# US Solar USS-QCMI3-60-235 — CEC Solar Module Specifications

Manufacturer: [**US Solar**](https://epri-peac.com/solar-equipment/brands/us-solar/) Registry: **CEC Verified Engineering Specification**

US Solar USS-QCMI3-60-235 is a 235.0 W STC (211.3 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.33% efficiency, 37.5 V Voc at 25 C, and 41.95 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 235.0 W

- **PTC Wattage** : 211.3 W

- **Voc @ 25C** : 37.5 V

- **Efficiency** : 14.33%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does US Solar USS-QCMI3-60-235 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for US Solar USS-QCMI3-60-235 (Multi-c-Si) residential solar systems.

Homeowners evaluating US Solar USS-QCMI3-60-235 need 26 panels for 6 kW or 35 panels (618 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (618 sq ft). Under NEC 690.7(A), beta_Voc (-0.339%/C) pushes open-circuit voltage to 41.95 V at 14 F and 43.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

## Where Does US Solar USS-QCMI3-60-235 Fall Across Listed CEC Models?

Comparison of US Solar USS-QCMI3-60-235 (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

## What Dataset Percentiles Define US Solar USS-QCMI3-60-235?

Relative ranking of US Solar USS-QCMI3-60-235 across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

## What Do the Dataset Ranks Show for US Solar USS-QCMI3-60-235?

Summary of US Solar USS-QCMI3-60-235 output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.

Rank #20,368 / 21,677

### 235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,596

### 14.33% Aperture Efficiency

Power density 143.3 W/m2 (5.58 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.95 V at -10 C (587.3 V string) and 43.22 V at -20 C (13 max).

 8 kW Reference Array

### 35 Panels = 8,225 W STC

Occupies 57.4 m2 (618 sq ft) producing 7,396 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.5 * (1 + (-0.339/100) * (-10 - 25)) = 41.95 V | OCPD = 1.56 * 8.35 = 13.03 A

Inputs from CEC Modules.csv for US Solar USS-QCMI3-60-235: Voc=37.5 V, beta_Voc=-0.339%/C, Isc=8.35 A, STC=235.0 W, Area=1.64 m2.

**Result:** 14 panels max on 600 V (587.3 V); 35 panels for 8 kW (618 sq ft).

## What Are the Published CEC Specifications for US Solar USS-QCMI3-60-235?

Complete CEC test sheet for US Solar USS-QCMI3-60-235 including Isc (8.35 A), Voc (37.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI3-60-235.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 211.3 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 8.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 29.87 V / 7.87 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.339 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 14.33% (1.64 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Multi-c-Si) | Monofacial backsheet |

## How Many US Solar USS-QCMI3-60-235 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using US Solar USS-QCMI3-60-235.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 26 | 6.11 kW | 459 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 35 | 8.22 kW | 618 sq ft | $2,057 | $3,479 |
| **10 kW Class** | 43 | 10.11 kW | 759 sq ft | $2,530 | $4,279 |

## Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

Related US Solar power steps and black/silver trims consolidated into this US Solar USS-QCMI3-60-235 series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the US Solar USS-QCMI3-60-235 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **US Solar USS-QCMI3-60-225** | 225.0 W | 202.1 W | 36.8 V | 29.26 V | 13.72% |
| **US Solar USS-QCMI3-60-230** | 230.0 W | 206.7 W | 37.34 V | 29.49 V | 14.03% |
| **US Solar USS-QCMI3-60-235** | 235.0 W | 211.3 W | 37.5 V | 29.87 V | 14.33% |
| **US Solar USS-QCMI3-60-240** | 240.0 W | 215.9 W | 37.82 V | 30.04 V | 14.64% |
| **US Solar USS-QCMI3-60-245** | 245.0 W | 220.5 W | 38.0 V | 30.19 V | 14.94% |

## How Many US Solar USS-QCMI3-60-235 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for US Solar USS-QCMI3-60-235 (37.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.5V and beta_Voc=-0.339%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 43.22 V | 13 panels | 561.9 V | 23 panels |
| **-10 C (14 F)** | 41.95 V | 14 panels | 587.3 V | 23 panels |
| **0 C (32 F)** | 40.68 V | 14 panels | 569.5 V | 24 panels |
| **25 C (77 F STC)** | 37.5 V | 16 panels | 600.0 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-60-235?

Four comparable CEC modules such as Advance Power API-M235 (235.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Advance Power API-M235**](https://epri-peac.com/solar-equipment/modules/advance-power/advance-power-api-m235/) Advance Power | 235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| [**Auxin Solar AXN6M610T235**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn6m610t235/) Auxin Solar | 235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| [**APOS Energy AS235**](https://epri-peac.com/solar-equipment/modules/apos-energy/apos-energy-as235/) APOS Energy | 235.0 W | Tie (0 W) | 37.34 V | 14.17% | 89.7% |
| [**Gintech Energy GTE 235M**](https://epri-peac.com/solar-equipment/modules/gintech-energy/gintech-energy-gte-235m/) Gintech Energy | 235.0 W | Tie (0 W) | 37.32 V | 13.97% | 89.5% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-60-235?

Evaluate US Solar USS-QCMI3-60-235 (235.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-60-235 reaches 43.22 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 618 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (618 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-60-235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### US Solar USS-QCMI3-60-235 8 kW Residential Fit

Needs 35 modules (618 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-M235.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI3-60-235 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### Why is US Solar USS-QCMI3-60-235 PTC wattage (211.3 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 211.3 W PTC (89.9% retention) across US Solar USS-QCMI3-60-235's 1.64 m2 aperture.

### Who should skip US Solar USS-QCMI3-60-235 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 US Solar USS-QCMI3-60-235 panels (618 sq ft) leave unusable roof gaps vs. Advance Power API-M235.

### What is the 1,000 V commercial string limit for US Solar USS-QCMI3-60-235?

On 1,000 V commercial inverters at -10 C (41.95 V cold Voc), US Solar USS-QCMI3-60-235 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting US Solar USS-QCMI3-60-235.

## Related Pages

Compare US Solar equipment, Advance Power API-M235 specs, utility payback rates, and NEC string calculators alongside US Solar USS-QCMI3-60-235.

[All US Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/us-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From US Solar

- [All US Solar Specs](https://epri-peac.com/solar-equipment/brands/us-solar/)
- [US Solar USS-QCMI3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-330/)
- [US Solar USS-QCMO3-72-330](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-330/)
- [US Solar USS-QCMI3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi3-72-310/)
- [US Solar USS-QCMO3-72-310](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmo3-72-310/)
- [US Solar USS-QCMI2-72-305](https://epri-peac.com/solar-equipment/modules/us-solar/us-solar-uss-qcmi2-72-305/)