title: "Trina Solar TSM-470DE15V(II) Specs (470.0W, 43.0V Voc)"
url: https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-470de15v-ii/
description: "CEC datasheet for Trina Solar TSM-470DE15V(II): 470.0W STC, 43.0V Voc, 18-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Trina Solar TSM-470DE15V(II) — CEC Solar Module Specifications

Manufacturer: [**Trina Solar**](https://epri-peac.com/solar-equipment/brands/trina-solar/) Registry: **CEC Verified Engineering Specification**

Trina Solar TSM-470DE15V(II) is a 470.0 W STC (439.4 W PTC) Mono-c-Si solar module ranking #4,967 of 21,677 CEC listings (top 23.4%; higher than 76.6% of peers). It delivers 20.17% efficiency, 43.0 V Voc at 25 C, and 47.14 V cold Voc at -10 C (12 panels max per 600 V string).

- **STC Wattage** : 470.0 W

- **PTC Wattage** : 439.4 W

- **Voc @ 25C** : 43.0 V

- **Efficiency** : 20.17%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trina Solar TSM-470DE15V(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-470DE15V(II) handles rooftop heat (439.4 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-470DE15V(II) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-120-BFN10-470W-DG (470.0 W), this model holds strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677). Mid-range 43.0 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.42 A overcurrent floor served by a 25 A breaker.

## Where Does Trina Solar TSM-470DE15V(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-470DE15V(II) (470.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Trina Solar TSM-470DE15V(II)?

Percentile placement of Trina Solar TSM-470DE15V(II) across power density (201.7 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Trina Solar TSM-470DE15V(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-470DE15V(II) specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #4,967 / 21,677

### Top 23.4% STC Output

470.0 W STC (+85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,881

### 20.17% Aperture Efficiency

Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

### 12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.14 V at -10 C (565.7 V string) and 48.32 V at -20 C (12 max).

 8 kW Reference Array

### 18 Panels = 8,460 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,909 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.0 * (1 + (-0.275/100) * (-10 - 25)) = 47.14 V | OCPD = 1.56 * 13.73 = 21.42 A

Inputs from CEC Modules.csv for Trina Solar TSM-470DE15V(II): Voc=43.0 V, beta_Voc=-0.275%/C, Isc=13.73 A, STC=470.0 W, Area=2.33 m2.

**Result:** 12 panels max on 600 V (565.7 V); 18 panels for 8 kW (451 sq ft).

## What Are the Published CEC Specifications for Trina Solar TSM-470DE15V(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-470DE15V(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-470DE15V(II).

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 470.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 439.4 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 43.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 36.1 V / 13.02 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.275 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.17% (2.33 m2) | Array roof footprint density |
| **Cell Count & Technology** | 126 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Trina Solar TSM-470DE15V(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-470DE15V(II) (470.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 13 | 6.11 kW | 326 sq ft | $1,529 | $2,586 |
| **8 kW Class** | 18 | 8.46 kW | 451 sq ft | $2,117 | $3,580 |
| **10 kW Class** | 22 | 10.34 kW | 552 sq ft | $2,588 | $4,376 |

## How Many Trina Solar TSM-470DE15V(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-470DE15V(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.0V and beta_Voc=-0.275%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 48.32 V | 12 panels | 579.8 V | 20 panels |
| **-10 C (14 F)** | 47.14 V | 12 panels | 565.7 V | 21 panels |
| **0 C (32 F)** | 45.96 V | 13 panels | 597.5 V | 21 panels |
| **25 C (77 F STC)** | 43.0 V | 13 panels | 559.0 V | 23 panels |

## Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-470DE15V(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-470DE15V(II) (470.0 W), including Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**Aptos Solar Technology LLC DNA-120-BFN10-470W-DG**](https://epri-peac.com/solar-equipment/modules/aptos-solar-technology-llc/aptos-solar-technology-llc-dna-120-bfn10-470w-dg/) Aptos Solar Technology LLC | 470.0 W | Tie (0 W) | 42.38 V | 21.76% | 94.9% |
| [**Auxin Solar AXN10M470W**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m470w/) Auxin Solar | 470.0 W | Tie (0 W) | 43.78 V | 21.86% | 92.0% |
| [**CSI Solar Co Ltd CS61-60TM-470H**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs61-60tm-470h/) CSI Solar Co Ltd | 470.0 W | Tie (0 W) | 42.0 V | 21.46% | 94.6% |
| [**Auxin Solar AXN10M465B**](https://epri-peac.com/solar-equipment/modules/auxin-solar/auxin-solar-axn10m465b/) Auxin Solar | 465.0 W | -5.0 W | 43.72 V | 21.63% | 91.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-470DE15V(II)?

Evaluate Trina Solar TSM-470DE15V(II) (470.0 W STC, 43.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-470DE15V(II) reaches 48.32 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 451 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (451 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-470DE15V(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Trina Solar TSM-470DE15V(II) 8 kW Residential Fit

Needs 18 modules (451 sq ft) with a 25 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BFN10-470W-DG.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 439.4 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-470DE15V(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-470DE15V(II)?

Multiplying Trina Solar TSM-470DE15V(II)'s 13.73 A short-circuit current by 1.56 equals 21.42 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

### Can Trina Solar TSM-470DE15V(II) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.14 V cold Voc at 14 F and handles 13.73 A Isc; string inverters cap Trina Solar TSM-470DE15V(II) at 12 panels on 600 V.

### Is Trina Solar TSM-470DE15V(II) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-470DE15V(II) rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

## Related Pages

Compare Trina Solar equipment, Aptos Solar Technology LLC DNA-120-BFN10-470W-DG specs, utility payback rates, and NEC string calculators alongside Trina Solar TSM-470DE15V(II).

[All Trina Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/trina-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trina Solar

- [All Trina Solar Specs](https://epri-peac.com/solar-equipment/brands/trina-solar/)
- [Trina Solar TSM-740NEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/)
- [Trina Solar TSM-660DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660de21/)
- [Trina Solar TSM-660DEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660deg21c20/)
- [Trina Solar TSM-650NEG19RC20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-650neg19rc20/)
- [Trina Solar TSM-645DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-645de21/)