title: "Venus Energy Limited VE-590-60IIMK Specs (590.0W, 41.45V Voc)"
url: https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-590-60iimk/
description: "CEC datasheet for Venus Energy Limited VE-590-60IIMK: 590.0W STC, 41.45V Voc, 14-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Venus Energy Limited VE-590-60IIMK — CEC Solar Module Specifications

Manufacturer: [**Venus Energy Limited**](https://epri-peac.com/solar-equipment/brands/venus-energy-limited/) Registry: **CEC Verified Engineering Specification**

Venus Energy Limited VE-590-60IIMK is a 590.0 W STC (553.6 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 20.77% efficiency, 41.45 V Voc at 25 C, and 45.18 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 590.0 W

- **PTC Wattage** : 553.6 W

- **Voc @ 25C** : 41.45 V

- **Efficiency** : 20.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Venus Energy Limited VE-590-60IIMK Compare Against Peer CEC Listings?

How Venus Energy Limited Venus Energy Limited VE-590-60IIMK handles rooftop heat (553.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Venus Energy Limited VE-590-60IIMK exhibits 17.93 A short-circuit current, requiring a 27.97 A (156%) conductor rating and 30 A OCPD under NEC 690.8. Ranked #1,597 of 21,677 (180.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 39.8 m2 for an 8 kW system (17 panels for 10 kW). Mid-range 41.45 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

## Where Does Venus Energy Limited VE-590-60IIMK Fall Across Listed CEC Models?

Where Venus Energy Limited VE-590-60IIMK (590.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Venus Energy Limited VE-590-60IIMK?

Percentile placement of Venus Energy Limited VE-590-60IIMK across power density (207.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Venus Energy Limited VE-590-60IIMK?

Four critical engineering numbers homeowners and solar installers check first when reviewing Venus Energy Limited VE-590-60IIMK specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #1,597 / 21,677

### Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,352

### 20.77% Aperture Efficiency

Power density 207.7 W/m2 (0.86 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.18 V at -10 C (587.3 V string) and 46.24 V at -20 C (12 max).

 8 kW Reference Array

### 14 Panels = 8,260 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,750 W PTC; NEC 690.8 OCPD floor is 27.97 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.45 * (1 + (-0.257/100) * (-10 - 25)) = 45.18 V | OCPD = 1.56 * 17.93 = 27.97 A

Inputs from CEC Modules.csv for Venus Energy Limited VE-590-60IIMK: Voc=41.45 V, beta_Voc=-0.257%/C, Isc=17.93 A, STC=590.0 W, Area=2.84 m2.

**Result:** 13 panels max on 600 V (587.3 V); 14 panels for 8 kW (428 sq ft).

## What Are the Published CEC Specifications for Venus Energy Limited VE-590-60IIMK?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Venus Energy Limited VE-590-60IIMK.

Official California Energy Commission (NREL SAM) test parameters for Venus Energy Limited VE-590-60IIMK.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 590.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 553.6 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 41.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 17.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 34.55 V / 17.08 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.257 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.77% (2.84 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Venus Energy Limited VE-590-60IIMK Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Venus Energy Limited VE-590-60IIMK (590.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 11 | 6.49 kW | 336 sq ft | $1,624 | $2,747 |
| **8 kW Class** | 14 | 8.26 kW | 428 sq ft | $2,067 | $3,496 |
| **10 kW Class** | 17 | 10.03 kW | 520 sq ft | $2,510 | $4,245 |

## Which Sibling Wattage & Trim Variants Belong to This Venus Energy Limited Series?

All closely matched Venus Energy Limited wattages and cosmetic trims sharing the Venus Energy Limited VE-590-60IIMK architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Venus Energy Limited VE-590-60IIMK wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Venus Energy Limited VE-575-60IIMK** | 575.0 W | 539.2 W | 40.93 V | 34.11 V | 20.25% |
| **Venus Energy Limited VE-580-60IIMK** | 580.0 W | 544.0 W | 41.11 V | 34.26 V | 20.42% |
| **Venus Energy Limited VE-590-60IIMK** | 590.0 W | 553.6 W | 41.45 V | 34.55 V | 20.77% |
| **Venus Energy Limited VE-595-60IIMK** | 595.0 W | 558.4 W | 41.63 V | 34.69 V | 20.95% |

