title: "Vietnam Sunergy Joint Stock Specs (505.0W, 45.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun505-132bmh/
description: "CEC datasheet for Vietnam Sunergy Joint Stock Company VSUN505-132BMH: 505.0W STC, 45.6V Voc, 16-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# Vietnam Sunergy Joint Stock Company VSUN505-132BMH — CEC Solar Module Specifications

Manufacturer: [**Vietnam Sunergy Joint Stock Company**](https://epri-peac.com/solar-equipment/brands/vietnam-sunergy-joint-stock-company/) Registry: **CEC Verified Engineering Specification**

Vietnam Sunergy Joint Stock Company VSUN505-132BMH is a 505.0 W STC (473.8 W PTC) Mono-c-Si solar module ranking #4,444 of 21,677 CEC listings (top 20.8%; higher than 79.2% of peers). It delivers 21.31% efficiency, 45.6 V Voc at 25 C, and 49.69 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 505.0 W

- **PTC Wattage** : 473.8 W

- **Voc @ 25C** : 45.6 V

- **Efficiency** : 21.31%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vietnam Sunergy Joint Stock Company VSUN505-132BMH Compare Against Peer CEC Listings?

How Vietnam Sunergy Joint Stock Company Vietnam Sunergy Joint Stock Company VSUN505-132BMH handles rooftop heat (473.8 W PTC), 8 kW sizing, and cold winter string voltage.

Vietnam Sunergy Joint Stock Company builds the Vietnam Sunergy Joint Stock Company VSUN505-132BMH (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 213.1 W/m2 (1.40 percentage points above 19.91% CEC median). Compared against Hyperion Solar HY-DH132P8-505 (505.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Mid-range 45.6 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.84 A overcurrent floor served by a 25 A breaker.

## Where Does Vietnam Sunergy Joint Stock Company VSUN505-132BMH Fall Across Listed CEC Models?

Where Vietnam Sunergy Joint Stock Company VSUN505-132BMH (505.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Vietnam Sunergy Joint Stock Company VSUN505-132BMH?

Percentile placement of Vietnam Sunergy Joint Stock Company VSUN505-132BMH across power density (213.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Vietnam Sunergy Joint Stock Company VSUN505-132BMH?

Four critical engineering numbers homeowners and solar installers check first when reviewing Vietnam Sunergy Joint Stock Company VSUN505-132BMH specifications.

Rank #4,444 / 21,677

### Top 20.8% STC Output

505.0 W STC (+120.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,088

### 21.31% Aperture Efficiency

Power density 213.1 W/m2 (1.40 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.69 V at -10 C (596.3 V string) and 50.85 V at -20 C (11 max).

 8 kW Reference Array

### 16 Panels = 8,080 W STC

Occupies 37.9 m2 (408 sq ft) producing 7,581 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.6 * (1 + (-0.256/100) * (-10 - 25)) = 49.69 V | OCPD = 1.56 * 14.0 = 21.84 A

Inputs from CEC Modules.csv for Vietnam Sunergy Joint Stock Company VSUN505-132BMH: Voc=45.6 V, beta_Voc=-0.256%/C, Isc=14.0 A, STC=505.0 W, Area=2.37 m2.

**Result:** 12 panels max on 600 V (596.3 V); 16 panels for 8 kW (408 sq ft).

## What Are the Published CEC Specifications for Vietnam Sunergy Joint Stock Company VSUN505-132BMH?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Vietnam Sunergy Joint Stock Company VSUN505-132BMH.

Official California Energy Commission (NREL SAM) test parameters for Vietnam Sunergy Joint Stock Company VSUN505-132BMH.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 505.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 473.8 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 38.6 V / 13.09 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.256 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.31% (2.37 m2) | Array roof footprint density |
| **Cell Count & Technology** | 66 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many Vietnam Sunergy Joint Stock Company VSUN505-132BMH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Vietnam Sunergy Joint Stock Company VSUN505-132BMH (505.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 12 | 6.06 kW | 306 sq ft | $1,517 | $2,565 |
| **8 kW Class** | 16 | 8.08 kW | 408 sq ft | $2,022 | $3,420 |
| **10 kW Class** | 20 | 10.1 kW | 510 sq ft | $2,528 | $4,275 |

## Which Sibling Wattage & Trim Variants Belong to This Vietnam Sunergy Joint Stock Company Series?

All closely matched Vietnam Sunergy Joint Stock Company wattages and cosmetic trims sharing the Vietnam Sunergy Joint Stock Company VSUN505-132BMH architecture.

