# United Renewable Energy Co Ltd FBF415BFG — CEC Solar Module Specifications

Manufacturer: [**United Renewable Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

United Renewable Energy Co Ltd FBF415BFG is a 415.0 W STC (391.0 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 37.9 V Voc at 25 C, and 41.1 V cold Voc at -10 C (14 panels max per 600 V string).

- **STC Wattage** : 415.0 W

- **PTC Wattage** : 391.0 W

- **Voc @ 25C** : 37.9 V

- **Efficiency** : 21.28%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does United Renewable Energy Co Ltd FBF415BFG Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd FBF415BFG (Mono-c-Si) residential solar systems.

United Renewable Energy Co Ltd FBF415BFG delivers 212.8 W/m2 (1.37 percentage points above 19.91% CEC median) and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 42.01 V per unit, capping 600 V circuits at 14 panels. Compare specs directly with Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF (415.0 W).

## Where Does United Renewable Energy Co Ltd FBF415BFG Fall Across Listed CEC Models?

Comparison of United Renewable Energy Co Ltd FBF415BFG (415.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

## What Dataset Percentiles Define United Renewable Energy Co Ltd FBF415BFG?

Relative ranking of United Renewable Energy Co Ltd FBF415BFG across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.

## What Do the Dataset Ranks Show for United Renewable Energy Co Ltd FBF415BFG?

Summary of United Renewable Energy Co Ltd FBF415BFG output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,199 / 21,677

### Top 39.4% STC Output

415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,257

### 21.28% Aperture Efficiency

Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

### 14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.1 V at -10 C (575.4 V string) and 42.01 V at -20 C (14 max).

 8 kW Reference Array

### 20 Panels = 8,300 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,820 W PTC; NEC 690.8 OCPD floor is 21.82 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.9 * (1 + (-0.241/100) * (-10 - 25)) = 41.1 V | OCPD = 1.56 * 13.99 = 21.82 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd FBF415BFG: Voc=37.9 V, beta_Voc=-0.241%/C, Isc=13.99 A, STC=415.0 W, Area=1.95 m2.

**Result:** 14 panels max on 600 V (575.4 V); 20 panels for 8 kW (420 sq ft).

## What Are the Published CEC Specifications for United Renewable Energy Co Ltd FBF415BFG?

Complete CEC test sheet for United Renewable Energy Co Ltd FBF415BFG including Isc (13.99 A), Voc (37.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd FBF415BFG.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 391.0 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 37.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 31.3 V / 13.24 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.241 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 21.28% (1.95 m2) | Array roof footprint density |
| **Cell Count & Technology** | 54 cells (Mono-c-Si) | Bifacial glass-glass |

## How Many United Renewable Energy Co Ltd FBF415BFG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd FBF415BFG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 15 | 6.22 kW | 315 sq ft | $1,557 | $2,632 |
| **8 kW Class** | 20 | 8.3 kW | 420 sq ft | $2,077 | $3,513 |
| **10 kW Class** | 25 | 10.38 kW | 525 sq ft | $2,598 | $4,393 |

## Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

Related United Renewable Energy Co Ltd power steps and black/silver trims consolidated into this United Renewable Energy Co Ltd FBF415BFG series guide.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd FBF415BFG wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **United Renewable Energy Co Ltd FBF405BFG** | 405.0 W | 381.4 W | 37.7 V | 31.0 V | 20.77% |
| **United Renewable Energy Co Ltd FBF410BFG** | 410.0 W | 386.2 W | 37.8 V | 31.1 V | 21.03% |
| **United Renewable Energy Co Ltd FBF415BFG** | 415.0 W | 391.0 W | 37.9 V | 31.3 V | 21.28% |
| **United Renewable Energy Co Ltd FBF420BFG** | 420.0 W | 395.8 W | 38.1 V | 31.5 V | 21.54% |

## How Many United Renewable Energy Co Ltd FBF415BFG Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for United Renewable Energy Co Ltd FBF415BFG (37.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.9V and beta_Voc=-0.241%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 42.01 V | 14 panels | 588.1 V | 23 panels |
| **-10 C (14 F)** | 41.1 V | 14 panels | 575.4 V | 24 panels |
| **0 C (32 F)** | 40.18 V | 14 panels | 562.5 V | 24 panels |
| **25 C (77 F STC)** | 37.9 V | 15 panels | 568.5 V | 26 panels |

## Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd FBF415BFG?

Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF (415.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-415-h-hc-bf/) Boviet Solar Technology Co Ltd | 415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| [**Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF-DG**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm7609m-415-h-hc-bf-dg/) Boviet Solar Technology Co Ltd | 415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| [**CSI Solar Co Ltd CS6R-410MB**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb/) CSI Solar Co Ltd | 410.0 W | -5.0 W | 38.0 V | 21.69% | 94.2% |
| [**CSI Solar Co Ltd CS6R-410MB-HL**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs6r-410mb-hl/) CSI Solar Co Ltd | 410.0 W | -5.0 W | 38.0 V | 21.69% | 94.2% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd FBF415BFG?

Evaluate United Renewable Energy Co Ltd FBF415BFG (415.0 W STC, 37.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd FBF415BFG reaches 42.01 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd FBF415BFG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### United Renewable Energy Co Ltd FBF415BFG 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF.

### Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 391.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd FBF415BFG by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### How many United Renewable Energy Co Ltd FBF415BFG panels fit on a 600 V winter solar string?

At -10 C (14 F), United Renewable Energy Co Ltd FBF415BFG cold Voc rises from 37.9 V to 41.1 V (beta_Voc -0.241%/C), capping a 600 V string at 14 panels (575.4 V).

### How much roof area does an 8 kW array of United Renewable Energy Co Ltd FBF415BFG need?

An 8 kW DC system uses 20 United Renewable Energy Co Ltd FBF415BFG modules (8,300 W STC / 7,820 W PTC), covering roughly 420 sq ft and saving ~$2,077/yr at 18.54 c/kWh.

### How does United Renewable Energy Co Ltd FBF415BFG compare against Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF?

United Renewable Energy Co Ltd FBF415BFG outputs 415.0 W STC (37.9 V Voc, rank #8,199 of 21,677), while Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF delivers 415.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare United Renewable Energy Co Ltd equipment, Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF specs, utility payback rates, and NEC string calculators alongside United Renewable Energy Co Ltd FBF415BFG.

[All United Renewable Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From United Renewable Energy Co Ltd

- [All United Renewable Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/)
- [United Renewable Energy Co Ltd FBF590B8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf590b8g/)
- [United Renewable Energy Co Ltd FBF575D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf575d8g/)
- [United Renewable Energy Co Ltd FBF560B8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf560b8g/)
- [United Renewable Energy Co Ltd FBF560D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf560d8g/)
- [United Renewable Energy Co Ltd FBK555D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbk555d8g/)