title: "Trina Solar TSM-385DE0905 Specs (385.0W, 40.6V Voc)"
url: https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-385de0905/
description: "CEC datasheet for Trina Solar TSM-385DE0905: 385.0W STC, 40.6V Voc, 21-panel 8kW sizing, and NEC 690.7 limits. Verified US government and CEC engineering data."
---

CEC PV Module

# Trina Solar TSM-385DE0905 — CEC Solar Module Specifications

Manufacturer: [**Trina Solar**](https://epri-peac.com/solar-equipment/brands/trina-solar/) Registry: **CEC Verified Engineering Specification**

Trina Solar TSM-385DE0905 is a 385.0 W STC (362.3 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 20.16% efficiency, 40.6 V Voc at 25 C, and 43.97 V cold Voc at -10 C (13 panels max per 600 V string).

- **STC Wattage** : 385.0 W

- **PTC Wattage** : 362.3 W

- **Voc @ 25C** : 40.6 V

- **Efficiency** : 20.16%

Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

## How Does Trina Solar TSM-385DE0905 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-385DE0905 handles rooftop heat (362.3 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-385DE0905 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS3L-385MS (385.0 W), this model holds strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Mid-range 40.6 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 18.83 A overcurrent floor served by a 20 A breaker.

## Where Does Trina Solar TSM-385DE0905 Fall Across Listed CEC Models?

Where Trina Solar TSM-385DE0905 (385.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

## What Dataset Percentiles Define Trina Solar TSM-385DE0905?

Percentile placement of Trina Solar TSM-385DE0905 across power density (201.6 W/m2), thermal retention, and nameplate STC wattage.

## What Do the Dataset Ranks Show for Trina Solar TSM-385DE0905?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-385DE0905 specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #10,723 / 21,677

### 385.0 W STC · Higher Than 49.1%

385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,907

### 20.16% Aperture Efficiency

Power density 201.6 W/m2 (0.25 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

### 13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.97 V at -10 C (571.6 V string) and 44.93 V at -20 C (13 max).

 8 kW Reference Array

### 21 Panels = 8,085 W STC

Occupies 40.1 m2 (432 sq ft) producing 7,608 W PTC; NEC 690.8 OCPD floor is 18.83 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.6 * (1 + (-0.237/100) * (-10 - 25)) = 43.97 V | OCPD = 1.56 * 12.07 = 18.83 A

Inputs from CEC Modules.csv for Trina Solar TSM-385DE0905: Voc=40.6 V, beta_Voc=-0.237%/C, Isc=12.07 A, STC=385.0 W, Area=1.91 m2.

**Result:** 13 panels max on 600 V (571.6 V); 21 panels for 8 kW (432 sq ft).

## What Are the Published CEC Specifications for Trina Solar TSM-385DE0905?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-385DE0905.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-385DE0905.

| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| **Nameplate Power (STC)** | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| **Real-World Output (PTC)** | 362.3 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| **Open-Circuit Voltage (Voc)** | 40.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| **Short-Circuit Current (Isc)** | 12.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| **Max Power Voltage / Current** | 33.6 V / 11.46 A | Inverter MPPT operating window alignment |
| **Voc Temp Coefficient (beta_Voc)** | -0.237 %/C | Negative slope governing voltage rise below 25C |
| **Module Efficiency & Area** | 20.16% (1.91 m2) | Array roof footprint density |
| **Cell Count & Technology** | 60 cells (Mono-c-Si) | Monofacial backsheet |

## How Many Trina Solar TSM-385DE0905 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-385DE0905 (385.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).

| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| **6 kW Class** | 16 | 6.16 kW | 329 sq ft | $1,542 | $2,607 |
| **8 kW Class** | 21 | 8.09 kW | 432 sq ft | $2,025 | $3,424 |
| **10 kW Class** | 26 | 10.01 kW | 535 sq ft | $2,505 | $4,236 |

## Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-385DE0905 architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Trina Solar TSM-385DE0905 wattage tier to avoid duplicate 5W/trim datasheets.

| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| **Trina Solar TSM-375DE0905** | 375.0 W | 352.7 W | 40.2 V | 33.2 V | 19.63% |
| **Trina Solar TSM-380DE0905** | 380.0 W | 357.5 W | 40.4 V | 33.4 V | 19.9% |
| **Trina Solar TSM-385DE0905** | 385.0 W | 362.3 W | 40.6 V | 33.6 V | 20.16% |
| **Trina Solar TSM-390DE0905** | 390.0 W | 367.1 W | 40.8 V | 33.8 V | 20.42% |
| **Trina Solar TSM-395DE0905** | 395.0 W | 372.0 W | 41.0 V | 34.0 V | 20.68% |

## How Many Trina Solar TSM-385DE0905 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-385DE0905 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.6V and beta_Voc=-0.237%/C across design ambient temperatures.

| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| **-20 C (-4 F)** | 44.93 V | 13 panels | 584.1 V | 22 panels |
| **-10 C (14 F)** | 43.97 V | 13 panels | 571.6 V | 22 panels |
| **0 C (32 F)** | 43.01 V | 13 panels | 559.1 V | 23 panels |
| **25 C (77 F STC)** | 40.6 V | 14 panels | 568.4 V | 24 panels |

## Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-385DE0905?

