title: "US Solar USS-QCMO3-60-240 Specs (240.0W, 36.8V Voc)"
url: https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-60-240/
description: "CEC datasheet for US Solar USS-QCMO3-60-240: 240.0W STC, 36.8V Voc, 34-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# US Solar USS-QCMO3-60-240 — CEC Solar Module Specifications

Manufacturer: [**US Solar**](https://epri-peac.com/solar-equipment/brands/us-solar/) Registry: **CEC Verified Engineering Specification**

US Solar USS-QCMO3-60-240 is a 240.0 W STC (217.4 W PTC) Mono-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.64% efficiency, 36.8 V Voc at 25 C, and 40.97 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 240.0 W

- **PTC Wattage** : 217.4 W

- **Voc @ 25C** : 36.8 V

- **Efficiency** : 14.64%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does US Solar USS-QCMO3-60-240 Compare Against Peer CEC Listings?

Engineering position of US Solar USS-QCMO3-60-240 (240.0 W STC) vs. Centrosolar America DM60 240 across 5,889 CEC Mono-c-Si solar modules.

Built with 60 Mono-c-Si cells, US Solar USS-QCMO3-60-240 pairs typical 90.6% PTC-to-STC thermal output (217.4 W real-world rating) with 36.8 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,392 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America DM60 240 offers a 240.0 W alternative.

## Where Does US Solar USS-QCMO3-60-240 Fall Across Listed CEC Models?

Plots US Solar USS-QCMO3-60-240 at 240.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

## What Dataset Percentiles Define US Solar USS-QCMO3-60-240?

Benchmarks US Solar USS-QCMO3-60-240 on STC wattage, thermal PTC/STC retention, and 14.64 aperture conversion efficiency against CEC peers.

## What Do the Dataset Ranks Show for US Solar USS-QCMO3-60-240?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for US Solar USS-QCMO3-60-240 by US Solar.

Rank #20,160 / 21,677

### 240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,260

### 14.64% Aperture Efficiency

Power density 146.3 W/m2 (5.27 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.97 V at -10 C (573.6 V string) and 42.17 V at -20 C (14 max).

 8 kW Reference Array

### 34 Panels = 8,160 W STC

Occupies 55.8 m2 (600 sq ft) producing 7,392 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.8 * (1 + (-0.324/100) * (-10 - 25)) = 40.97 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for US Solar USS-QCMO3-60-240: Voc=36.8 V, beta_Voc=-0.324%/C, Isc=8.6 A, STC=240.0 W, Area=1.64 m2.

**Result:** 14 panels max on 600 V (573.6 V); 34 panels for 8 kW (600 sq ft).

## What Are the Published CEC Specifications for US Solar USS-QCMO3-60-240?

Laboratory test ratings recorded for US Solar USS-QCMO3-60-240 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMO3-60-240.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 240.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 217.4 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 36.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.7 V / 8.1 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.324 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.64% (1.64 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many US Solar USS-QCMO3-60-240 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (600 sq ft at 8 kW), and estimated Year-1 electric bill offset for US Solar USS-QCMO3-60-240.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 25 | 6.0 kW | 441 sq ft | $1,502 | $2,539 |
| **8 kW Class** | 34 | 8.16 kW | 600 sq ft | $2,042 | $3,454 |
| **10 kW Class** | 42 | 10.08 kW | 741 sq ft | $2,523 | $4,266 |

## Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Sibling wattage bins and frame colors grouped with US Solar USS-QCMO3-60-240 under US Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the US Solar USS-QCMO3-60-240 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **US Solar USS-QCMO3-60-230** | 230.0 W | 208.1 W | 36.2 V | 28.8 V | 14.03% |
| **US Solar USS-QCMO3-60-235** | 235.0 W | 212.8 W | 36.5 V | 29.4 V | 14.33% |
| **US Solar USS-QCMO3-60-240** | 240.0 W | 217.4 W | 36.8 V | 29.7 V | 14.64% |
| **US Solar USS-QCMO3-60-245** | 245.0 W | 222.0 W | 37.1 V | 30.3 V | 14.94% |

## How Many US Solar USS-QCMO3-60-240 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for US Solar USS-QCMO3-60-240 (beta_Voc -0.324%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.8V and beta_Voc=-0.324%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.17 V | 14 panels | 590.4 V | 23 panels |
| **-10 C (14 F)** | 40.97 V | 14 panels | 573.6 V | 24 panels |
| **0 C (32 F)** | 39.78 V | 15 panels | 596.7 V | 25 panels |
| **25 C (77 F STC)** | 36.8 V | 16 panels | 588.8 V | 27 panels |

## Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMO3-60-240?

Closest cross-brand CEC competitors to US Solar USS-QCMO3-60-240 matched near 240.0 W STC and 36.8 V Voc, led by Centrosolar America DM60 240.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DM60 240**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dm60-240/) Centrosolar America | 240.0 W | Tie (0 W) | 36.8 V | 14.64% | 90.6% |
| [**Heliene 60M240**](https://epri-peac.com/solar-equipment/modules/heliene/heliene-60m240/) Heliene | 240.0 W | Tie (0 W) | 36.8 V | 14.43% | 90.1% |
| [**Eoplly New Energy Technology EP156M/60-240S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156m-60-240s-ac/) Eoplly New Energy Technology | 240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.7% |
| [**Eoplly New Energy Technology EP156MB/60-240S AC**](https://epri-peac.com/solar-equipment/modules/eoplly-new-energy-technology/eoplly-new-energy-technology-ep156mb-60-240s-ac/) Eoplly New Energy Technology | 240.0 W | Tie (0 W) | 36.9 V | 14.83% | 89.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMO3-60-240?

Evaluate US Solar USS-QCMO3-60-240 (240.0 W STC, 36.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMO3-60-240 reaches 42.17 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 34 panels for an 8 kW build require 600 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (600 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMO3-60-240 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### US Solar USS-QCMO3-60-240 8 kW Residential Fit

Needs 34 modules (600 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DM60 240.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 217.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMO3-60-240 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMO3-60-240?

Multiplying US Solar USS-QCMO3-60-240's 8.6 A short-circuit current by 1.56 equals 13.42 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can US Solar USS-QCMO3-60-240 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.97 V cold Voc at 14 F and handles 8.6 A Isc; string inverters cap US Solar USS-QCMO3-60-240 at 14 panels on 600 V.

### Is US Solar USS-QCMO3-60-240 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMO3-60-240 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

## Related Pages

Compare US Solar equipment, Centrosolar America DM60 240 specs, utility payback rates, and NEC string calculators alongside US Solar USS-QCMO3-60-240.

[All US Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/us-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From US Solar

- [All US Solar Specs](https://epri-peac.com/solar-equipment/brands/us-solar/)
- [US Solar USS-QCMI3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-330/)
- [US Solar USS-QCMO3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-330/)
- [US Solar USS-QCMI3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-310/)
- [US Solar USS-QCMO3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-310/)
- [US Solar USS-QCMI2-72-305](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-72-305/)