PTC Wattage** : 497.7 W

- **Voc @ 25C** : 49.5 V

- **Efficiency** : 21.18%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vikram Solar PARADEA VSMDH7254005 Compare Against Peer CEC Listings?

How Vikram Solar Vikram Solar PARADEA VSMDH7254005 handles rooftop heat (497.7 W PTC), 8 kW sizing, and cold winter string voltage.

Vikram Solar builds the Vikram Solar PARADEA VSMDH7254005 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 211.8 W/m2 (1.27 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-144-BF10-540W (540.0 W), this model holds strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Higher 49.5 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 21.28 A overcurrent floor served by a 25 A breaker.

## Where Does Vikram Solar PARADEA VSMDH7254005 Fall Across Listed CEC Models?

Where Vikram Solar PARADEA VSMDH7254005 (540.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Vikram Solar PARADEA VSMDH7254005?

Percentile placement of Vikram Solar PARADEA VSMDH7254005 across power density (211.8 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Vikram Solar PARADEA VSMDH7254005?

Four critical engineering numbers homeowners and solar installers check first when reviewing Vikram Solar PARADEA VSMDH7254005 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #3,265 / 21,677

### Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,646

### 21.18% Aperture Efficiency

Power density 211.8 W/m2 (1.27 percentage points above 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

### 10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.66 V at -10 C (546.6 V string) and 56.14 V at -20 C (10 max).

 8 kW Reference Array

### 15 Panels = 8,100 W STC

Occupies 38.2 m2 (412 sq ft) producing 7,466 W PTC; NEC 690.8 OCPD floor is 21.28 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.5 * (1 + (-0.298/100) * (-10 - 25)) = 54.66 V | OCPD = 1.56 * 13.64 = 21.28 A

Inputs from CEC Modules.csv for Vikram Solar PARADEA VSMDH7254005: Voc=49.5 V, beta_Voc=-0.298%/C, Isc=13.64 A, STC=540.0 W, Area=2.55 m2.

**Result:** 10 panels max on 600 V (546.6 V); 15 panels for 8 kW (412 sq ft).

## What Are the Published CEC Specifications for Vikram Solar PARADEA VSMDH7254005?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Vikram Solar PARADEA VSMDH7254005.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar PARADEA VSMDH7254005.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 497.7 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 49.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 41.7 V / 12.95 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.298 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.18% (2.55 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Vikram Solar PARADEA VSMDH7254005 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Vikram Solar PARADEA VSMDH7254005 (540.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.48 kW | 329 sq ft | $1,622 | $2,742 |
| **8 kW Class** | 15 | 8.1 kW | 412 sq ft | $2,027 | $3,428 |
| **10 kW Class** | 19 | 10.26 kW | 522 sq ft | $2,568 | $4,342 |

## How Many Vikram Solar PARADEA VSMDH7254005 Modules Fit in a Cold-Weather String?

Maximum series module counts for Vikram Solar PARADEA VSMDH7254005 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.5V and beta_Voc=-0.298%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 56.14 V | 10 panels | 561.4 V | 17 panels |
| **-10 C (14 F)** | 54.66 V | 10 panels | 546.6 V | 18 panels |
| **0 C (32 F)** | 53.19 V | 11 panels | 585.1 V | 18 panels |
| **25 C (77 F STC)** | 49.5 V | 12 panels | 594.0 V | 20 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vikram Solar PARADEA VSMDH7254005?

Alternative CEC solar modules from competing brands near Vikram Solar PARADEA VSMDH7254005 (540.0 W), including Aptos Solar Technology LLC DNA-144-BF10-540W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-144-BF10-540W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-144-bf10-540w/) Aptos Solar Technology LLC | 540.0 W | Tie (0 W) | 49.5 V | 20.93% | 94.2% |
| [**Elin Energy (Sirius PV) ELNSM72M-HC-BF-540**](https://epri-peac.com/solar-equipment/modules/elin-energy-sirius-pv/elin-energy-sirius-pv-elnsm72m-hc-bf-540/) Elin Energy (Sirius PV) | 540.0 W | Tie (0 W) | 49.5 V | 21.09% | 94.4% |
| [**EMMVEE Photovoltaic Power Private Limited E540HCBG144**](https://epri-peac.com/solar-equipment/modules/emmvee-photovoltaic-power-private-limited/emmvee-photovoltaic-power-private-limited-e540hcbg144/) EMMVEE Photovoltaic Power Private Limited | 540.0 W | Tie (0 W) | 49.5 V | 21.09% | 93.3% |
| [**Apollo Renewables Inc Apollo-M772BH-540TW**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m772bh-540tw/) Apollo Renewables Inc | 540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vikram Solar PARADEA VSMDH7254005?

Evaluate Vikram Solar PARADEA VSMDH7254005 (540.0 W STC, 49.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar PARADEA VSMDH7254005 reaches 56.14 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 412 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Vikram Solar PARADEA VSMDH7254005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vikram Solar PARADEA VSMDH7254005 8 kW Residential Fit

Needs 15 modules (412 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF10-540W.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 497.7 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar PARADEA VSMDH7254005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Vikram Solar PARADEA VSMDH7254005?

Multiplying Vikram Solar PARADEA VSMDH7254005's 13.64 A short-circuit current by 1.56 equals 21.28 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Vikram Solar PARADEA VSMDH7254005 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.66 V cold Voc at 14 F and handles 13.64 A Isc; string inverters cap Vikram Solar PARADEA VSMDH7254005 at 10 panels on 600 V.

### Is Vikram Solar PARADEA VSMDH7254005 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar PARADEA VSMDH7254005 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

## Related Pages

Compare Vikram Solar equipment, Aptos Solar Technology LLC DNA-144-BF10-540W specs, utility payback rates, and NEC string calculators alongside Vikram Solar PARADEA VSMDH7254005.

[All Vikram Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vikram-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vikram Solar

- [All Vikram Solar Specs](https://epri-peac.com/solar-equipment/brands/vikram-solar/)
- [Vikram Solar PARADEA VSMDH7255505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255505/)
- [Vikram Solar PARADEA VSMDH7255005](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7255005/)
- [Vikram Solar PARADEA VSMDH7254505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7254505/)
- [Vikram Solar PARADEA VSMDH7253505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-paradea-vsmdh7253505/)
- [Vikram Solar PREXOS VSMDHT7848505](https://epri-peac.com/solar-equipment/modules/vikram-solar/vikram-solar-prexos-vsmdht7848505/)