title: "United Renewable Energy Co Ltd Specs (310.0W, 39.9V Voc)"
url: https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-f6k310h3f/
description: "CEC datasheet for United Renewable Energy Co Ltd F6K310H3F: 310.0W STC, 39.9V Voc, 26-panel 8kW sizing, and NEC 690.7 limits. Source-verified US engineering data."
---

CEC PV Module

# United Renewable Energy Co Ltd F6K310H3F — CEC Solar Module Specifications

Manufacturer: [**United Renewable Energy Co Ltd**](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/) Registry: **CEC Verified Engineering Specification**

United Renewable Energy Co Ltd F6K310H3F is a 310.0 W STC (285.0 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.25% efficiency, 39.9 V Voc at 25 C, and 44.26 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 310.0 W

- **PTC Wattage** : 285.0 W

- **Voc @ 25C** : 39.9 V

- **Efficiency** : 19.25%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does United Renewable Energy Co Ltd F6K310H3F Compare Against Peer CEC Listings?

Solar engineering breakdown for United Renewable Energy Co Ltd F6K310H3F: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 310.0 W STC and 285.0 W PTC, United Renewable Energy Co Ltd F6K310H3F sits -75.0 W vs all-CEC median (below all-CEC median; higher than 25.6% of peers) among 21,677 listed modules. Power density reaches 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). Lower 39.9 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer GCL System Integration Technology Co Ltd GCL-M6/60310 rates 310.0 W.

## Where Does United Renewable Energy Co Ltd F6K310H3F Fall Across Listed CEC Models?

Distribution marker showing United Renewable Energy Co Ltd F6K310H3F (310.0 W) relative to the 385.0 W all-CEC solar panel median.

## What Dataset Percentiles Define United Renewable Energy Co Ltd F6K310H3F?

Dataset percentiles tracking United Renewable Energy Co Ltd F6K310H3F power output, thermal retention ratio, and aperture efficiency against 21,677 models.

## What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F6K310H3F?

Benchmark highlights for United Renewable Energy Co Ltd F6K310H3F covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,760 / 21,677

### 310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,863

### 19.25% Aperture Efficiency

Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.26 V at -10 C (575.4 V string) and 45.5 V at -20 C (13 max).

 8 kW Reference Array

### 26 Panels = 8,060 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,410 W PTC; NEC 690.8 OCPD floor is 15.44 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.9 * (1 + (-0.312/100) * (-10 - 25)) = 44.26 V | OCPD = 1.56 * 9.9 = 15.44 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F6K310H3F: Voc=39.9 V, beta_Voc=-0.312%/C, Isc=9.9 A, STC=310.0 W, Area=1.61 m2.

**Result:** 13 panels max on 600 V (575.4 V); 26 panels for 8 kW (451 sq ft).

## What Are the Published CEC Specifications for United Renewable Energy Co Ltd F6K310H3F?

Official CEC datasheet figures for United Renewable Energy Co Ltd F6K310H3F (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd F6K310H3F.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 285.0 W (91.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 39.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 9.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 32.9 V / 9.43 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.312 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 19.25% (1.61 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many United Renewable Energy Co Ltd F6K310H3F Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many United Renewable Energy Co Ltd F6K310H3F modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 20 | 6.2 kW | 347 sq ft | $1,552 | $2,624 |
| **8 kW Class** | 26 | 8.06 kW | 451 sq ft | $2,017 | $3,411 |
| **10 kW Class** | 33 | 10.23 kW | 572 sq ft | $2,560 | $4,330 |

## Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

Consolidated United Renewable Energy Co Ltd wattage variants sharing the United Renewable Energy Co Ltd F6K310H3F mechanical and cell layout.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd F6K310H3F wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **United Renewable Energy Co Ltd F6K300H3F** | 300.0 W | 275.6 W | 39.7 V | 32.7 V | 18.63% |
| **United Renewable Energy Co Ltd F6K305H3F** | 305.0 W | 280.3 W | 39.8 V | 32.8 V | 18.94% |
| **United Renewable Energy Co Ltd F6K310H3F** | 310.0 W | 285.0 W | 39.9 V | 32.9 V | 19.25% |
| **United Renewable Energy Co Ltd F6K315H3F** | 315.0 W | 289.8 W | 40.0 V | 33.0 V | 19.57% |

## How Many United Renewable Energy Co Ltd F6K310H3F Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on United Renewable Energy Co Ltd F6K310H3F (44.26 V at 14 F).

