title: "Venus Energy Limited VE-390-54IIMJ Specs (390.0W, 36.34V Voc)"
url: https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-390-54iimj/
description: "CEC datasheet for Venus Energy Limited VE-390-54IIMJ: 390.0W STC, 36.34V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# Venus Energy Limited VE-390-54IIMJ — CEC Solar Module Specifications

Manufacturer: [**Venus Energy Limited**](https://epri-peac.com/solar-equipment/brands/venus-energy-limited/) Registry: **CEC Verified Engineering Specification**

Venus Energy Limited VE-390-54IIMJ is a 390.0 W STC (366.5 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.0% efficiency, 36.34 V Voc at 25 C, and 39.57 V cold Voc at -10 C (15 panels max per 600 V string).

- **STC Wattage** : 390.0 W

- **PTC Wattage** : 366.5 W

- **Voc @ 25C** : 36.34 V

- **Efficiency** : 20.0%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Venus Energy Limited VE-390-54IIMJ Compare Against Peer CEC Listings?

How Venus Energy Limited Venus Energy Limited VE-390-54IIMJ handles rooftop heat (366.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Venus Energy Limited VE-390-54IIMJ exhibits 13.65 A short-circuit current, requiring a 21.29 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #10,321 of 21,677 (20.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.9 m2 for an 8 kW system (26 panels for 10 kW). Lower 36.34 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.

## Where Does Venus Energy Limited VE-390-54IIMJ Fall Across Listed CEC Models?

Where Venus Energy Limited VE-390-54IIMJ (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Venus Energy Limited VE-390-54IIMJ?

Percentile placement of Venus Energy Limited VE-390-54IIMJ across power density (200.0 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Venus Energy Limited VE-390-54IIMJ?

Four critical engineering numbers homeowners and solar installers check first when reviewing Venus Energy Limited VE-390-54IIMJ specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #10,321 / 21,677

### Top 49.5% STC Output

390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,442

### 20.0% Aperture Efficiency

Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

### 15 Panels Max @ -10 C (600 V)

Cold Voc reaches 39.57 V at -10 C (593.5 V string) and 40.49 V at -20 C (14 max).

 8 kW Reference Array

### 21 Panels = 8,190 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,696 W PTC; NEC 690.8 OCPD floor is 21.29 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.34 * (1 + (-0.254/100) * (-10 - 25)) = 39.57 V | OCPD = 1.56 * 13.65 = 21.29 A

Inputs from CEC Modules.csv for Venus Energy Limited VE-390-54IIMJ: Voc=36.34 V, beta_Voc=-0.254%/C, Isc=13.65 A, STC=390.0 W, Area=1.95 m2.

**Result:** 15 panels max on 600 V (593.5 V); 21 panels for 8 kW (441 sq ft).

## What Are the Published CEC Specifications for Venus Energy Limited VE-390-54IIMJ?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Venus Energy Limited VE-390-54IIMJ.

Official California Energy Commission (NREL SAM) test parameters for Venus Energy Limited VE-390-54IIMJ.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 366.5 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.34 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 30.28 V / 12.88 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.254 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.0% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Venus Energy Limited VE-390-54IIMJ Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Venus Energy Limited VE-390-54IIMJ (390.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.24 kW | 336 sq ft | $1,562 | $2,641 |
| **8 kW Class** | 21 | 8.19 kW | 441 sq ft | $2,050 | $3,466 |
| **10 kW Class** | 26 | 10.14 kW | 546 sq ft | $2,538 | $4,292 |

## Which Sibling Wattage & Trim Variants Belong to This Venus Energy Limited Series?

All closely matched Venus Energy Limited wattages and cosmetic trims sharing the Venus Energy Limited VE-390-54IIMJ architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Venus Energy Limited VE-390-54IIMJ wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Venus Energy Limited VE-380-54IIMJ** | 380.0 W | 356.9 W | 36.05 V | 30.04 V | 19.49% |
| **Venus Energy Limited VE-385-54IIMJ** | 385.0 W | 361.7 W | 36.19 V | 30.16 V | 19.74% |
| **Venus Energy Limited VE-390-54IIMJ** | 390.0 W | 366.5 W | 36.34 V | 30.28 V | 20.0% |
| **Venus Energy Limited VE-395-54IIMJ** | 395.0 W | 371.3 W | 36.51 V | 30.42 V | 20.26% |

