US Solar USS-QCMO3-72-310 is a 310.0 W STC (281.4 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.94% efficiency, 45.7 V Voc at 25 C, and 50.88 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 281.4 W

- **Voc @ 25C** : 45.7 V

- **Efficiency** : 15.94%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does US Solar USS-QCMO3-72-310 Compare Against Peer CEC Listings?

How US Solar US Solar USS-QCMO3-72-310 handles rooftop heat (281.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, US Solar USS-QCMO3-72-310 exhibits 8.8 A short-circuit current, requiring a 13.73 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #15,760 of 21,677 (100.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 50.5 m2 for an 8 kW system (33 panels for 10 kW). Mid-range 45.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does US Solar USS-QCMO3-72-310 Fall Across Listed CEC Models?

Where US Solar USS-QCMO3-72-310 (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define US Solar USS-QCMO3-72-310?

Percentile placement of US Solar USS-QCMO3-72-310 across power density (159.5 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for US Solar USS-QCMO3-72-310?

Four critical engineering numbers homeowners and solar installers check first when reviewing US Solar USS-QCMO3-72-310 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,273

### 15.94% Aperture Efficiency

Power density 159.5 W/m2 (3.97 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.88 V at -10 C (559.7 V string) and 52.36 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.5 m2 (544 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.7 * (1 + (-0.324/100) * (-10 - 25)) = 50.88 V | OCPD = 1.56 * 8.8 = 13.73 A

Inputs from CEC Modules.csv for US Solar USS-QCMO3-72-310: Voc=45.7 V, beta_Voc=-0.324%/C, Isc=8.8 A, STC=310.0 W, Area=1.944 m2.

**Result:** 11 panels max on 600 V (559.7 V); 26 panels for 8 kW (544 sq ft).

## What Are the Published CEC Specifications for US Solar USS-QCMO3-72-310?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for US Solar USS-QCMO3-72-310.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMO3-72-310.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 281.4 W (90.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.9 V / 8.2 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.324 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.94% (1.944 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Mono-c-Si) | Monofacial backsheet |

## How Many US Solar USS-QCMO3-72-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using US Solar USS-QCMO3-72-310 (310.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 419 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 544 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 691 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

All closely matched US Solar wattages and cosmetic trims sharing the US Solar USS-QCMO3-72-310 architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the US Solar USS-QCMO3-72-310 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **US Solar USS-QCMO3-72-300** | 300.0 W | 272.1 W | 45.0 V | 37.1 V | 15.43% |
| **US Solar USS-QCMO3-72-305** | 305.0 W | 276.8 W | 45.4 V | 37.2 V | 15.69% |
| **US Solar USS-QCMO3-72-310** | 310.0 W | 281.4 W | 45.7 V | 37.9 V | 15.94% |
| **US Solar USS-QCMO3-72-315** | 315.0 W | 286.1 W | 46.0 V | 38.0 V | 16.2% |
| **US Solar USS-QCMO3-72-320** | 320.0 W | 290.8 W | 46.3 V | 38.6 V | 16.46% |

## How Many US Solar USS-QCMO3-72-310 Modules Fit in a Cold-Weather String?

Maximum series module counts for US Solar USS-QCMO3-72-310 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.7V and beta_Voc=-0.324%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.36 V | 11 panels | 576.0 V | 19 panels |
| **-10 C (14 F)** | 50.88 V | 11 panels | 559.7 V | 19 panels |
| **0 C (32 F)** | 49.4 V | 12 panels | 592.8 V | 20 panels |
| **25 C (77 F STC)** | 45.7 V | 13 panels | 594.1 V | 21 panels |

## Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-72-310?

Alternative CEC solar modules from competing brands near US Solar USS-QCMO3-72-310 (310.0 W), including Centrosolar America DM72 310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm72-310/) Centrosolar America | 310.0 W | Tie (0 W) | 45.7 V | 15.94% | 90.8% |
| [**Centrosolar America TP7 310xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7-310xx/) Centrosolar America | 310.0 W | Tie (0 W) | 45.7 V | 15.89% | 90.5% |
| [**Centrosolar America TP7S 310xx**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-tp7s-310xx/) Centrosolar America | 310.0 W | Tie (0 W) | 45.7 V | 15.89% | 90.5% |
| [**BYD Company Limited BYD 310P6C-36**](https://epri-peac.com/solar-equipment/modules/byd-company-limited/byd-company-limited-byd-310p6c-36/) BYD Company Limited | 310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-72-310?

Evaluate US Solar USS-QCMO3-72-310 (310.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-72-310 reaches 52.36 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 544 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (544 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-72-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### US Solar USS-QCMO3-72-310 8 kW Residential Fit

Needs 26 modules (544 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DM72 310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMO3-72-310 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is US Solar USS-QCMO3-72-310 PTC wattage (281.4 W) lower than STC (310.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 281.4 W PTC (90.8% retention) across US Solar USS-QCMO3-72-310's 1.944 m2 aperture.

### Who should skip US Solar USS-QCMO3-72-310 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 US Solar USS-QCMO3-72-310 panels (544 sq ft) leave unusable roof gaps vs. Centrosolar America DM72 310.

### What is the 1,000 V commercial string limit for US Solar USS-QCMO3-72-310?

On 1,000 V commercial inverters at -10 C (50.88 V cold Voc), US Solar USS-QCMO3-72-310 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting US Solar USS-QCMO3-72-310.

## Related Pages

Compare US Solar equipment, Centrosolar America DM72 310 specs, utility payback rates, and NEC string calculators alongside US Solar USS-QCMO3-72-310.

[All US Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/us-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From US Solar

- [All US Solar Specs](https://epri-peac.com/solar-equipment/brands/us-solar/)
- [US Solar USS-QCMI3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-330/)
- [US Solar USS-QCMO3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-330/)
- [US Solar USS-QCMI3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-310/)
- [US Solar USS-QCMI2-72-305](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-72-305/)
- [US Solar USS-QCMI3-72-290](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-290/)