title: "US Solar USS-QCMO3-60-275 Specs (275.0W, 39.1V Voc)"
url: https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-60-275/
description: "CEC datasheet for US Solar USS-QCMO3-60-275: 275.0W STC, 39.1V Voc, 30-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# US Solar USS-QCMO3-60-275 — CEC Solar Module Specifications

Manufacturer: [**US Solar**](https://epri-peac.com/solar-equipment/brands/us-solar/) Registry: **CEC Verified Engineering Specification**

US Solar USS-QCMO3-60-275 is a 275.0 W STC (250.0 W PTC) Mono-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.77% efficiency, 39.1 V Voc at 25 C, and 43.53 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 275.0 W

- **PTC Wattage** : 250.0 W

- **Voc @ 25C** : 39.1 V

- **Efficiency** : 16.77%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does US Solar USS-QCMO3-60-275 Compare Against Peer CEC Listings?

Engineering position of US Solar USS-QCMO3-60-275 (275.0 W STC) vs. Centrosolar America DM60 275 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, US Solar USS-QCMO3-60-275 pairs typical 90.9% PTC-to-STC thermal output (250.0 W real-world rating) with 39.1 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,500 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM60 275 offers a 275.0 W alternative.

## Where Does US Solar USS-QCMO3-60-275 Fall Across Listed CEC Models?

Plots US Solar USS-QCMO3-60-275 at 275.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define US Solar USS-QCMO3-60-275?

Benchmarks US Solar USS-QCMO3-60-275 on STC wattage, thermal PTC/STC retention, and 16.77 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for US Solar USS-QCMO3-60-275?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for US Solar USS-QCMO3-60-275 by US Solar.

Rank #18,259 / 21,677

### 275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,838

### 16.77% Aperture Efficiency

Power density 167.7 W/m2 (3.14 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.53 V at -10 C (565.9 V string) and 44.8 V at -20 C (13 max).

 8 kW Reference Array

### 30 Panels = 8,250 W STC

Occupies 49.2 m2 (530 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.1 * (1 + (-0.324/100) * (-10 - 25)) = 43.53 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for US Solar USS-QCMO3-60-275: Voc=39.1 V, beta_Voc=-0.324%/C, Isc=9.0 A, STC=275.0 W, Area=1.64 m2.

**Result:** 13 panels max on 600 V (565.9 V); 30 panels for 8 kW (530 sq ft).

## What Are the Published CEC Specifications for US Solar USS-QCMO3-60-275?

Laboratory test ratings recorded for US Solar USS-QCMO3-60-275 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMO3-60-275.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 250.0 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.8 V / 8.4 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.324 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 16.77% (1.64 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many US Solar USS-QCMO3-60-275 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (530 sq ft at 8 kW), and estimated Year-1 electric bill offset for US Solar USS-QCMO3-60-275.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 22 | 6.05 kW | 388 sq ft | $1,514 | $2,561 |
| **8 kW Class** | 30 | 8.25 kW | 530 sq ft | $2,065 | $3,492 |
| **10 kW Class** | 37 | 10.18 kW | 653 sq ft | $2,548 | $4,308 |

## How Many US Solar USS-QCMO3-60-275 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for US Solar USS-QCMO3-60-275 (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=39.1V and beta_Voc=-0.324%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.8 V | 13 panels | 582.4 V | 22 panels |
| **-10 C (14 F)** | 43.53 V | 13 panels | 565.9 V | 22 panels |
| **0 C (32 F)** | 42.27 V | 14 panels | 591.8 V | 23 panels |
| **25 C (77 F STC)** | 39.1 V | 15 panels | 586.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-60-275?

Closest cross-brand CEC competitors to US Solar USS-QCMO3-60-275 matched near 275.0 W STC and 39.1 V Voc, led by Centrosolar America DM60 275.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM60 275**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm60-275/) Centrosolar America | 275.0 W | Tie (0 W) | 39.1 V | 16.77% | 90.9% |
| [**Flextronics FXS-275BB-SAC1B**](https://epri-peac.com/solar-equipment/modules/flextronics/flextronics-fxs-275bb-sac1b/) Flextronics | 275.0 W | Tie (0 W) | 38.6 V | 16.75% | 91.4% |
| [**AXITEC AC-275P/60S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-275p-60s/) AXITEC | 275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| [**AXITEC AC-275P/60V**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-275p-60v/) AXITEC | 275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-60-275?

Evaluate US Solar USS-QCMO3-60-275 (275.0 W STC, 39.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-60-275 reaches 44.8 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 530 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (530 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-60-275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### US Solar USS-QCMO3-60-275 8 kW Residential Fit

Needs 30 modules (530 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 275.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMO3-60-275 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMO3-60-275?

Multiplying US Solar USS-QCMO3-60-275's 9.0 A short-circuit current by 1.56 equals 14.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can US Solar USS-QCMO3-60-275 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.53 V cold Voc at 14 F and handles 9.0 A Isc; string inverters cap US Solar USS-QCMO3-60-275 at 13 panels on 600 V.

### Is US Solar USS-QCMO3-60-275 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMO3-60-275 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

## Related Pages

Compare US Solar equipment, Centrosolar America DM60 275 specs, utility payback rates, and NEC string calculators alongside US Solar USS-QCMO3-60-275.

[All US Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/us-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From US Solar

- [All US Solar Specs](https://epri-peac.com/solar-equipment/brands/us-solar/)
- [US Solar USS-QCMI3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-330/)
- [US Solar USS-QCMO3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-330/)
- [US Solar USS-QCMI3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-310/)
- [US Solar USS-QCMO3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-310/)
- [US Solar USS-QCMI2-72-305](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-72-305/)