## How Many Venus Energy Limited VE-390-54IIMJ Modules Fit in a Cold-Weather String?

Maximum series module counts for Venus Energy Limited VE-390-54IIMJ from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.34V and beta_Voc=-0.254%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 40.49 V | 14 panels | 566.9 V | 24 panels |
| **-10 C (14 F)** | 39.57 V | 15 panels | 593.5 V | 25 panels |
| **0 C (32 F)** | 38.65 V | 15 panels | 579.8 V | 25 panels |
| **25 C (77 F STC)** | 36.34 V | 16 panels | 581.4 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to Venus Energy Limited VE-390-54IIMJ?

Alternative CEC solar modules from competing brands near Venus Energy Limited VE-390-54IIMJ (390.0 W), including CSI Solar Co Ltd CS6R-390MS-HL {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS6R-390MS-HL {Blk}**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-390ms-hl-blk/) CSI Solar Co Ltd | 390.0 W | Tie (0 W) | 36.4 V | 20.0% | 94.1% |
| [**DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M**](https://epri-peac.com/solar-equipment/modules/dongguan-sunworth-solar-energy-co-ltd/dongguan-sunworth-solar-energy-co-ltd-sw390m/) DONGGUAN SUNWORTH SOLAR ENERGY CO LTD | 390.0 W | Tie (0 W) | 36.45 V | 20.53% | 94.4% |
| [**Apollo Renewables Inc Apollo-M754BH-390BB**](https://epri-peac.com/solar-equipment/modules/apollo-renewables-inc/apollo-renewables-inc-apollo-m754bh-390bb/) Apollo Renewables Inc | 390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |
| [**AXITEC AC-390MH/108VB**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-390mh-108vb/) AXITEC | 390.0 W | Tie (0 W) | 36.85 V | 20.1% | 93.7% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Venus Energy Limited VE-390-54IIMJ?

Evaluate Venus Energy Limited VE-390-54IIMJ (390.0 W STC, 36.34 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Venus Energy Limited VE-390-54IIMJ reaches 40.49 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Venus Energy Limited VE-390-54IIMJ carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Venus Energy Limited VE-390-54IIMJ 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-390MS-HL {Blk}.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 366.5 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Venus Energy Limited VE-390-54IIMJ by Venus Energy Limited grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is Venus Energy Limited VE-390-54IIMJ PTC wattage (366.5 W) lower than STC (390.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 366.5 W PTC (94.0% retention) across Venus Energy Limited VE-390-54IIMJ's 1.95 m2 aperture.

### Who should skip Venus Energy Limited VE-390-54IIMJ on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 Venus Energy Limited VE-390-54IIMJ panels (441 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6R-390MS-HL {Blk}.

### What is the 1,000 V commercial string limit for Venus Energy Limited VE-390-54IIMJ?

On 1,000 V commercial inverters at -10 C (39.57 V cold Voc), Venus Energy Limited VE-390-54IIMJ fits up to 25 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Venus Energy Limited VE-390-54IIMJ.

## Related Pages

Compare Venus Energy Limited equipment, CSI Solar Co Ltd CS6R-390MS-HL {Blk} specs, utility payback rates, and NEC string calculators alongside Venus Energy Limited VE-390-54IIMJ.

[All Venus Energy Limited Certified Solar Models](https://epri-peac.com/solar-equipment/brands/venus-energy-limited/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Venus Energy Limited

- [All Venus Energy Limited Specs](https://epri-peac.com/solar-equipment/brands/venus-energy-limited/)
- [Venus Energy Limited VE-655-66IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-655-66iimk/)
- [Venus Energy Limited VE-635-66IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-635-66iimk/)
- [Venus Energy Limited VE-620-66IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-620-66iimk/)
- [Venus Energy Limited VE-600-60IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-600-60iimk/)
- [Venus Energy Limited VE-590-60IIMK](https://epri-peac.com/solar-equipment/modules/venus-energy-limited/venus-energy-limited-ve-590-60iimk/)