## How Many Venus Energy Limited VE-590-60IIMK Modules Fit in a Cold-Weather String?

Maximum series module counts for Venus Energy Limited VE-590-60IIMK from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.45V and beta_Voc=-0.257%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 46.24 V | 12 panels | 554.9 V | 21 panels |
| **-10 C (14 F)** | 45.18 V | 13 panels | 587.3 V | 22 panels |
| **0 C (32 F)** | 44.11 V | 13 panels | 573.4 V | 22 panels |
| **25 C (77 F STC)** | 41.45 V | 14 panels | 580.3 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Venus Energy Limited VE-590-60IIMK?

Alternative CEC solar modules from competing brands near Venus Energy Limited VE-590-60IIMK (590.0 W), including G-Star Pte Ltd GSD8J60M-595BT.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**G-Star Pte Ltd GSD8J60M-595BT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd8j60m-595bt/) G-Star Pte Ltd | 595.0 W | +5.0 W | 41.4 V | 21.17% | 94.2% |
| [**G-Star Pte Ltd GSD8J60M-595WT**](https://epri-peac.com/solar-equipment/modules/g-star-pte-ltd/g-star-pte-ltd-gsd8j60m-595wt/) G-Star Pte Ltd | 595.0 W | +5.0 W | 41.4 V | 21.17% | 94.2% |
| [**CSI Solar Co Ltd CS7L-585MS-R**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs7l-585ms-r/) CSI Solar Co Ltd | 585.0 W | -5.0 W | 40.7 V | 20.89% | 94.0% |
| [**Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-590**](https://epri-peac.com/solar-equipment/modules/chint-new-energy-technology-co-ltd/chint-new-energy-technology-co-ltd-chsm66rn-dg-f-bh-590/) Chint New Energy Technology Co Ltd | 590.0 W | Tie (0 W) | 48.14 V | 21.85% | 95.3% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Venus Energy Limited VE-590-60IIMK?

Evaluate Venus Energy Limited VE-590-60IIMK (590.0 W STC, 41.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Venus Energy Limited VE-590-60IIMK reaches 46.24 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 428 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Venus Energy Limited VE-590-60IIMK carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Venus Energy Limited VE-590-60IIMK 8 kW Residential Fit

Needs 14 modules (428 sq ft) with a 30 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare G-Star Pte Ltd GSD8J60M-595BT.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 553.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Venus Energy Limited VE-590-60IIMK by Venus Energy Limited grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Venus Energy Limited VE-590-60IIMK PTC wattage (553.6 W) lower than STC (590.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 553.6 W PTC (93.8% retention) across Venus Energy Limited VE-590-60IIMK's 2.84 m2 aperture.

### Who should skip Venus Energy Limited VE-590-60IIMK on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Venus Energy Limited VE-590-60IIMK panels (428 sq ft) leave unusable roof gaps vs. G-Star Pte Ltd GSD8J60M-595BT.

### What is the 1,000 V commercial string limit for Venus Energy Limited VE-590-60IIMK?

On 1,000 V commercial inverters at -10 C (45.18 V cold Voc), Venus Energy Limited VE-590-60IIMK fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Venus Energy Limited VE-590-60IIMK.

## Related Pages

Compare Venus Energy Limited equipment, G-Star Pte Ltd GSD8J60M-595BT specs, utility payback rates, and NEC string calculators alongside Venus Energy Limited VE-590-60IIMK.

[All Venus Energy Limited Certified Solar Models](https://epri-peac.com/solar-equipment/brands/venus-energy-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Venus Energy Limited

- [All Venus Energy Limited Specs](https://epri-peac.com/solar-equipment/brands/venus-energy-limited/)
- [Venus Energy Limited VE-655-66IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-655-66iimk/)
- [Venus Energy Limited VE-635-66IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-635-66iimk/)
- [Venus Energy Limited VE-620-66IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-620-66iimk/)
- [Venus Energy Limited VE-600-60IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-600-60iimk/)
- [Venus Energy Limited VE-560-60IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-560-60iimk/)