Computed from Voc=39.9V and beta_Voc=-0.312%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 45.5 V | 13 panels | 591.5 V | 21 panels |
| **-10 C (14 F)** | 44.26 V | 13 panels | 575.4 V | 22 panels |
| **0 C (32 F)** | 43.01 V | 13 panels | 559.1 V | 23 panels |
| **25 C (77 F STC)** | 39.9 V | 15 panels | 598.5 V | 25 panels |

## Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F6K310H3F?

Competing CEC solar panels closest to United Renewable Energy Co Ltd F6K310H3F in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**GCL System Integration Technology Co Ltd GCL-M6/60310**](https://epri-peac.com/solar-equipment/modules/gcl-system-integration-technology-co-ltd/gcl-system-integration-technology-co-ltd-gcl-m6-60310/) GCL System Integration Technology Co Ltd | 310.0 W | Tie (0 W) | 39.9 V | 19.02% | 91.3% |
| [**CSI Solar Co Ltd CS3K-310MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3k-310ms/) CSI Solar Co Ltd | 310.0 W | Tie (0 W) | 39.7 V | 19.34% | 93.1% |
| [**Boviet Solar Technology Co Ltd BVM6610M-310**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-310/) Boviet Solar Technology Co Ltd | 310.0 W | Tie (0 W) | 40.1 V | 19.05% | 92.2% |
| [**Boviet Solar Technology Co Ltd BVM6610M-310-H**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-310-h/) Boviet Solar Technology Co Ltd | 310.0 W | Tie (0 W) | 40.1 V | 19.02% | 93.1% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F6K310H3F?

Evaluate United Renewable Energy Co Ltd F6K310H3F (310.0 W STC, 39.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F6K310H3F reaches 45.5 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (451 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F6K310H3F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### United Renewable Energy Co Ltd F6K310H3F 8 kW Residential Fit

Needs 26 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60310.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 285.0 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd F6K310H3F by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

### How many United Renewable Energy Co Ltd F6K310H3F panels fit on a 600 V winter solar string?

At -10 C (14 F), United Renewable Energy Co Ltd F6K310H3F cold Voc rises from 39.9 V to 44.26 V (beta_Voc -0.312%/C), capping a 600 V string at 13 panels (575.4 V).

### How much roof area does an 8 kW array of United Renewable Energy Co Ltd F6K310H3F need?

An 8 kW DC system uses 26 United Renewable Energy Co Ltd F6K310H3F modules (8,060 W STC / 7,410 W PTC), covering roughly 451 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

### How does United Renewable Energy Co Ltd F6K310H3F compare against GCL System Integration Technology Co Ltd GCL-M6/60310?

United Renewable Energy Co Ltd F6K310H3F outputs 310.0 W STC (39.9 V Voc, rank #15,760 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

## Related Pages

Compare United Renewable Energy Co Ltd equipment, GCL System Integration Technology Co Ltd GCL-M6/60310 specs, utility payback rates, and NEC string calculators alongside United Renewable Energy Co Ltd F6K310H3F.

[All United Renewable Energy Co Ltd Certified Solar Models](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From United Renewable Energy Co Ltd

- [All United Renewable Energy Co Ltd Specs](https://epri-peac.com/solar-equipment/brands/united-renewable-energy-co-ltd/)
- [United Renewable Energy Co Ltd FBF590B8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf590b8g/)
- [United Renewable Energy Co Ltd FBF575D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf575d8g/)
- [United Renewable Energy Co Ltd FBF560B8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf560b8g/)
- [United Renewable Energy Co Ltd FBF560D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbf560d8g/)
- [United Renewable Energy Co Ltd FBK555D8G](https://epri-peac.com/solar-equipment/modules/united-renewable-energy-co-ltd/united-renewable-energy-co-ltd-fbk555d8g/)