Sibling CEC listings grouped into the Vietnam Sunergy Joint Stock Company VSUN505-132BMH wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Vietnam Sunergy Joint Stock Company VSUN500-132BMH** | 500.0 W | 469.0 W | 45.4 V | 38.4 V | 21.1% |
| **Vietnam Sunergy Joint Stock Company VSUN505-132BMH** | 505.0 W | 473.8 W | 45.6 V | 38.6 V | 21.31% |
| **Vietnam Sunergy Joint Stock Company VSUN510-132BMH** | 510.0 W | 478.6 W | 45.76 V | 38.77 V | 21.52% |

## How Many Vietnam Sunergy Joint Stock Company VSUN505-132BMH Modules Fit in a Cold-Weather String?

Maximum series module counts for Vietnam Sunergy Joint Stock Company VSUN505-132BMH from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.6V and beta_Voc=-0.256%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 50.85 V | 11 panels | 559.4 V | 19 panels |
| **-10 C (14 F)** | 49.69 V | 12 panels | 596.3 V | 20 panels |
| **0 C (32 F)** | 48.52 V | 12 panels | 582.2 V | 20 panels |
| **25 C (77 F STC)** | 45.6 V | 13 panels | 592.8 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vietnam Sunergy Joint Stock Company VSUN505-132BMH?

Alternative CEC solar modules from competing brands near Vietnam Sunergy Joint Stock Company VSUN505-132BMH (505.0 W), including Hyperion Solar HY-DH132P8-505.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hyperion Solar HY-DH132P8-505**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-505/) Hyperion Solar | 505.0 W | Tie (0 W) | 45.72 V | 21.31% | 93.0% |
| [**Hyperion Solar HY-DH132P8-505-B**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-505-b/) Hyperion Solar | 505.0 W | Tie (0 W) | 45.72 V | 21.31% | 93.0% |
| [**Hyperion Solar HY-DH132P8-505-T**](https://epri-peac.com/solar-equipment/modules/hyperion-solar/hyperion-solar-hy-dh132p8-505-t/) Hyperion Solar | 505.0 W | Tie (0 W) | 45.72 V | 21.31% | 93.0% |
| [**Aptos Solar Technology LLC DNA-132-BF10-500W**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-132-bf10-500w/) Aptos Solar Technology LLC | 500.0 W | -5.0 W | 45.6 V | 21.1% | 94.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vietnam Sunergy Joint Stock Company VSUN505-132BMH?

Evaluate Vietnam Sunergy Joint Stock Company VSUN505-132BMH (505.0 W STC, 45.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vietnam Sunergy Joint Stock Company VSUN505-132BMH reaches 50.85 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 16 panels for an 8 kW build require 408 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 16 panels (408 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vietnam Sunergy Joint Stock Company VSUN505-132BMH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vietnam Sunergy Joint Stock Company VSUN505-132BMH 8 kW Residential Fit

Needs 16 modules (408 sq ft) with a 25 A string OCPD, offsetting ~$2,022/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Hyperion Solar HY-DH132P8-505.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 473.8 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vietnam Sunergy Joint Stock Company VSUN505-132BMH by Vietnam Sunergy Joint Stock Company grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Vietnam Sunergy Joint Stock Company VSUN505-132BMH?

Multiplying Vietnam Sunergy Joint Stock Company VSUN505-132BMH's 14.0 A short-circuit current by 1.56 equals 21.84 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Vietnam Sunergy Joint Stock Company VSUN505-132BMH pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.69 V cold Voc at 14 F and handles 14.0 A Isc; string inverters cap Vietnam Sunergy Joint Stock Company VSUN505-132BMH at 12 panels on 600 V.

### Is Vietnam Sunergy Joint Stock Company VSUN505-132BMH eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vietnam Sunergy Joint Stock Company VSUN505-132BMH rely on utility bill offset (~$2,022/yr at 8 kW) rather than 25D.

## Related Pages

Compare Vietnam Sunergy Joint Stock Company equipment, Hyperion Solar HY-DH132P8-505 specs, utility payback rates, and NEC string calculators alongside Vietnam Sunergy Joint Stock Company VSUN505-132BMH.

[All Vietnam Sunergy Joint Stock Company Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vietnam-sunergy-joint-stock-company/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vietnam Sunergy Joint Stock Company

- [All Vietnam Sunergy Joint Stock Company Specs](https://epri-peac.com/solar-equipment/brands/vietnam-sunergy-joint-stock-company/)
- [Vietnam Sunergy Joint Stock Company VSUN710N-132BMH-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun710n-132bmh-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN690N-132BMH-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun690n-132bmh-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN635N-156BMH-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun635n-156bmh-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN630N-132BMHR-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun630n-132bmhr-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN615N-132BMHR-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun615n-132bmhr-dg/)