Alternative CEC solar modules from competing brands near Trina Solar TSM-385DE0905 (385.0 W), including CSI Solar Co Ltd CS3L-385MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.

| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| [**CSI Solar Co Ltd CS3L-385MS**](https://epri-peac.com/solar-equipment/modules/csi-solar-co-ltd/csi-solar-co-ltd-cs3l-385ms/) CSI Solar Co Ltd | 385.0 W | Tie (0 W) | 41.4 V | 21.51% | 93.2% |
| [**Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC**](https://epri-peac.com/solar-equipment/modules/boviet-solar-technology-co-ltd/boviet-solar-technology-co-ltd-bvm6610m-380s-h-hc/) Boviet Solar Technology Co Ltd | 380.0 W | -5.0 W | 40.94 V | 20.54% | 94.2% |
| [**DualSun SAS DualSun 380M-120-01**](https://epri-peac.com/solar-equipment/modules/dualsun-sas/dualsun-sas-dualsun-380m-120-01/) DualSun SAS | 380.0 W | -5.0 W | 41.3 V | 21.47% | 93.9% |
| [**Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W**](https://epri-peac.com/solar-equipment/modules/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd/amerisolar-worldwide-energy-and-manufacturing-usa-co-ltd-as-6m120-bhc-375w/) Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd | 375.0 W | -10.0 W | 41.1 V | 21.07% | 92.6% |

What to Check & Best-Fit Scenarios

## What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-385DE0905?

Evaluate Trina Solar TSM-385DE0905 (385.0 W STC, 40.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-385DE0905 reaches 44.93 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 432 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (432 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-385DE0905 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

### Trina Solar TSM-385DE0905 8 kW Residential Fit

Needs 21 modules (432 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

### Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-385MS.

### Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 362.3 W PTC.

## Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-385DE0905 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

### What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-385DE0905?

Multiplying Trina Solar TSM-385DE0905's 12.07 A short-circuit current by 1.56 equals 18.83 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

### Can Trina Solar TSM-385DE0905 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.97 V cold Voc at 14 F and handles 12.07 A Isc; string inverters cap Trina Solar TSM-385DE0905 at 13 panels on 600 V.

### Is Trina Solar TSM-385DE0905 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-385DE0905 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

## Related Pages

Compare Trina Solar equipment, CSI Solar Co Ltd CS3L-385MS specs, utility payback rates, and NEC string calculators alongside Trina Solar TSM-385DE0905.

[All Trina Solar Certified Solar Models](https://epri-peac.com/solar-equipment/brands/trina-solar/) [Browse All CEC Solar Modules & Inverters](https://epri-peac.com/solar-equipment/) [Run NEC 690.7 Cold-Temp PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [Check NEC 705.12 120% Panel Busbar Backfeed Limit](https://epri-peac.com/tools/solar-busbar-120/)

## Sources

1. [CEC Solar Equipment List — PV Modules (NREL SAM Distribution)](https://raw.githubusercontent.com/NREL/SAM/develop/deploy/libraries/CEC%20Modules.csv) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
2. [NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only)](https://www.nfpa.org/codes-and-standards/nfpa-70-standard-development/70) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Spec Sheet Sections

- Dataset Ranks & Thresholds
- CEC Electrical Table
- 6-10 kW Array Sizing
- Alternative Peers
- Engineering FAQ
- Official Sources

Interactive NEC Tools

Run custom cold-temp string Voc or 120% panel busbar checks for this hardware.
[PV String Voc Calculator](https://epri-peac.com/tools/pv-string-voc/) [120% Busbar Checker](https://epri-peac.com/tools/solar-busbar-120/)

More From Trina Solar

- [All Trina Solar Specs](https://epri-peac.com/solar-equipment/brands/trina-solar/)
- [Trina Solar TSM-740NEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-740neg21c20/)
- [Trina Solar TSM-660DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660de21/)
- [Trina Solar TSM-660DEG21C20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-660deg21c20/)
- [Trina Solar TSM-650NEG19RC20](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-650neg19rc20/)
- [Trina Solar TSM-645DE21](https://epri-peac.com/solar-equipment/modules/trina-solar/trina-solar-tsm-645de21/)