title: "US Solar USS-QCMI3-72-310 Specs (310.0W, 45.18V Voc)"
url: https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-310/
description: "CEC datasheet for US Solar USS-QCMI3-72-310: 310.0W STC, 45.18V Voc, 26-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# US Solar USS-QCMI3-72-310 — CEC Solar Module Specifications

Manufacturer: [**US Solar**](https://epri-peac.com/solar-equipment/brands/us-solar/) Registry: **CEC Verified Engineering Specification**

US Solar USS-QCMI3-72-310 is a 310.0 W STC (279.6 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.94% efficiency, 45.18 V Voc at 25 C, and 50.54 V cold Voc at -10 C (11 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 279.6 W

- **Voc @ 25C** : 45.18 V

- **Efficiency** : 15.94%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does US Solar USS-QCMI3-72-310 Compare Against Peer CEC Listings?

Solar engineering breakdown for US Solar USS-QCMI3-72-310: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Across 1,407 Multi-c-Si listings from US Solar and peers, US Solar USS-QCMI3-72-310 stands 31.2 W above the 278.8 W Multi-c-Si median and typical 90.2% PTC-to-STC thermal output (279.6 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 45.18 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

## Where Does US Solar USS-QCMI3-72-310 Fall Across Listed CEC Models?

Distribution marker showing US Solar USS-QCMI3-72-310 (310.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

## What Dataset Percentiles Define US Solar USS-QCMI3-72-310?

Dataset percentiles tracking US Solar USS-QCMI3-72-310 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

## What Do the Dataset Ranks Show for US Solar USS-QCMI3-72-310?

Benchmark highlights for US Solar USS-QCMI3-72-310 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,273

### 15.94% Aperture Efficiency

Power density 159.5 W/m2 (3.97 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).

NEC 690.7 Limit

### 11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.54 V at -10 C (555.9 V string) and 52.07 V at -20 C (11 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 50.5 m2 (544 sq ft) producing 7,270 W PTC; NEC 690.8 OCPD floor is 13.57 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.18 * (1 + (-0.339/100) * (-10 - 25)) = 50.54 V | OCPD = 1.56 * 8.7 = 13.57 A

Inputs from CEC Modules.csv for US Solar USS-QCMI3-72-310: Voc=45.18 V, beta_Voc=-0.339%/C, Isc=8.7 A, STC=310.0 W, Area=1.944 m2.

**Result:** 11 panels max on 600 V (555.9 V); 26 panels for 8 kW (544 sq ft).

## What Are the Published CEC Specifications for US Solar USS-QCMI3-72-310?

Official CEC datasheet figures for US Solar USS-QCMI3-72-310 (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI3-72-310.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 279.6 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 45.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 37.3 V / 8.31 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.339 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 15.94% (1.944 m2) | Array roof footprint density |
| **Cell Count & Technology** | 72 cells (Multi-c-Si) | Monofacial backsheet |

## How Many US Solar USS-QCMI3-72-310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many US Solar USS-QCMI3-72-310 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 419 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 544 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 691 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Consolidated US Solar wattage variants sharing the US Solar USS-QCMI3-72-310 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the US Solar USS-QCMI3-72-310 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **US Solar USS-QCMI3-72-300** | 300.0 W | 270.3 W | 44.75 V | 36.45 V | 15.43% |
| **US Solar USS-QCMI3-72-305** | 305.0 W | 274.9 W | 44.83 V | 36.53 V | 15.69% |
| **US Solar USS-QCMI3-72-310** | 310.0 W | 279.6 W | 45.18 V | 37.3 V | 15.94% |
| **US Solar USS-QCMI3-72-315** | 315.0 W | 284.2 W | 45.32 V | 37.58 V | 16.2% |
| **US Solar USS-QCMI3-72-320** | 320.0 W | 288.8 W | 45.5 V | 38.0 V | 16.46% |

## How Many US Solar USS-QCMI3-72-310 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI3-72-310 (50.54 V at 14 F).

Computed from Voc=45.18V and beta_Voc=-0.339%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 52.07 V | 11 panels | 572.8 V | 19 panels |
| **-10 C (14 F)** | 50.54 V | 11 panels | 555.9 V | 19 panels |
| **0 C (32 F)** | 49.01 V | 12 panels | 588.1 V | 20 panels |
| **25 C (77 F STC)** | 45.18 V | 13 panels | 587.3 V | 22 panels |

## Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-72-310?

Competing CEC solar panels closest to US Solar USS-QCMI3-72-310 in nameplate wattage and Voc, starting with Centrosolar America DP72 310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Centrosolar America DP72 310**](https://epri-peac.com/solar-equipment/modules/centrosolar-america/centrosolar-america-dp72-310/) Centrosolar America | 310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| [**Advance Power API-P310**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-p310/) Advance Power | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**Auxin Solar AXN6P612T310**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6p612t310/) Auxin Solar | 310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| [**AXITEC AC-310P/156-72S**](https://epri-peac.com/solar-equipment/modules/axitec/axitec-ac-310p-156-72s/) AXITEC | 310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-72-310?

Evaluate US Solar USS-QCMI3-72-310 (310.0 W STC, 45.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-72-310 reaches 52.07 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 544 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (544 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-72-310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### US Solar USS-QCMI3-72-310 8 kW Residential Fit

Needs 26 modules (544 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.6 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI3-72-310 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for US Solar USS-QCMI3-72-310?

Multiplying US Solar USS-QCMI3-72-310's 8.7 A short-circuit current by 1.56 equals 13.57 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

### Can US Solar USS-QCMI3-72-310 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.54 V cold Voc at 14 F and handles 8.7 A Isc; string inverters cap US Solar USS-QCMI3-72-310 at 11 panels on 600 V.

### Is US Solar USS-QCMI3-72-310 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of US Solar USS-QCMI3-72-310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

## Related Pages

Compare US Solar equipment, Centrosolar America DP72 310 specs, utility payback rates, and NEC string calculators alongside US Solar USS-QCMI3-72-310.

[All US Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/us-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From US Solar

- [All US Solar Specs](https://epri-peac.com/solar-equipment/brands/us-solar/)
- [US Solar USS-QCMI3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-330/)
- [US Solar USS-QCMO3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-330/)
- [US Solar USS-QCMO3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-310/)
- [US Solar USS-QCMI2-72-305](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-72-305/)
- [US Solar USS-QCMI3-72-290](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-290/)