title: "United Renewable Energy Co Ltd Specs (435.0W, 38.63V Voc)"
url: https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf435bfg-bb/
description: "CEC datasheet for United Renewable Energy Co Ltd FBF435BFG-BB: 435.0W STC, 38.63V Voc, 19-panel 8kW sizing, and NEC 690.7 limits."
---

CEC PV Module

# United Renewable Energy Co Ltd FBF435BFG-BB — CEC Solar Module Specifications

Manufacturer: [**United Renewable Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

United Renewable Energy Co Ltd FBF435BFG-BB is a 435.0 W STC (410.3 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.31% efficiency, 38.63 V Voc at 25 C, and 41.89 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 435.0 W

- **PTC Wattage** : 410.3 W

- **Voc @ 25C** : 38.63 V

- **Efficiency** : 22.31%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does United Renewable Energy Co Ltd FBF435BFG-BB Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd FBF435BFG-BB handles rooftop heat (410.3 W PTC), 8 kW sizing, and cold winter string voltage.

United Renewable Energy Co Ltd builds the United Renewable Energy Co Ltd FBF435BFG-BB (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). Compared against CertainTeed CTTC435HC12-08 (435.0 W), this model holds strong 94.3% PTC-to-STC heat retention (#3,231 of 21,677). Lower 38.63 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 22.31 A overcurrent floor served by a 25 A breaker.

## Where Does United Renewable Energy Co Ltd FBF435BFG-BB Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd FBF435BFG-BB (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define United Renewable Energy Co Ltd FBF435BFG-BB?

Percentile placement of United Renewable Energy Co Ltd FBF435BFG-BB across power density (223.1 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for United Renewable Energy Co Ltd FBF435BFG-BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd FBF435BFG-BB specifications.

Rank #6,850 / 21,677

### Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,379

### 22.31% Aperture Efficiency

Power density 223.1 W/m2 (2.40 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.89 V at -10 C (586.5 V string) and 42.82 V at -20 C (14 max).

 8 kW Reference Array

### 19 Panels = 8,265 W STC

Occupies 37.0 m2 (399 sq ft) producing 7,796 W PTC; NEC 690.8 OCPD floor is 22.31 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.63 * (1 + (-0.241/100) * (-10 - 25)) = 41.89 V | OCPD = 1.56 * 14.3 = 22.31 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd FBF435BFG-BB: Voc=38.63 V, beta_Voc=-0.241%/C, Isc=14.3 A, STC=435.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (586.5 V); 19 panels for 8 kW (399 sq ft).

## What Are the Published CEC Specifications for United Renewable Energy Co Ltd FBF435BFG-BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd FBF435BFG-BB.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd FBF435BFG-BB.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 410.3 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 38.63 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 14.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.06 V / 13.57 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.241 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 22.31% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many United Renewable Energy Co Ltd FBF435BFG-BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd FBF435BFG-BB (435.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 14 | 6.09 kW | 294 sq ft | $1,524 | $2,577 |
| **8 kW Class** | 19 | 8.27 kW | 399 sq ft | $2,070 | $3,500 |
| **10 kW Class** | 23 | 10.01 kW | 483 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd FBF435BFG-BB architecture.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd FBF435BFG-BB wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **United Renewable Energy Co Ltd FBF425BFG-BB** | 425.0 W | 400.6 W | 38.4 V | 31.72 V | 21.79% |
| **United Renewable Energy Co Ltd FBF430BFG-BB** | 430.0 W | 405.5 W | 38.5 V | 31.89 V | 22.05% |
| **United Renewable Energy Co Ltd FBF435BFG-BB** | 435.0 W | 410.3 W | 38.63 V | 32.06 V | 22.31% |
| **United Renewable Energy Co Ltd FBF440BFG-BB** | 440.0 W | 415.1 W | 38.79 V | 32.26 V | 22.56% |

## How Many United Renewable Energy Co Ltd FBF435BFG-BB Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd FBF435BFG-BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.63V and beta_Voc=-0.241%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.82 V | 14 panels | 599.5 V | 23 panels |
| **-10 C (14 F)** | 41.89 V | 14 panels | 586.5 V | 23 panels |
| **0 C (32 F)** | 40.96 V | 14 panels | 573.4 V | 24 panels |
| **25 C (77 F STC)** | 38.63 V | 15 panels | 579.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd FBF435BFG-BB?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd FBF435BFG-BB (435.0 W), including CertainTeed CTTC435HC12-08.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CertainTeed CTTC435HC12-08**](https://epri-peac.com/solar-equipment/modules/certainteed/certainteed-cttc435hc12-08/) CertainTeed | 435.0 W | Tie (0 W) | 38.5 V | 22.31% | 94.8% |
| [**Aptos Solar Technology LLC DNA-108-BFN10-435W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-108-bfn10-435w-dg/) Aptos Solar Technology LLC | 435.0 W | Tie (0 W) | 39.0 V | 22.42% | 94.9% |
| [**AMPS Solar AMPS-435N-108BB**](https://epri-peac.com/solar-equipment/modules/amps-solar/amps-solar-amps-435n-108bb/) AMPS Solar | 435.0 W | Tie (0 W) | 39.69 V | 22.42% | 95.1% |
| [**Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-430-h-hc-bf/) Boviet Solar Technology Co Ltd | 430.0 W | -5.0 W | 39.04 V | 19.91% | 94.8% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd FBF435BFG-BB?

Evaluate United Renewable Energy Co Ltd FBF435BFG-BB (435.0 W STC, 38.63 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd FBF435BFG-BB reaches 42.82 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd FBF435BFG-BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### United Renewable Energy Co Ltd FBF435BFG-BB 8 kW Residential Fit

Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTTC435HC12-08.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 410.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd FBF435BFG-BB by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for United Renewable Energy Co Ltd FBF435BFG-BB?

Multiplying United Renewable Energy Co Ltd FBF435BFG-BB's 14.3 A short-circuit current by 1.56 equals 22.31 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can United Renewable Energy Co Ltd FBF435BFG-BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.89 V cold Voc at 14 F and handles 14.3 A Isc; string inverters cap United Renewable Energy Co Ltd FBF435BFG-BB at 14 panels on 600 V.

### Is United Renewable Energy Co Ltd FBF435BFG-BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of United Renewable Energy Co Ltd FBF435BFG-BB rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

## Related Pages

Compare United Renewable Energy Co Ltd equipment, CertainTeed CTTC435HC12-08 specs, utility payback rates, and NEC string calculators alongside United Renewable Energy Co Ltd FBF435BFG-BB.

[All United Renewable Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From United Renewable Energy Co Ltd

- [All United Renewable Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/)
- [United Renewable Energy Co Ltd FBF590B8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf590b8g/)
- [United Renewable Energy Co Ltd FBF575D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf575d8g/)
- [United Renewable Energy Co Ltd FBF560B8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf560b8g/)
- [United Renewable Energy Co Ltd FBF560D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf560d8g/)
- [United Renewable Energy Co Ltd FBK555D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbk555d8g/)