# Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW — CEC Solar Module Specifications

Manufacturer: [**Vietnam Sunergy Joint Stock Company**](https://epri-peac.com/solar-equipment/brands/vietnam-sunergy-joint-stock-company/) Registry: **CEC Verified Engineering Specification**

Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW is a 485.0 W STC (453.0 W PTC) Mono-c-Si solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 22.45% efficiency, 43.3 V Voc at 25 C, and 47.5 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 485.0 W

- **PTC Wattage** : 453.0 W

- **Voc @ 25C** : 43.3 V

- **Efficiency** : 22.45%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW Compare Against Peer CEC Listings?

Solar engineering breakdown for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Vietnam Sunergy Joint Stock Company and peers, Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW stands 75.0 W above the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (13 panels) to 10 kW (21 panels) yields $1,577-$2,550/yr in baseline US bill offset. Mid-range 43.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

## Where Does Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW Fall Across Listed CEC Models?

Distribution marker showing Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW (485.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW?

Dataset percentiles tracking Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW?

Benchmark highlights for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,730 / 21,677

### Top 22.2% STC Output

485.0 W STC (+100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,153

### 22.45% Aperture Efficiency

Power density 224.5 W/m2 (2.54 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.5 V at -10 C (570.0 V string) and 48.7 V at -20 C (12 max).

 8 kW Reference Array

### 17 Panels = 8,245 W STC

Occupies 36.7 m2 (395 sq ft) producing 7,701 W PTC; NEC 690.8 OCPD floor is 21.65 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.3 * (1 + (-0.277/100) * (-10 - 25)) = 47.5 V | OCPD = 1.56 * 13.88 = 21.65 A

Inputs from CEC Modules.csv for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW: Voc=43.3 V, beta_Voc=-0.277%/C, Isc=13.88 A, STC=485.0 W, Area=2.16 m2.

**Result:** 12 panels max on 600 V (570.0 V); 17 panels for 8 kW (395 sq ft).

## What Are the Published CEC Specifications for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW?

Official CEC datasheet figures for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 453.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.72 V / 13.21 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.277 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.45% (2.16 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.3 kW | 302 sq ft | $1,577 | $2,666 |
| **8 kW Class** | 17 | 8.24 kW | 395 sq ft | $2,062 | $3,487 |
| **10 kW Class** | 21 | 10.19 kW | 488 sq ft | $2,550 | $4,313 |

## Which Sibling Wattage & Trim Variants Belong to This Vietnam Sunergy Joint Stock Company Series?

Consolidated Vietnam Sunergy Joint Stock Company wattage variants sharing the Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW mechanical and cell layout.

Sibling CEC listings grouped into the Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Vietnam Sunergy Joint Stock Company VSUN475N-120MH-BW** | 475.0 W | 443.4 W | 42.78 V | 36.24 V | 21.99% |
| **Vietnam Sunergy Joint Stock Company VSUN480N-120MH-BW** | 480.0 W | 448.2 W | 43.05 V | 36.49 V | 22.22% |
| **Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW** | 485.0 W | 453.0 W | 43.3 V | 36.72 V | 22.45% |
| **Vietnam Sunergy Joint Stock Company VSUN490N-120MH-BW** | 490.0 W | 457.8 W | 43.54 V | 36.94 V | 22.69% |

## How Many Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW (47.5 V at 14 F).

Computed from Voc=43.3V and beta_Voc=-0.277%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 48.7 V | 12 panels | 584.4 V | 20 panels |
| **-10 C (14 F)** | 47.5 V | 12 panels | 570.0 V | 21 panels |
| **0 C (32 F)** | 46.3 V | 12 panels | 555.6 V | 21 panels |
| **25 C (77 F STC)** | 43.3 V | 13 panels | 562.9 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW?

Competing CEC solar panels closest to Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW in nameplate wattage and Voc, starting with Hanersun Energy Co Ltd HN18N-60HT485W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Hanersun Energy Co Ltd HN18N-60HT485W**](https://epri-peac.com/solar-equipment/modules/hanersun-energy-co-ltd/hanersun-energy-co-ltd-hn18n-60ht485w/) Hanersun Energy Co Ltd | 485.0 W | Tie (0 W) | 43.0 V | 22.99% | 94.9% |
| [**Auxin Solar AXN10M485B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485b/) Auxin Solar | 485.0 W | Tie (0 W) | 43.98 V | 22.56% | 92.0% |
| [**Auxin Solar AXN10M485W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m485w/) Auxin Solar | 485.0 W | Tie (0 W) | 43.98 V | 22.56% | 91.8% |
| [**CSI Solar Co Ltd CS61-60TM-485H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-60tm-485h/) CSI Solar Co Ltd | 485.0 W | Tie (0 W) | 42.6 V | 22.15% | 94.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW?

Evaluate Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW (485.0 W STC, 43.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW reaches 48.7 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 395 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (395 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW 8 kW Residential Fit

Needs 17 modules (395 sq ft) with a 25 A string OCPD, offsetting ~$2,062/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Hanersun Energy Co Ltd HN18N-60HT485W.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 453.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW by Vietnam Sunergy Joint Stock Company grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW?

Multiplying Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW's 13.88 A short-circuit current by 1.56 equals 21.65 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.5 V cold Voc at 14 F and handles 13.88 A Isc; string inverters cap Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW at 12 panels on 600 V.

### Is Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW rely on utility bill offset (~$2,062/yr at 8 kW) rather than 25D.

## Related Pages

Compare Vietnam Sunergy Joint Stock Company equipment, Hanersun Energy Co Ltd HN18N-60HT485W specs, utility payback rates, and NEC string calculators alongside Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW.

[All Vietnam Sunergy Joint Stock Company Certified Solar Models](https://epri-peac.com/solar-equipment/brands/vietnam-sunergy-joint-stock-company/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Vietnam Sunergy Joint Stock Company

- [All Vietnam Sunergy Joint Stock Company Specs](https://epri-peac.com/solar-equipment/brands/vietnam-sunergy-joint-stock-company/)
- [Vietnam Sunergy Joint Stock Company VSUN710N-132BMH-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun710n-132bmh-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN690N-132BMH-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun690n-132bmh-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN635N-156BMH-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun635n-156bmh-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN630N-132BMHR-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun630n-132bmhr-dg/)
- [Vietnam Sunergy Joint Stock Company VSUN615N-132BMHR-DG](https://epri-peac.com/solar-equipment/modules/vietnam-sunergy-joint-stock-company/vietnam-sunergy-joint-stock-company-vsun615n-132bmhr-dg/)